Diagnostic accuracy of ultrasound and MRI in the prenatal diagnosis of placenta accreta
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Objective: To analyze the value of ultrasound followed by magnetic resonance imaging (MRI) in doubtful cases for antenatal detection of placenta accreta. Design: A prospective observational study. Setting: Hospital in the southern region, Saudi Arabia. Sample: Patients with a low‐lying placenta or placenta previa. Methods: The placentas of all included cases were scanned in a systematic fashion using both gray‐scale and color Doppler (transabdominal and transvaginal). Main outcome measures: Explicit ultrasound criteria for placenta accreta were carefully applied, and any case with two or more criteria was labeled as highly suspicious. If only one criterion was detected, then the case was labeled as suspicious and MRI was applied. Results: Five hundred and seventy seven women had a diagnosis of low‐lying placenta or placenta previa. Of these, 42 had placenta accreta confirmed after delivery by pathological examination, and 39 of these were diagnosed prenatally. Ultrasound accurately predicted placenta accreta in 33 of 39 of women and correctly ruled out placenta accreta in 512 of 514 without placenta accreta (sensitivity 95.1% and specificity 95.5%). Twenty (20) women underwent MRI because of suspicion of placenta accreta by ultrasonography. MRI accurately predicted placenta accreta in six of 20 cases and correctly ruled out placenta accreta in 10 of 20 cases (sensitivity 85.7% and specificity 76.9%). Conclusion: Placenta accreta can be successfully detected prenatally using ultrasound. MRI can provide additional information in doubtful cases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Abnormal placentation: Twenty-year analysis
Wu, S., Kocherginsky, M., & Hibbard, J. U. (2005) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2004.12.074 · Cited by 1,331 · cited 2×
“The incidence varies from 1 in 533 to 1 in 2510 deliveries (2,3).”
BackgroundThe management of placenta percreta: Conservative and operative strategies
O'Brien, J. M., Barton, J. R., & Donaldson, E. S. (1996) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(96)70117-5 · Cited by 625 · cited 1×
“While some have advised that elective delivery should be scheduled earlier in gestation (34 weeks) to prevent unexpected bleeding before term (16), others (17) have recommend postponing the procedure until 36 weeks, when the liability for neonatal respiratory distress is reduced.”
BackgroundPlacenta Accreta: Spectrum of US and MR Imaging Findings
Baughman, W. C., Corteville, J. E., & Shah, R. R. (2008) · RadioGraphics · doi:10.1148/rg.287085060 · Cited by 341 · cited 1×
“They are thought to represent areas of fibrin deposition within the placenta (8,9) (Figure 2).”
BackgroundPrenatal diagnosis of placenta previa accreta by transabdominal color Doppler ultrasound
Chou, M. M., Ho, E. S. C., & Lee, Y. H. (2000) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.2000.00018.x · Cited by 284
Effectiveness of Timing Strategies for Delivery of Individuals With Placenta Previa and Accreta
Robinson, B. K., & Grobman, W. A. (2010) · Obstetrics & Gynecology · doi:10.1097/aog.0b013e3181f3588d · Cited by 276 · cited 1×
“While some have advised that elective delivery should be scheduled earlier in gestation (34 weeks) to prevent unexpected bleeding before term (16), others (17) have recommend postponing the procedure until 36 weeks, when the liability for neonatal respiratory distress is reduced.”
Background
Cited by
FIGO consensus guidelines on placenta accreta spectrum disorders: Epidemiology,
Jauniaux, E., Chantraine, F., Silver, R. M., Langhoff‐Roos, J., & Panel, F. T. F. P. A. D. A. M. E. C. (2018) · International Journal of Gynecology & Obstetrics · doi:10.1002/ijgo.12407 · Cited by 498
Jauniaux, E., & Bhide, A. (2017) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2017.02.050 · Cited by 348
“Five studies included both low-lying and placenta previa in their screening population of women with a previous cesarean delivery.(25,26,29,32,38) In only one of these studies,(29) the low-lying placenta was described as a placental edge within 2 cm of the cervical os but not covering it.”
BackgroundD'Antonio, F., Iacovella, C., Palacios-Jaraquemada, J., Bruno, C. H., Manzoli, L., & Bhide, A. (2014) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.13327 · Cited by 324
Jauniaux, E., Collins, S. L., Jurkovic, D., & Burton, G. J. (2016) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2016.07.044 · Cited by 208
Vahanian, S. A., Lavery, J. A., Ananth, C. V., & Vintzileos, A. (2015) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2015.05.058 · Cited by 180
“These were individually reviewed and from these, information regarding PIA and their association with preterm delivery was available in only 79 studies.(2,8,12-89) These studies were critically reviewed and data were extracted by 1 author.”
Method
Metadata
- Authors
- Maher, M. A., Abdelaziz, A., & Bazeed, M. F.
- Venue
- Acta Obstetricia et Gynecologica Scandinavica
- Publisher
- Wiley
- Published
- 2013-06-28
- Volume
- 92
- Issue
- 9
- Pages
- 1017-1022
- ISSN
- 0001-6349 (ISSN-L)
- 1600-0412
- OpenAlex
- W2043548840
- Cited by
- 61
- References
- 5
- FWCI
- 3.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnostic accuracy of ultrasound and MRI in the prenatal diagnosis of placenta accreta. https://app.cochat.ai/papers/10.1111/aogs.12187
- The paper
- Maher, M. A., Abdelaziz, A., & Bazeed, M. F. (2013). Diagnostic accuracy of ultrasound and MRI in the prenatal diagnosis of placenta accreta. Acta Obstetricia et Gynecologica Scandinavica. https://doi.org/10.1111/aogs.12187
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.