Cuffed vs. uncuffed tracheal tubes in children: a randomised controlled trial comparing leak, tidal volume and complications
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Summary: Cuffed tracheal tubes are increasingly used in paediatric anaesthetic practice. This study compared tidal volume and leakage around cuffed and uncuffed tracheal tubes in children who required standardised mechanical ventilation of their lungs in the operating theatre. Children (0–16 years) undergoing elective surgery requiring tracheal intubation were randomly assigned to receive either a cuffed or an uncuffed tracheal tube. Assessments were made at five different time‐points: during volume‐controlled ventilation 6 ml.kg −1 , PEEP 5 cmH 2 O and during pressure‐controlled ventilation 10 cmH 2 O / PEEP 5 cmH 2 O. The pressure‐controlled ventilation measurement time‐points were: just before a standardised recruitment manoeuvre; just after recruitment manoeuvre; 10 min; and 30 min after the recruitment manoeuvre. Problems and complications were recorded. During volume‐controlled ventilation, leakage was significantly less with cuffed tracheal tubes than with uncuffed tracheal tubes; in ml.kg −1 , median (IQR [range]) 0.20 (0.13–0.39 [0.04–0.60]) vs. 0.82 (0.58–1.38 [0.24–4.85]), respectively, p < 0.001. With pressure‐controlled ventilation, leakage was less with cuffed tracheal tubes and stayed unchanged over a 30‐min period, whereas with uncuffed tracheal tubes, leakage was higher and increased further over the 30‐min period. Tidal volumes were higher in the cuffed group and increased over time, but in the uncuffed group were lower and decreased over time. Both groups showed an increase in tidal volumes following recruitment manoeuvres. There were more short‐term complications with uncuffed tracheal tubes, but no major complications were recorded in either group at long‐term follow‐up. With standardised ventilator settings, cuffed tracheal tubes produced better ventilation characteristics compared with uncuffed tracheal tubes during general anaesthesia for routine elective surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Comparison of Cuffed and Uncuffed Endotracheal Tubes in Young Children during General Anesthesia
Khine, H. H., Corddry, D. H., Kettrick, R. G., Martin, T. M., McCloskey, J. J., Rose, J. B., Theroux, M. C., & Zagnoev, M. (1997) · Anesthesiology · doi:10.1097/00000542-199703000-00015 · Cited by 480 · cited 1×
“Others were randomised studies that looked at children as a single group in an anaesthetic setting rather than dividing them into specific age groups [4].”
BackgroundWeiss, M., Dullenkopf, A., Fischer, J. E., Keller, C., & Gerber, A. C. (2009) · British Journal of Anaesthesia · doi:10.1093/bja/aep290 · Cited by 364 · cited 3×
“[1] included sub-group analysis of small infants in an anaesthetic setting, and demonstrated that cuffed TT did not have worse outcomes than uncuffed, and were associated with fewer insertion attempts.”
BackgroundResultCuffed endotracheal tubes in pediatric intensive care
Deakers, T. W., Reynolds, G., Stretton, M., & Newth, C. J. L. (1994) · The Journal of Pediatrics · doi:10.1016/s0022-3476(94)70121-0 · Cited by 239 · cited 1×
“Some of these studies were performed in an intensive care setting where intubation and ventilation were carried out for prolonged periods [3], but were of an observational nature.”
BackgroundGopalareddy, V. V., He, Z., Soundar, S., Bolling, L., Shah, M., Penfil, S., McCloskey, J. J., & Mehta, D. I. (2007) · Acta Paediatrica · doi:10.1111/j.1651-2227.2007.00578.x · Cited by 75 · cited 1×
“Advantages of the use of cuffed TT are reported as being a reduced need for multiple intubation attempts to correctly size a tube [1]; lower atmospheric pollution [6, 8] due to lack of a leak; more reliable capnography [1]; lower risk of micro-aspiration [9]; decreased sore throat [2]; lower risk of airway fires durin…”
BackgroundRole of Airway Recruitment and Derecruitment in Lung Injury
Ghadiali, S. N., & Huang, Y. (2011) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v39.i4.40 · Cited by 42 · cited 1×
“It is suggested that a cyclical process of recruitment and atelectasis may contribute to lung inflammation [15].”
Background
Cited by
Topjian, A. A., Raymond, T. T., Atkins, D., Chan, M., Duff, J. P., Joyner, B. L., Lasa, J. J., Lavonas, E. J., Levy, A., Mahgoub, M., et al. (2020) · Circulation · doi:10.1161/cir.0000000000000901 · Cited by 1,258
Merchant, R. M., Topjian, A. A., Panchal, A. R., Cheng, A., Aziz, K., Berg, K. M., Lavonas, E. J., Magid, D. J., & On behalf of the Adult Basic and Advanced Life Support, P. B. A. A. L. S. (2020) · Circulation · doi:10.1161/cir.0000000000000918 · Cited by 1,126
Anesthesia for major surgery in the neonate
Kuan, C. C., & Shaw, S. J. (2020) · Anesthesiology Clinics · doi:10.1016/j.anclin.2019.10.001 · Cited by 26
Metadata
- Authors
- Chambers, N. A., Ramgolam, A., Sommerfield, D., Zhang, G., Ledowski, T., Thurm, M., Lethbridge, M., Hegarty, M., & von Ungern‐Sternberg, B. S.
- Venue
- Anaesthesia
- Publisher
- Wiley
- Published
- 2017-11-23
- Volume
- 73
- Issue
- 2
- Pages
- 160-168
- ISSN
- 0003-2409 (ISSN-L)
- 1365-2044
- OpenAlex
- W2769002019
- Cited by
- 171
- References
- 5
- FWCI
- 42.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.