Aims: Liver‐enriched microRNA‐122 (miR‐122) is a novel circulating biomarker for drug‐induced liver injury (DILI). To date, miR‐122 has been measured in serum or plasma venous samples. If miR‐122 could be measured in capillary blood obtained from a finger prick it would facilitate point‐of‐care testing, such as in resource‐limited settings that have a high burden of DILI. Methods: In this study, in healthy subjects, miR‐122 was measured by polymerase chain reaction in three capillary blood drops taken from different fingers and in venous blood and plasma (n = 20). miR‐122 was also measured in capillary blood obtained from patients with DILI (n = 8). Results: Circulating miR‐122 could be readily measured in a capillary blood drop in healthy volunteers with a median (interquartile range) cycle threshold (Ct) of 32.6 (31.1–34.2). The coefficient of variation for intraindividual variability across replicate blood drops was 49.9%. Capillary miR‐122 faithfully reflected the concentration in venous blood and plasma (Pearson R = 0.89, P < 0.0001; 0.88, P < 0.0001, respectively). miR‐122 was 86‐fold higher in DILI patients [median value 1.0 × 10 8 (interquartile range 1.89 × 10 7–3.04 × 10 9) copies/blood drop] compared to healthy subjects [1.85 × 10 6 (4.92 × 10 5–5.88 × 10 6) copies/blood drop]. Receiver operator characteristic analysis demonstrated that capillary miR‐122 sensitively and specifically reported DILI (area under the curve: 0.96, P = 0.0002). Conclusion: This work supports the potential use of miR‐122 as biomarker of human DILI when measured in a capillary blood drop. With development across DILI aetiologies, this could be used by novel point‐of‐care technologies to produce a minimally invasive, near‐patient, diagnostic test.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/bcp.13282

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Vliegenthart, A. D. B., Berends, C., Potter, C. M. J., Kersaudy‐Kerhoas, M., & Dear, J. W.
Venue
British Journal of Clinical Pharmacology
Publisher
Wiley
Published
2017-04-05
Volume
83
Issue
9
Pages
2027-2033
ISSN
  • 0306-5251 (ISSN-L)
  • 1365-2125
OpenAlex
W2593387976
Cited by
38
References
6
FWCI
6.03
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.