Cited by 187

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Subnormothermic Machine Perfusion for Ex Vivo Preservation and Recovery of the Human Liver for Transplantation

Bruinsma, B.G., Yeh, H., Özer, S., Martins, P.N., Farmer, A., Wu, W., Saeidi, N., Op den Dries, S., Berendsen, T.A., Smith, R.N., Markmann, J.F., Porte, R.J., Yarmush, M.L., Uygun, K., Izamis, M.-L.·2014·American Journal of Transplantation

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/ajt.12727

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • These other technologies extend preservation for broader organ sharing but only increase preservation by hours to a few days and do not achieve prolonged banking for months and potentially years.

    “While these extend preservation for broader organ sharing, they only increase preservation by hours to a few days and do not achieve prolonged banking for months and potentially years.”
  • A range of other technologies are in use or being studied to prolong preservation times for kidneys and other organs, including hypothermic machine perfusion, normothermic machine perfusion, subnormothermic machine perfusion, high subzero supercooling, and partial freezing.

    “Further, a range of other technologies are in use or are being studied to prolong preservation times for kidneys and other organs, including hypothermic machine perfusion37, normothermic machine perfusion25, subnormothermic machine perfusion38, high subzero supercooling39,40, and partial freezing41.”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Flagged first, then by citations

Research works printed but not linked: 49

  1. Jain, 2000, Long-term survival after liver transplantation in 4,000 consecutive patients at a single center, Ann Surg, 232, 490, 10.1097/00000658-200010000-00004 · DOI
  2. McCormack, 2007, Use of severely steatotic grafts in liver transplantation: A matched case–control study, Ann Surg, 246, 940, 10.1097/SLA.0b013e31815c2a3f · DOI
  3. Moore, 2005, Impact of donor, technical, and recipient risk factors on survival and quality of life after liver transplantation, Arch Surg, 140, 273, 10.1001/archsurg.140.3.273 · DOI
  4. de Vera, 2009, Liver transplantation using donation after cardiac death donors: Long-term follow-up from a single center, Am J Transplant, 9, 773, 10.1111/j.1600-6143.2009.02560.x · DOI
  5. de Rougemont, 2009, One hour hypothermic oxygenated perfusion (HOPE) protects nonviable liver allografts donated after cardiac death, Ann Surg, 250, 674, 10.1097/SLA.0b013e3181bcb1ee · DOI
  6. Bessems, 2005, Improved machine perfusion preservation of the non-heart-beating donor rat liver using polysol: A new machine perfusion preservation solution, Liver Transpl, 11, 1379, 10.1002/lt.20502 · DOI
  7. Monbaliu, 2012, Preserving morphology and evaluating quality of liver grafts by hypothermic machine perfusion, a proof of concept study using discarded human livers, Liver Transpl, 18, 1495, 10.1002/lt.23550 · DOI
  8. Schlegel, 2013, Hypothermic oxygenated perfusion (HOPE) protects from biliary injury in a rodent model of DCD liver transplantation, J Hepatol, 59, 984, 10.1016/j.jhep.2013.06.022 · DOI
  9. Guarrera, 2010, Hypothermic machine preservation in human liver transplantation: The first clinical series, Am J Transplant, 10, 372, 10.1111/j.1600-6143.2009.02932.x · DOI
  10. Dutkowski, 2014, HOPE for human liver grafts obtained from donors after cardiac death, J Hepatol, 60, 765, 10.1016/j.jhep.2013.11.023 · DOI
  11. Xu, 2011, Excorporeal normothermic machine perfusion resuscitates pig DCD livers with extended warm ischemia, J Surg Res, 43, 1484
