The DOI matches its Crossref record.
Porous Titanium‐6 Aluminum‐4 Vanadium Cage Has Better Osseointegration and Less Micromotion Than a Poly‐Ether‐Ether‐Ketone Cage in Sheep Vertebral Fusion
Abstract
Interbody fusion cages made of poly‐ether‐ether‐ketone (PEEK) have been widely used in clinics for spinal disorders treatment; however, they do not integrate well with surrounding bone tissue. T i‐6 A l‐4 V (T i) has demonstrated greater osteoconductivity than PEEK, but the traditional T i cage is generally limited by its much greater elastic modulus (110 GPa) than natural bone (0.05–30 GPa). In this study, we developed a porous T i cage using electron beam melting (EBM) technique to reduce its elastic modulus and compared its spinal fusion efficacy with a PEEK cage in a preclinical sheep anterior cervical fusion model. A porous T i cage possesses a fully interconnected porous structure (porosity: 68 ± 5.3%; pore size: 710 ± 42 μm) and a similar Y oung's modulus as natural bone (2.5 ± 0.2 GPa). When implanted in vivo, the porous T i cage promoted fast bone ingrowth, achieving similar bone volume fraction at 6 months as the PEEK cage without autograft transplantation. Moreover, it promoted better osteointegration with higher degree (2‐10x) of bone‐material binding, demonstrated by histomorphometrical analysis, and significantly higher mechanical stability (P < 0.01), shown by biomechanical testing. The porous T i cage fabricated by EBM could achieve fast bone ingrowth. In addition, it had better osseointegration and superior mechanical stability than the conventional PEEK cage, demonstrating great potential for clinical application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Taniguchi, N., Fujibayashi, S., Takemoto, M., Sasaki, K., Otsuki, B., Nakamura, T., Matsushita, T., Kokubo, T., & Matsuda, S. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2015.10.069 · Cited by 960
Li, S. J., Xu, Q. S., Wang, Z., Hou, W. T., Hao, Y. L., Yang, R., & Murr, L. E. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.06.010 · Cited by 360
Self-citationSynthetic bone: Design by additive manufacturing
Barba, D., Alabort, E., & Reed, R. C. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.07.049 · Cited by 316
Trevisan, F., Calignano, F., Aversa, A., Marchese, G., Lombardi, M., Biamino, S., Ugues, D., & Manfredi, D. (2018) · Journal of Applied Biomaterials & Functional Materials · doi:10.5301/jabfm.5000371 · Cited by 295
Seaman, S., Kerezoudis, P., Bydon, M., Torner, J. C., & Hitchon, P. W. (2017) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2017.06.062 · Cited by 294
Metadata
- Authors
- Wu, S., Li, Y., Zhang, Y., Li, X., Yuan, C., Hao, Y., Zhang, Z., & Guo, Z.
- Venue
- Artificial Organs
- Publisher
- Wiley
- Published
- 2013-10-22
- Volume
- 37
- Issue
- 12
- Pages
- E191-201
- ISSN
- 0160-564X (ISSN-L)
- 1525-1594
- OpenAlex
- W1929300167
- Cited by
- 181
- References
- 0
- FWCI
- 3.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Porous Titanium‐6 Aluminum‐4 Vanadium Cage Has Better Osseointegration and Less Micromotion Than a Poly‐Ether‐Ether‐Ketone Cage in Sheep Vertebral Fusion. https://app.cochat.ai/papers/10.1111/aor.12153
- The paper
- Wu, S., Li, Y., Zhang, Y., Li, X., Yuan, C., Hao, Y., Zhang, Z., & Guo, Z. (2013). Porous Titanium‐6 Aluminum‐4 Vanadium Cage Has Better Osseointegration and Less Micromotion Than a Poly‐Ether‐Ether‐Ketone Cage in Sheep Vertebral Fusion. Artificial Organs. https://doi.org/10.1111/aor.12153
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.