The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Bedside tests for predicting difficult airways: an abridged Cochrane diagnostic test accuracy systematic review
Abstract
Summary: Although bedside screening tests are routinely used to identify people at high risk of having a difficult airway, their clinical utility is unclear. We estimated the diagnostic accuracy of commonly used bedside examination tests for assessing the airway in adult patients without apparent anatomical abnormalities scheduled to undergo general anaesthesia. We searched for studies that reported our pre‐specified bedside index screening tests against a reference standard, published in any language, from date of inception to 16 December 2016, in seven bibliographic databases. We included 133 studies (127 cohort type and 6 case–control) involving 844,206 participants. Overall, their methodological quality (according to QUADAS ‐2, a standard tool for assessing quality of diagnostic accuracy studies) was moderate to high. Our pre‐specified tests were: the Mallampati test (6 studies); modified Mallampati test (105 studies); Wilson risk score (6 studies); thyromental distance (52 studies); sternomental distance (18 studies); mouth opening test (34 studies); and the upper lip bite test (30 studies). Difficult facemask ventilation, difficult laryngoscopy, difficult intubation and failed intubation were the reference standards in seven, 92, 50 and two studies, respectively. Across all reference standards, we found all index tests had relatively low sensitivities, with high variability, but specificities were consistently and markedly higher than sensitivities. For difficult laryngoscopy, the sensitivity and specificity (95% CI ) of the upper lip bite test were 0.67 (0.45–0.83) and 0.92 (0.86–0.95), respectively; upper lip bite test sensitivity (95% CI ) was significantly higher than that for the mouth opening test (0.22, 0.13–0.33; p < 0.001). For difficult tracheal intubation, the modified Mallampati test had a significantly higher sensitivity (95% CI ) at 0.51 (0.40–0.61) compared with mouth opening (0.27, 0.16–0.41; p < 0.001) and thyromental distance (0.24, 0.12–0.43; p < 0.001). Although the upper lip bite test showed the most favourable diagnostic test accuracy properties, none of the common bedside screening tests is well suited for detecting unanticipated difficult airways, as many of them are missed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Cited by
Roth, D., Pace, N. L., Lee, A., Hovhannisyan, K., Warenits, A.-M., Arrich, J., & Herkner, H. (2018) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008874.pub2 · Cited by 257
Self-citation
Metadata
- Authors
- Roth, D., Pace, N. L., Lee, A., Hovhannisyan, K., Warenits, A. M., Arrich, J., & Herkner, H.
- Venue
- Anaesthesia
- Publisher
- Wiley
- Published
- 2019-03-06
- Volume
- 74
- Issue
- 7
- Pages
- 915-928
- ISSN
- 0003-2409 (ISSN-L)
- 1365-2044
- OpenAlex
- W2920910357
- Cited by
- 160
- References
- 1
- FWCI
- 6.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bedside tests for predicting difficult airways: an abridged Cochrane diagnostic test accuracy systematic review. https://app.cochat.ai/papers/10.1111/anae.14608
- The paper
- Roth, D., Pace, N. L., Lee, A., Hovhannisyan, K., Warenits, A. M., Arrich, J., & Herkner, H. (2019). Bedside tests for predicting difficult airways: an abridged Cochrane diagnostic test accuracy systematic review. Anaesthesia. https://doi.org/10.1111/anae.14608
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.