CoChat

Dialysis Complications in Acute Kidney Injury Patients Treated With Prolonged Intermittent Renal Replacement Therapy Sessions Lasting 10 Versus 6 Hours: Results of a Randomized Clinical Trial

Albino, Bianca Ballarin, Balbi, André Luis, Abrão, Juliana Maria Gera, Ponce, Daniela · 2015 · Artificial Organs
Cited by 36

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

P rolonged intermittent renal replacement therapy (PIRRT) has emerged as an alternative to continuous renal replacement therapy in the management of acute kidney injury (AKI) patients. This trial aimed to compare the dialysis complications occurring during different durations of PIRRT sessions in critically ill AKI patients. We included patients older than 18 years with AKI associated with sepsis admitted to the intensive care unit and using noradrenaline doses ranging from 0.3 to 0.7 µg/kg/min. Patients were divided into two groups randomly: in G 1, 6‐h sessions were performed, and in G 2, 10‐h sessions were performed. Seventy‐five patients were treated with 195 PIRRT sessions for 18 consecutive months. The prevalence of hypotension, filter clotting, hypokalemia, and hypophosphatemia was 82.6, 25.3, 20, and 10.6%, respectively. G 1 was composed of 38 patients treated with 100 sessions, whereas G 2 consisted of 37 patients treated with 95 sessions. G 1 and G 2 were similar in male predominance (65.7 vs. 75.6%, P = 0.34), age (63.6 ± 14 vs. 59.9 ± 15.5 years, P = 0.28) and Sequential Organ Failure Assessment score (SOFA; 13.1 ± 2.4 vs. 14.2 ± 3.0, P = 0.2). There was no significant difference between the two groups in hypotension (81.5 vs. 83.7%, P = 0.8), filter clotting (23.6 vs. 27%, P = 0.73), hypokalemia (13.1 vs. 8.1%, P = 0.71), and hypophosphatemia (18.4 vs. 21.6%, P = 0.72). However, the group treated with sessions of 10 h were refractory to clinical measures for hypotension, and dialysis sessions were interrupted more often (9.5 vs. 30.1%, P = 0.03). Metabolic control and fluid balance were similar between G 1 and G 2 (blood urea nitrogen [BUN]: 81 ± 30 vs. 73 ± 33 mg/d L, P = 1.0; delivered Kt/V: 1.09 ± 0.24 vs. 1.26 ± 0.26, P = 0.09; actual ultrafiltration: 1731 ± 818 vs. 2332 ± 947 m L, P = 0.13) and fluid balance (–731 ± 125 vs. −652 ± 141 m L, respectively) . In conclusion, intradialysis hypotension was common in AKI patients treated with PIRRT. There was no difference in the prevalence of dialysis complications in patients undergoing different durations of PIRRT.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/aor.12408

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Albino, B. B., Balbi, A. L., Abrão, J. M. G., & Ponce, D.
Venue
Artificial Organs
Publisher
Wiley
Published
2015-04-10
Volume
39
Issue
5
Pages
423-431
ISSN
  • 0160-564X (ISSN-L)
  • 1525-1594
OpenAlex
W1942298657
Cited by
36
References
1
FWCI
2.49
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.