Diagnostic accuracy of ultrasound in detecting the severity of abnormally invasive placentation: a systematic review and meta‐analysis
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Introduction: Our objective was to elucidate the overall diagnostic accuracy of ultrasound in detecting the severity of abnormally invasive placentation (AIP). Material and methods: Medline, Embase, CINAHL and The Cochrane databases were searched. The ultrasound signs explored were: loss of hypoechoic (clear) zone in the placental–uterine interface, placental lacunae, bladder wall interruption, myometrial thinning, focal exophitic mass, placental lacunar flow, subplacental vascularity, and uterovesical hypervascularity. Results: Twenty studies (3209 pregnancies) were included. Ultrasound had an overall good diagnostic accuracy in identifying the depth of placental invasion with sensitivities of 90.6%, 93.0%, 89.5%, and 81.2% for placenta accreta, increta, accreta/increta, and percreta, respectively; the corresponding specificities were 97.1%, 98.4%, 94.7%, and 98.9%. Placental lacunae had sensitivities of 74.8%, 88.6%, and 76.3% for the detection of placenta accreta, increta, and percreta, respectively. Sensitivity and specificity of loss of the clear zone in identifying placenta accreta were 74.9% and 92.0%, whereas the corresponding figures for placenta increta and percreta were 91.6% and 76.9%, and 88.1% and 71.1%. Lacunar flow had sensitivities of 81.2%, 84.3%, and 45.2% for the detection of placenta accreta, increta, and percreta respectively; the corresponding figures for specificity were 84.0%, 79.7%, and 75.3%. Sensitivity of uterovesical hypervascularity was low for the detection of placenta accreta (12.3%) but high for placenta increta (94.4%) and percreta (86.2%); the corresponding figures for specificity were 90.8%, 88.0% and 88.2%, respectively. Conclusions: Ultrasound has an overall good diagnostic accuracy in recognizing the depth and the topography of placental invasion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
The diagnostic odds ratio: a single indicator of test performance
Glas, A. S., Lijmer, J. G., Prins, M. H., Bonsel, G. J., & Bossuyt, P. M. M. (2003) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(03)00177-x · Cited by 2,261
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Hunter, J. P., Saratzis, A., Sutton, A. J., Boucher, R. H., Sayers, R. D., & Bown, M. J. (2014) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2014.03.003 · Cited by 786
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W., Westwood, M. E., Mallett, S. V., Deeks, J. J., Reitsma, J. B., Leeflang, M., Sterne, J. A. C., & Bossuyt, P. M. (2011) · Data Archiving and Networked Services (DANS) · doi:10.1059/0003-4819-155-8-201110180-00009 · Cited by 601
Belfort, M. A. (2010) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2010.09.013 · Cited by 484
metandi: Meta-analysis of diagnostic accuracy using hierarchical logistic regression
Harbord, R. M., & Whiting, P. (2009) · The Stata Journal: Promoting communications on statistics and Stata · doi:10.1177/1536867x0900900203 · Cited by 453
D'Antonio, F., Iacovella, C., & Bhide, A. (2013) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.13194 · Cited by 398 · cited 1×
“We have previously shown that ultrasound has an overall good diagnostic accuracy in detecting AIP (7).”
BackgroundSelf-citationProposal for standardized ultrasound descriptors of abnormally invasive placenta ( AIP )
Collins, S. L., Ashcroft, A., Braun, T., Calda, P., Langhoff‐Roos, J., Morel, O., Stefanovic, V., Tutschek, B., Chantraine, F., & on behalf of the European Working Group on Abnormally Invasive Placenta (EW‐AIP) (2016) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.14952 · Cited by 331
Cited by
Tinari, S., Buca, D., Cali, G., Timor‐Tritsch, I., Palacios‐Jaraquemada, J., Rizzo, G., Lucidi, A., Di Mascio, D., Liberati, M., & D'Antonio, F. (2021) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.22183 · Cited by 89
Self-citationUp-regulated cytotrophoblast DOCK4 contributes to over-invasion in placenta accreta spectrum
McNally, L., Zhou, Y., Robinson, J. F., Zhao, G., Chen, L.-M., Chen, H., Kim, M. Y., Kapidzic, M., Gormley, M., Hannibal, R., et al. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1920776117 · Cited by 41
Comparing three‐dimensional models of placenta accreta spectrum with surgical findings
Mulligan, K. M., Bartels, H. C., Armstrong, F., Immel, E., Corcoran, S., Walsh, J. M., McAuliffe, F., McParland, P., Carroll, S., Higgins, S., et al. (2022) · International Journal of Gynecology & Obstetrics · doi:10.1002/ijgo.13743 · Cited by 17
Metadata
- Authors
- Pagani, G., Cali, G., Acharya, G., Trisch, I., Palacios‐Jaraquemada, J., Familiari, A., Buca, D., Manzoli, L., Flacco, M. E., Fanfani, F., Liberati, M., Scambia, G., & D'antonio, F.
- Venue
- Acta Obstetricia et Gynecologica Scandinavica
- Publisher
- Wiley
- Published
- 2017-11-28
- Volume
- 97
- Issue
- 1
- Pages
- 25-37
- ISSN
- 0001-6349 (ISSN-L)
- 1600-0412
- OpenAlex
- W2757563419
- Cited by
- 144
- References
- 14
- FWCI
- 2.58
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnostic accuracy of ultrasound in detecting the severity of abnormally invasive placentation: a systematic review and meta‐analysis. https://app.cochat.ai/papers/10.1111/aogs.13238
- The paper
- Pagani, G., Cali, G., Acharya, G., Trisch, I., Palacios‐Jaraquemada, J., Familiari, A., Buca, D., Manzoli, L., Flacco, M. E., Fanfani, F., Liberati, M., Scambia, G., & D'antonio, F. (2018). Diagnostic accuracy of ultrasound in detecting the severity of abnormally invasive placentation: a systematic review and meta‐analysis. Acta Obstetricia et Gynecologica Scandinavica. https://doi.org/10.1111/aogs.13238
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.