The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Subnormothermic Machine Perfusion for Ex Vivo Preservation and Recovery of the Human Liver for Transplantation
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
These other technologies extend preservation for broader organ sharing but only increase preservation by hours to a few days and do not achieve prolonged banking for months and potentially years.
“While these extend preservation for broader organ sharing, they only increase preservation by hours to a few days and do not achieve prolonged banking for months and potentially years.”
From Vitrification and nanowarming enable long-term organ cryopreservation and life-sustaining kidney transplantation in a rat model (2023) · cites this paper as [38]
A range of other technologies are in use or being studied to prolong preservation times for kidneys and other organs, including hypothermic machine perfusion, normothermic machine perfusion, subnormothermic machine perfusion, high subzero supercooling, and partial freezing.
“Further, a range of other technologies are in use or are being studied to prolong preservation times for kidneys and other organs, including hypothermic machine perfusion37, normothermic machine perfusion25, subnormothermic machine perfusion38, high subzero supercooling39,40, and partial freezing41.”
From Vitrification and nanowarming enable long-term organ cryopreservation and life-sustaining kidney transplantation in a rat model (2023) · cites this paper as [38]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhao, K., Zhao, G.-M., Wu, D., Soong, Y., Birk, A. V., Schiller, P. W., & Szeto, H. H. (2004) · Journal of Biological Chemistry · doi:10.1074/jbc.m402999200 · Cited by 782
Flagged first, then by citations
Research works printed but not linked: 49
- Jain, 2000, Long-term survival after liver transplantation in 4,000 consecutive patients at a single center, Ann Surg, 232, 490, 10.1097/00000658-200010000-00004 · DOI
- McCormack, 2007, Use of severely steatotic grafts in liver transplantation: A matched case–control study, Ann Surg, 246, 940, 10.1097/SLA.0b013e31815c2a3f · DOI
- Moore, 2005, Impact of donor, technical, and recipient risk factors on survival and quality of life after liver transplantation, Arch Surg, 140, 273, 10.1001/archsurg.140.3.273 · DOI
- de Vera, 2009, Liver transplantation using donation after cardiac death donors: Long-term follow-up from a single center, Am J Transplant, 9, 773, 10.1111/j.1600-6143.2009.02560.x · DOI
- de Rougemont, 2009, One hour hypothermic oxygenated perfusion (HOPE) protects nonviable liver allografts donated after cardiac death, Ann Surg, 250, 674, 10.1097/SLA.0b013e3181bcb1ee · DOI
- Bessems, 2005, Improved machine perfusion preservation of the non-heart-beating donor rat liver using polysol: A new machine perfusion preservation solution, Liver Transpl, 11, 1379, 10.1002/lt.20502 · DOI
- Monbaliu, 2012, Preserving morphology and evaluating quality of liver grafts by hypothermic machine perfusion, a proof of concept study using discarded human livers, Liver Transpl, 18, 1495, 10.1002/lt.23550 · DOI
- Schlegel, 2013, Hypothermic oxygenated perfusion (HOPE) protects from biliary injury in a rodent model of DCD liver transplantation, J Hepatol, 59, 984, 10.1016/j.jhep.2013.06.022 · DOI
- Guarrera, 2010, Hypothermic machine preservation in human liver transplantation: The first clinical series, Am J Transplant, 10, 372, 10.1111/j.1600-6143.2009.02932.x · DOI
- Dutkowski, 2014, HOPE for human liver grafts obtained from donors after cardiac death, J Hepatol, 60, 765, 10.1016/j.jhep.2013.11.023 · DOI
