Arterio-venous blood gas Δvalues for validation of umbilical cord blood samples at birth are not only biased by sample mix ups but also affected by clinical factors
Open accessAbstract
Abstract Introduction Traditional validation of umbilical cord blood samples with positive veno‐arterial ΔpH and arterio‐venous ΔpCO2 values confirms the source of samples, whereas negative Δvalues represent mix‐up of samples. To investigate whether this is true, the distributions of V‐A ΔpO2 and A‐V Δlactate were also explored and related to clinical characteristics. In addition, different cord blood sampling techniques were evaluated. Material and methods Register study with cord blood acid‐base and clinical data from 27 233 newborns. Clinical characteristics were related to positive, zero and negative Δvalues. Blood samplings from unclamped and double‐clamped cords were compared. A two‐sided P < 0.05 was considered significant. Results ΔpH and ΔpCO2 values distributed into positive, around zero, and negative sub‐populations, with significant differences in pH and clinical characteristics between sub‐populations. No such sub‐populations were distinguished for ΔpO2 and Δlactate. The 2.5th and 5th ΔpH percentiles were 0.013 and 0.022, respectively, and for ΔpCO2 0.30 and 0.53 kPa. Applying 5th percentile criteria resulted in 3.5% of “approved” cases showing a ΔpO2 ≤ 0. Puncture and sampling of the unclamped cord resulted in significantly better sample quality. Conclusions Unphysiological negative ΔpO2 values occurred despite correct validation with traditional criteria. Δlactate cannot be used for validation because both positive and negative values are physiological. Positive/around zero/negative ΔpH and ΔpCO2 sub‐populations were associated with significant differences in pH and clinical characteristics, indicating that defective sampling and sample handling are not the sole explanations for negative Δvalues. Prompt puncture and sampling of the unclamped cord resulted in best sample quality.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Arteriovenous Dlactate cannot be used at all because 35% of values are either negative or null.
“Arteriovenous Dlactate cannot be used at all because 35% of values are either negative or null.”
From Umbilical cord pH, blood gases, and lactate at birth: normal values, interpretation, and clinical utility. (2023) · cites this paper as [63]
The Results report that 35% of Δlactate values were negative or zero. They conclude that Δlactate cannot be used to validate umbilical cord blood samples because both positive and negative values can be physiological. The claim’s “cannot be used at all” is broader than that conclusion. (LLM, conf=0.86)
Experimental — accuracy not yet measuredIn a study of 27,233 deliveries with paired cord blood samples, the only undisputed validation tool is DpO2 because the fetus cannot produce O2.
“We found that the only undisputed validation tool is DpO 2 because the fetus cannot produce O 2 .”
From Umbilical cord pH, blood gases, and lactate at birth: normal values, interpretation, and clinical utility. (2023) · cites this paper as [63]
Double validation with both DpH and DpCO2 is not needed because the difference between DpH alone and DpH combined with DpCO2 is small; DpH validation alone is enough.
“We also concluded that double validation with both DpH and DpCO 2 is not needed because the difference between DpH alone and DpH combined with DpCO 2 is small; DpH validation alone is enough.”
From Umbilical cord pH, blood gases, and lactate at birth: normal values, interpretation, and clinical utility. (2023) · cites this paper as [63]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
SOOTHILL, P. W., Nicolaides, K. H., Rodeck, C. H., & Campbell, S. C. (1986) · Fetal Diagnosis and Therapy · doi:10.1159/000262264 · Cited by 265 · see citing works
Umbilical cord blood gas analysis at delivery: a time for quality data
Westgate, J., Garibaldi, J. M., & Greene, K. R. (1994) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1994.tb13581.x · Cited by 244 · see citing works
SOOTHILL, P. W., Nicolaides, K. H., Rodeck, C. H., & Campbell, S. C. (1988) · Obstetrical & Gynecological Survey · doi:10.1097/00006254-198843010-00005 · Cited by 227 · see citing works
Placental production and foetal utilisation of lactate and pyruvate
Burd, L. I., JONES, M. D., Simmons, M. A., Makowski, E. L., Meschia, G., & Battaglia, F. C. (1975) · Nature · doi:10.1038/254710a0 · Cited by 201 · see citing works
Wiberg, N., Källén, K., & Olofsson, P. (2008) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2008.01708.x · Cited by 121 · see citing works
Self-citationArterial or venous umbilical pH as a measure of neonatal morbidity?
