Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 181

The DOI matches its Crossref record.

Porous Titanium‐6 Aluminum‐4 Vanadium Cage Has Better Osseointegration and Less Micromotion Than a Poly‐Ether‐Ether‐Ketone Cage in Sheep Vertebral Fusion

Wu, Su‐Hua, Li, Yi, Zhang, Yong‐Quan, Li, Xiao‐Kang, Yuan, Chao‐Fan, Hao, Yu‐Lin, Zhang, Zhi‐Yong, Guo, Zheng·2013·Artificial Organs

Abstract

Interbody fusion cages made of poly‐ether‐ether‐ketone (PEEK) have been widely used in clinics for spinal disorders treatment; however, they do not integrate well with surrounding bone tissue. T i‐6 A l‐4 V (T i) has demonstrated greater osteoconductivity than PEEK, but the traditional T i cage is generally limited by its much greater elastic modulus (110 GPa) than natural bone (0.05–30 GPa). In this study, we developed a porous T i cage using electron beam melting (EBM) technique to reduce its elastic modulus and compared its spinal fusion efficacy with a PEEK cage in a preclinical sheep anterior cervical fusion model. A porous T i cage possesses a fully interconnected porous structure (porosity: 68 ± 5.3%; pore size: 710 ± 42 μm) and a similar Y oung's modulus as natural bone (2.5 ± 0.2 GPa). When implanted in vivo, the porous T i cage promoted fast bone ingrowth, achieving similar bone volume fraction at 6 months as the PEEK cage without autograft transplantation. Moreover, it promoted better osteointegration with higher degree (2‐10x) of bone‐material binding, demonstrated by histomorphometrical analysis, and significantly higher mechanical stability (P < 0.01), shown by biomechanical testing. The porous T i cage fabricated by EBM could achieve fast bone ingrowth. In addition, it had better osseointegration and superior mechanical stability than the conventional PEEK cage, demonstrating great potential for clinical application.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/aor.12153

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 181

Metadata

Authors
Wu, S., Li, Y., Zhang, Y., Li, X., Yuan, C., Hao, Y., Zhang, Z., & Guo, Z.
Venue
Artificial Organs
Publisher
Wiley
Published
2013-10-22
Volume
37
Issue
12
Pages
E191-201
ISSN
  • 0160-564X (ISSN-L)
  • 1525-1594
OpenAlex
W1929300167
Cited by
181
References
0
FWCI
3.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Porous Titanium‐6 Aluminum‐4 Vanadium Cage Has Better Osseointegration and Less Micromotion Than a Poly‐Ether‐Ether‐Ketone Cage in Sheep Vertebral Fusion. https://app.cochat.ai/papers/10.1111/aor.12153
The paper
Wu, S., Li, Y., Zhang, Y., Li, X., Yuan, C., Hao, Y., Zhang, Z., & Guo, Z. (2013). Porous Titanium‐6 Aluminum‐4 Vanadium Cage Has Better Osseointegration and Less Micromotion Than a Poly‐Ether‐Ether‐Ketone Cage in Sheep Vertebral Fusion. Artificial Organs. https://doi.org/10.1111/aor.12153

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.