CoChat

Direct comparison of the specialised blood fibrosis tests FibroMeterV2G and Enhanced Liver Fibrosis score in patients with non‐alcoholic fatty liver disease from tertiary care centres

Guillaume, Maeva, Moal, Valerie, Delabaudiere, Cyrielle, Zuberbuhler, Floraine, Robic, Marie‐Angèle, Lannes, Adrien, Metivier, Sophie, Oberti, Frederic, Gourdy, Pierre, Fouchard‐Hubert, Isabelle, Selves, Janick, Michalak, Sophie, Peron, Jean‐Marie, Cales, Paul, Bureau, Christophe, Boursier, Jerome · 2019 · Alimentary Pharmacology & Therapeutics
Cited by 55

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Summary: Background: The Enhanced Liver Fibrosis score (ELF) and the FibroMeter V2G are two specialized blood fibrosis tests which include direct markers of liver fibrosis. They have been shown to be more accurate than the simple blood fibrosis tests FIB4 and the non‐alcoholic fatty liver disease (NAFLD) fibrosis score (NFS). Aims: To directly compare the accuracies of ELF and FibroMeter V2G for the non‐invasive diagnosis of liver fibrosis in NAFLD. Methods: Four hundred and seventeen patients with biopsy‐proven NAFLD were enrolled from two tertiary care centres. Four blood fibrosis tests were calculated: ELF, FibroMeter V2G, NFS, and FIB4. Advanced fibrosis F3/4 on liver biopsy (NASH CRN scoring) was the primary endpoint. Results: Areas under the receiver operating characteristic (AUROC) curve for advanced fibrosis were not significantly different between the direct markers of liver fibrosis (hyaluronate, PIIINP, TIMP‐1, alpha2‐macroglobulin) and the simple blood fibrosis tests NFS and FIB4. ELF (0.793 ± 0.022) and FibroMeter V2G (0.804 ± 0.021) had significantly higher AUROC than NFS (0.722 ± 0.025, P < .010) and FIB4 (0.739 ± 0.024, P < .020). AUROC for advanced fibrosis and Obuchowski index were not significantly different between ELF and FibroMeter V2G. Algorithms using first ELF or FibroMeter V2G and then liver biopsy in case of undetermined diagnosis provided high diagnostic accuracy for advanced fibrosis: 90% sensitivity, 90% specificity, 93% negative predictive value, 85% positive predictive value, and 90% correct classification. In these algorithms, the rate of liver biopsy was 45.3% with ELF versus 39.3% with FibroMeter V2G (P = .065). Conclusions: ELF and FibroMeter V2G have equal accuracy and perform better than the simple FIB4 and NFS tests for the non‐invasive diagnosis of advanced liver fibrosis in patients with NAFLD from tertiary care centres.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/apt.15529

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 55

Metadata

Authors
Guillaume, M., Moal, V., Delabaudiere, C., Zuberbuhler, F., Robic, M., Lannes, A., Metivier, S., Oberti, F., Gourdy, P., Fouchard‐Hubert, I., Selves, J., Michalak, S., Peron, J., Cales, P., Bureau, C., & Boursier, J.
Venue
Alimentary Pharmacology & Therapeutics
Publisher
Wiley
Published
2019-10-15
Volume
50
Issue
11-12
Pages
1214-1222
ISSN
  • 0269-2813 (ISSN-L)
  • 1365-2036
OpenAlex
W2980347749
Cited by
55
References
11
FWCI
5.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.