  12. Perk, 2011, A metabolic index of ischemic injury for perfusion-recovery of cadaveric rat livers, PLoS ONE, 6, e28518, 10.1371/journal.pone.0028518 · DOI
  13. Perk, 2012, A fitness index for transplantation of machine-perfused cadaveric rat livers, BMC Res Notes, 5, 325, 10.1186/1756-0500-5-325 · DOI
  14. Op den Dries, 2013, Ex vivo normothermic machine perfusion and viability testing of discarded human donor livers, Am J Transplant, 13, 1327, 10.1111/ajt.12187 · DOI
  15. Minor, 2013, Controlled oxygenated rewarming of cold stored liver grafts by thermally graduated machine perfusion prior to reperfusion, Am J Transplant, 13, 1450, 10.1111/ajt.12235 · DOI
  16. Shigeta, 2013, Impact of rewarming preservation by continuous machine perfusion: Improved post-transplant recovery in pigs, Transplant Proc, 45, 1684, 10.1016/j.transproceed.2013.01.098 · DOI
  17. Vajdová, 2002, ATP-supplies in the cold-preserved liver: A long-neglected factor of organ viability, Hepatology, 36, 1543, 10.1002/hep.1840360633 · DOI
  18. Berendsen, 2012, A simplified subnormothermic machine perfusion system restores ischemically damaged liver grafts in a rat model of orthotopic liver transplantation, Transplant Res, 1, 6, 10.1186/2047-1440-1-6 · DOI
  19. Tolboom, 2007, A model for normothermic preservation of the rat liver, Tissue Eng, 13, 2143, 10.1089/ten.2007.0101 · DOI
  20. Lüer, 2010, Role of oxygen during hypothermic machine perfusion preservation of the liver, Transpl Int, 23, 944
  21. Mitchell, 1999, Energy metabolism following prolonged hepatic cold preservation: Benefits of interrupted hypoxia on the adenine nucleotide pool in rat liver, Cryobiology, 39, 130, 10.1006/cryo.1999.2191 · DOI
  22. McCord, 1985, Oxygen-derived free radicals in postischemic tissue injury, N Engl J Med, 312, 159, 10.1056/NEJM198501173120305 · DOI · Paper page
  23. Reddy, 2004, Preservation of porcine non-heart-beating donor livers by sequential cold storage and warm perfusion, Transplantation, 77, 1328, 10.1097/01.TP.0000119206.63326.56 · DOI
  24. Ferrigno, 2011, Machine perfusion at 20°C reduces preservation damage to livers from non-heart beating donors, Cryobiology, 62, 152, 10.1016/j.cryobiol.2011.02.004 · DOI
  25. Lanir, 1988, Hepatic transplantation survival: Correlation with adenine nucleotide level in donor liver, Hepatology, 8, 471, 10.1002/hep.1840080306 · DOI
  26. Kamiike, 1988, Adenine nucleotide metabolism and its relation to organ viability in human liver transplantation, Transplantation, 45, 138, 10.1097/00007890-198801000-00030 · DOI
  27. Usta, 2013, Supercooling as a viable non-freezing cell preservation method of rat hepatocytes, PLoS ONE, 8, e69334, 10.1371/journal.pone.0069334 · DOI
  28. Berendsen, 2011, Hepatocyte viability and adenosine triphosphate content decrease linearly over time during conventional cold storage of rat liver grafts, Transplant Proc, 43, 1484, 10.1016/j.transproceed.2010.12.066 · DOI
  29. Bruinsma, 2013, Determination and extension of the limits to static cold storage using subnormothermic machine perfusion, Int J Artif Organs, 36, 775, 10.5301/ijao.5000250 · DOI
  30. Minor, 2003, Fibrinolysis in organ procurement for transplantation after cardiocirculatory compromise, Thromb Haemost, 90, 361, 10.1055/s-0037-1613489 · DOI
  31. Koetting, 2011, Donation after cardiac death: Dynamic graft reconditioning during or after ischemic preservation?, Artif Organs, 35, 565, 10.1111/j.1525-1594.2010.01138.x · DOI