Huisjes, H. J., & Aarnoudse, J. G. (1979) · Early Human Development · doi:10.1016/0378-3782(79)90004-5 · Cited by 62 · see citing works
Wiberg, N., Källén, K., Herbst, A., Åberg, A., & Olofsson, P. (2008) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2008.01707.x · Cited by 57 · see citing works
Self-citationBlood gases and acid-base status of the human second-trimester fetus.
SOOTHILL, P. W., Nicolaides, K. H., Rodeck, C. H., & Gamsu, H. R. (1986) · PubMed · Cited by 57 · see citing works
A new tool for the validation of umbilical cord acid–base data
Kro, G., Yli, B. M., Rasmussen, S., Norén, H., Amer‐Wåhlin, I., Saugstad, O. D., Stray‐Pedersen, B., & Rosén, K. G. (2010) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2010.02711.x · Cited by 52 · see citing works
Blood Gases and Acid-Base Status of the Human Second-Trimester Fetus
Soothill, P. W., Nicolaides, K. H., Rodeck, C., et al. (1987) · Obstetric Anesthesia Digest · doi:10.1097/00132582-198704000-00010 · Cited by 44 · see citing works
Lactate Movements in the Term Human Placenta in situ
Piquard, F., Schaefer, A., Dellenbach, P., et al. (2009) · Biology of the Neonate · doi:10.1159/000243233 · Cited by 32 · see citing works
White, C., Doherty, D., Kohan, R., Newnham, J., & Pennell, C. (2012) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2012.03308.x · Cited by 28 · see citing works
Cord blood sampling at delivery: do we need to always collect from both vessels?
Tong, S. Y. C., Egan, V., Griffin, J., et al. (2002) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2002.01072.x · Cited by 26 · see citing works
Blood gas values in clamped and unclamped umbilical cord at birth
Tommaso, M. D., Seravalli, V., Martini, I., et al. (2014) · Early Human Development · doi:10.1016/j.earlhumdev.2014.03.010 · Cited by 23 · see citing works
Mokarami, P., Wiberg, N., & Olofsson, P. (2013) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.12234 · Cited by 23 · see citing works
Self-citationWestgate, J. (1993) · OpenGrey (Institut de l'Information Scientifique et Technique) · doi:10.24382/4871 · Cited by 8 · see citing works
Olofsson, P., Mokarami, P., Källén, K., & Wiberg, N. (2011) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1111/j.1600-0412.2011.01241.x · Cited by 7 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Olofsson, P. (2023) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2022.07.001 · Cited by 104 · see citing works
Self-citationZaigham, M., Källén, K., & Olofsson, P. (2019) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1111/aogs.13689 · Cited by 31 · see citing works
Self-citation
- Authors
- Mokarami, P., Wiberg, N., Källén, K., & Olofsson, P.
- Affiliations
- Lund University (SE)
- Corresponding author
- Olofsson, Per
- Venue
- Acta Obstetricia Et Gynecologica Scandinavica
- Publisher
- Wiley
- Published
- 2018-10-30
- Volume
- 98
- Issue
- 2
- Pages
- 167-175
- ISSN
- 0001-6349 (ISSN-L)
- 1600-0412
- OpenAlex
- W2893735355
- Cited by
- 19
- References
- 17
- Citations by year
- 2026: 10 · 2025: 1 · 2024: 1 · 2023: 3 · 2022: 1 · 2021: 2 · 2019: 1
- FWCI
- 0.51
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Acta Obstetricia Et Gynecologica Scandinavica (publishedVersion)
- PubMed (publishedVersion)
- Lund University Publications (Lund University) (submittedVersion)
- Funders
- Region Skåne
- Lunds Universitet
- Topics
- Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Neonatal Health and Biochemistry
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Neonatal Respiratory Health Research
- Keywords
- umbilical cord blood, sample validation, arteriovenous oxygen difference, lactate, umbilical cord clamping, sample mix-up, neonatal acid-base status, clinical features
- MeSH terms
- Acid-Base Equilibrium, Adult, Blood Gas Analysis, Blood Specimen Collection, Carbon Dioxide, Female, Fetal Hypoxia, Fetal Blood, Humans, Hydrogen-Ion Concentration, Infant, Newborn, Oxygen, Pregnancy, Sweden, Reproducibility of Results, Delivery, Obstetric
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review