CoChat

The aerosol box for intubation in coronavirus disease 2019 patients: an in‐situ simulation crossover study

Open access
Begley, J. L., Lavery, K. E., Nickson, C. P., Brewster, D. J. · 2020 · Anaesthesia
Cited by 232

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

The coronavirus disease 2019 pandemic has led to the manufacturing of novel devices to protect clinicians from the risk of transmission, including the aerosol box for use during tracheal intubation. We evaluated the impact of two aerosol boxes (an early‐generation box and a latest‐generation box) on intubations in patients with severe coronavirus disease 2019 with an in‐situ simulation crossover study. The simulated process complied with the Safe Airway Society coronavirus disease 2019 airway management guidelines. The primary outcome was intubation time; secondary outcomes included first‐pass success and breaches to personal protective equipment. All intubations were performed by specialist (consultant) anaesthetists and video recorded. Twelve anaesthetists performed 36 intubations. Intubation time with no aerosol box was significantly shorter than with the early‐generation box (median (IQR [range]) 42.9 (32.9–46.9 [30.9–57.6])s vs. 82.1 (45.1–98.3 [30.8–180.0])s p = 0.002) and the latest‐generation box (52.4 (43.1–70.3 [35.7–169.2])s, p = 0.008). No intubations without a box took more than 1 min, whereas 14 (58%) intubations with a box took over 1 min and 4 (17%) took over 2 min (including one failure). Without an aerosol box, all anaesthetists obtained first‐pass success. With the early‐generation and latest‐generation boxes, 9 (75%) and 10 (83%) participants obtained first‐pass success, respectively. One breach of personal protective equipment occurred using the early‐generation box and seven breaches occurred using the latest‐generation box. Aerosol boxes may increase intubation times and therefore expose patients to the risk of hypoxia. They may cause damage to conventional personal protective equipment and therefore place clinicians at risk of infection. Further research is required before these devices can be considered safe for clinical use.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/anae.15115

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Metadata

Authors
Begley, J. L., Lavery, K. E., Nickson, C. P., & Brewster, D. J.
Venue
Anaesthesia
Publisher
Wiley
Published
2020-06
Volume
75
Issue
8
Pages
1014-1021
ISSN
  • 0003-2409 (ISSN-L)
  • 1365-2044
OpenAlex
W3025934939
Cited by
232
References
17
FWCI
59.48
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.