- Xu, 2011, Excorporeal normothermic machine perfusion resuscitates pig DCD livers with extended warm ischemia, J Surg Res, 43, 1484
- Perk, 2011, A metabolic index of ischemic injury for perfusion-recovery of cadaveric rat livers, PLoS ONE, 6, e28518, 10.1371/journal.pone.0028518 · DOI
- Perk, 2012, A fitness index for transplantation of machine-perfused cadaveric rat livers, BMC Res Notes, 5, 325, 10.1186/1756-0500-5-325 · DOI
- Op den Dries, 2013, Ex vivo normothermic machine perfusion and viability testing of discarded human donor livers, Am J Transplant, 13, 1327, 10.1111/ajt.12187 · DOI
- Minor, 2013, Controlled oxygenated rewarming of cold stored liver grafts by thermally graduated machine perfusion prior to reperfusion, Am J Transplant, 13, 1450, 10.1111/ajt.12235 · DOI
- Shigeta, 2013, Impact of rewarming preservation by continuous machine perfusion: Improved post-transplant recovery in pigs, Transplant Proc, 45, 1684, 10.1016/j.transproceed.2013.01.098 · DOI
- Vajdová, 2002, ATP-supplies in the cold-preserved liver: A long-neglected factor of organ viability, Hepatology, 36, 1543, 10.1002/hep.1840360633 · DOI
- Berendsen, 2012, A simplified subnormothermic machine perfusion system restores ischemically damaged liver grafts in a rat model of orthotopic liver transplantation, Transplant Res, 1, 6, 10.1186/2047-1440-1-6 · DOI
- Tolboom, 2007, A model for normothermic preservation of the rat liver, Tissue Eng, 13, 2143, 10.1089/ten.2007.0101 · DOI
- Lüer, 2010, Role of oxygen during hypothermic machine perfusion preservation of the liver, Transpl Int, 23, 944
- Mitchell, 1999, Energy metabolism following prolonged hepatic cold preservation: Benefits of interrupted hypoxia on the adenine nucleotide pool in rat liver, Cryobiology, 39, 130, 10.1006/cryo.1999.2191 · DOI
- McCord, 1985, Oxygen-derived free radicals in postischemic tissue injury, N Engl J Med, 312, 159, 10.1056/NEJM198501173120305 · DOI · Paper page
- Reddy, 2004, Preservation of porcine non-heart-beating donor livers by sequential cold storage and warm perfusion, Transplantation, 77, 1328, 10.1097/01.TP.0000119206.63326.56 · DOI
- Ferrigno, 2011, Machine perfusion at 20°C reduces preservation damage to livers from non-heart beating donors, Cryobiology, 62, 152, 10.1016/j.cryobiol.2011.02.004 · DOI
- Lanir, 1988, Hepatic transplantation survival: Correlation with adenine nucleotide level in donor liver, Hepatology, 8, 471, 10.1002/hep.1840080306 · DOI
- Kamiike, 1988, Adenine nucleotide metabolism and its relation to organ viability in human liver transplantation, Transplantation, 45, 138, 10.1097/00007890-198801000-00030 · DOI
- Usta, 2013, Supercooling as a viable non-freezing cell preservation method of rat hepatocytes, PLoS ONE, 8, e69334, 10.1371/journal.pone.0069334 · DOI
- Berendsen, 2011, Hepatocyte viability and adenosine triphosphate content decrease linearly over time during conventional cold storage of rat liver grafts, Transplant Proc, 43, 1484, 10.1016/j.transproceed.2010.12.066 · DOI
- Bruinsma, 2013, Determination and extension of the limits to static cold storage using subnormothermic machine perfusion, Int J Artif Organs, 36, 775, 10.5301/ijao.5000250 · DOI
- Minor, 2003, Fibrinolysis in organ procurement for transplantation after cardiocirculatory compromise, Thromb Haemost, 90, 361, 10.1055/s-0037-1613489 · DOI
- Koetting, 2011, Donation after cardiac death: Dynamic graft reconditioning during or after ischemic preservation?, Artif Organs, 35, 565, 10.1111/j.1525-1594.2010.01138.x · DOI
- St Peter, 2002, Extended preservation of non-heart-beating donor livers with normothermic machine perfusion, Br J Surg, 89, 609, 10.1046/j.1365-2168.2002.02052.x · DOI