  32. St Peter, 2002, Extended preservation of non-heart-beating donor livers with normothermic machine perfusion, Br J Surg, 89, 609, 10.1046/j.1365-2168.2002.02052.x · DOI
  33. Butler, 2002, Successful extracorporeal porcine liver perfusion for 72 hr, Transplantation, 73, 1212, 10.1097/00007890-200204270-00005 · DOI
  34. Bessems, 2006, Machine perfusion preservation of the pig liver using a new preservation solution, polysol, Transplant Proc, 38, 1238, 10.1016/j.transproceed.2006.02.063 · DOI
  35. Reddy, 2005, Non-heart-beating donor porcine livers: The adverse effect of cooling, Liver Transpl, 11, 35, 10.1002/lt.20287 · DOI
  36. van der Plaats, 2006, The Groningen hypothermic liver perfusion pump: Functional evaluation of a new machine perfusion system, Ann Biomed Eng, 34, 1924, 10.1007/s10439-006-9207-4 · DOI
  37. Miyagi, 2008, The significance of preserving the energy status and microcirculation in liver grafts from non-heart-beating donor, Cell Transplant, 17, 173, 10.3727/000000008783906874 · DOI
  38. Friend, 2001, Normothermic perfusion of the isolated liver, Transplant Proc, 33, 3436, 10.1016/S0041-1345(01)02481-2 · DOI
  39. Vajdová, 2000, Cold-preservation-induced sensitivity of rat hepatocyte function to rewarming injury and its prevention by short-term reperfusion, Hepatology, 32, 289, 10.1053/jhep.2000.8895 · DOI
  40. Wojcicki, 2008, Biliary tract complications after liver transplantation: A review, Dig Surg, 25, 245, 10.1159/000144653 · DOI
  41. Geuken, 2004, Rapid increase of bile salt secretion is associated with bile duct injury after human liver transplantation, J Hepatol, 41, 1017, 10.1016/j.jhep.2004.08.023 · DOI
  42. Buis, 2009, Altered bile composition after liver transplantation is associated with the development of nonanastomotic biliary strictures, J Hepatol, 50, 69, 10.1016/j.jhep.2008.07.032 · DOI
  43. Hertl, 1995, Evidence of preservation injury to bile ducts by bile salts in the pig and its prevention by infusions of hydrophilic bile salts, Hepatology, 21, 1130, 10.1002/hep.1840210436 · DOI
  44. Imber, 2002, Optimisation of bile production during normothermic preservation of porcine livers, Am J Transplant, 2, 593, 10.1034/j.1600-6143.2002.20703.x · DOI
  45. Vairetti, 2008, Correlation between the liver temperature employed during machine perfusion and reperfusion damage: Role of Ca2+, Liver Transpl, 14, 494, 10.1002/lt.21421 · DOI
  46. Hoekstra, 2006, Bile salt toxicity aggravates cold ischemic injury of bile ducts after liver transplantation in mdr2+/− mice, Hepatology, 43, 1022, 10.1002/hep.21169 · DOI
  47. Hohenester, 2012, A biliary HCO3− umbrella constitutes a protective mechanism against bile acid-induced injury in human cholangiocytes, Hepatology, 55, 173, 10.1002/hep.24691 · DOI · Paper page
  48. Brockmann, 2009, Normothermic perfusion: A new paradigm for organ preservation, Ann Surg, 250, 1, 10.1097/SLA.0b013e3181a63c10 · DOI
  49. Tolboom, 2011, Subnormothermic machine perfusion at both 20°C and 30°C recovers ischemic rat livers for successful transplantation, J Surg Res, 175, 149, 10.1016/j.jss.2011.03.003 · DOI

Cited by

Sorted by citations

Metadata

Authors
Bruinsma, B. G., Yeh, H., Özer, S., Martins, P. N., Farmer, A., Wu, W., Saeidi, N., Op den Dries, S., Berendsen, T. A., Smith, R. N., Markmann, J. F., Porte, R. J., Yarmush, M. L., Uygun, K., & Izamis, M.-L.
Venue
American Journal of Transplantation
Publisher
Elsevier BV
Published
2014-06
Volume
14
Issue
6
Pages
1400-1409
ISSN
1600-6135
Cited by
187
References
1
Language
en
Funders
National Institutes of Health (R00DK080942, R01DK096075, R01EB008678)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review