- Butler, 2002, Successful extracorporeal porcine liver perfusion for 72 hr, Transplantation, 73, 1212, 10.1097/00007890-200204270-00005 · DOI
- Bessems, 2006, Machine perfusion preservation of the pig liver using a new preservation solution, polysol, Transplant Proc, 38, 1238, 10.1016/j.transproceed.2006.02.063 · DOI
- Reddy, 2005, Non-heart-beating donor porcine livers: The adverse effect of cooling, Liver Transpl, 11, 35, 10.1002/lt.20287 · DOI
- van der Plaats, 2006, The Groningen hypothermic liver perfusion pump: Functional evaluation of a new machine perfusion system, Ann Biomed Eng, 34, 1924, 10.1007/s10439-006-9207-4 · DOI
- Miyagi, 2008, The significance of preserving the energy status and microcirculation in liver grafts from non-heart-beating donor, Cell Transplant, 17, 173, 10.3727/000000008783906874 · DOI
- Friend, 2001, Normothermic perfusion of the isolated liver, Transplant Proc, 33, 3436, 10.1016/S0041-1345(01)02481-2 · DOI
- Vajdová, 2000, Cold-preservation-induced sensitivity of rat hepatocyte function to rewarming injury and its prevention by short-term reperfusion, Hepatology, 32, 289, 10.1053/jhep.2000.8895 · DOI
- Wojcicki, 2008, Biliary tract complications after liver transplantation: A review, Dig Surg, 25, 245, 10.1159/000144653 · DOI
- Geuken, 2004, Rapid increase of bile salt secretion is associated with bile duct injury after human liver transplantation, J Hepatol, 41, 1017, 10.1016/j.jhep.2004.08.023 · DOI
- Buis, 2009, Altered bile composition after liver transplantation is associated with the development of nonanastomotic biliary strictures, J Hepatol, 50, 69, 10.1016/j.jhep.2008.07.032 · DOI
- Hertl, 1995, Evidence of preservation injury to bile ducts by bile salts in the pig and its prevention by infusions of hydrophilic bile salts, Hepatology, 21, 1130, 10.1002/hep.1840210436 · DOI
- Imber, 2002, Optimisation of bile production during normothermic preservation of porcine livers, Am J Transplant, 2, 593, 10.1034/j.1600-6143.2002.20703.x · DOI
- Vairetti, 2008, Correlation between the liver temperature employed during machine perfusion and reperfusion damage: Role of Ca2+, Liver Transpl, 14, 494, 10.1002/lt.21421 · DOI
- Hoekstra, 2006, Bile salt toxicity aggravates cold ischemic injury of bile ducts after liver transplantation in mdr2+/− mice, Hepatology, 43, 1022, 10.1002/hep.21169 · DOI
- Hohenester, 2012, A biliary HCO3− umbrella constitutes a protective mechanism against bile acid-induced injury in human cholangiocytes, Hepatology, 55, 173, 10.1002/hep.24691 · DOI · Paper page
- Brockmann, 2009, Normothermic perfusion: A new paradigm for organ preservation, Ann Surg, 250, 1, 10.1097/SLA.0b013e3181a63c10 · DOI
- Tolboom, 2011, Subnormothermic machine perfusion at both 20°C and 30°C recovers ischemic rat livers for successful transplantation, J Surg Res, 175, 149, 10.1016/j.jss.2011.03.003 · DOI
Cited by
Sorted by citations
Han, Z., Rao, J. S., Gangwar, L., Namsrai, B.-E., Pasek-Allen, J. L., Etheridge, M. L., Wolf, S. M., Pruett, T. L., Bischof, J. C., & Finger, E. B. (2023) · Nature Communications · doi:10.1038/s41467-023-38824-8 · Cited by 173
Metadata
- Authors
- Bruinsma, B. G., Yeh, H., Özer, S., Martins, P. N., Farmer, A., Wu, W., Saeidi, N., Op den Dries, S., Berendsen, T. A., Smith, R. N., Markmann, J. F., Porte, R. J., Yarmush, M. L., Uygun, K., & Izamis, M.-L.
- Venue
- American Journal of Transplantation
- Publisher
- Elsevier BV
- Published
- 2014-06
- Volume
- 14
- Issue
- 6
- Pages
- 1400-1409
- ISSN
- 1600-6135
- PMC
- PMC4470578
- Cited by
- 187
- References
- 1
- Language
- en
- Licence
- Funders
- National Institutes of Health (R00DK080942, R01DK096075, R01EB008678)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review