Biofilm formation on the surface of modern implant abutment materials
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Objective: To investigate the formation of biofilms on the surface of materials applied for the fabrication of implant abutments. Material and methods: Specimens were prepared from the implant abutment materials titanium, zirconia, and polyetheretherketone (PEEK); specimens made from polymethylmethacrylate (PMMA) were used for reference. All specimens were polished to high gloss using silicon carbide paper; surface roughness was determined using profilometry, and surface free energy was calculated from contact angle measurements. After the simulation of salivary pellicle formation, multispecies biofilm formation was initiated by exposing the specimens to a suspension of Streptococcus gordonii, Streptococcus mutans, Actinomyces naeslundii, and Candida albicans for either 20 or 44 h. Viable microbial biomass adherent to the specimens (n = 10 per material and incubation time) and the percentage of dead microorganisms in the different biofilms (n = 5, accordingly) were determined. Results: Significantly lower surface roughness was identified for PEEK and PMMA than for zirconia and titanium (P < 0.001); surface free energy was significantly lower for zirconia than for PEEK (P = 0.038). Significantly higher viable biomass and a significantly higher percentage of dead microorganisms were identified after 44 h than after 20 h of biofilm formation (P < 0.001, respectively); after 20 h, PEEK surfaces harbored significantly lower viable biomass than the surfaces of the other materials (P < 0.0125). After 44 h, significant differences were identified in the percentage of dead microorganisms organized in the biofilms on the different materials (P = 0.012). Conclusions: Within the limitations of a laboratory study, the results suggest that biofilm formation on the surface of PEEK is equal or lower than on the surface of conventionally applied abutment materials such as zirconia and titanium. However, clinical studies are necessary to corroborate these preliminary results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bollenl, C. M. L., Lambrechts, P., & Quirynen, M. (1997) · Dental Materials · doi:10.1016/s0109-5641(97)80038-3 · Cited by 1,911
Oral multispecies biofilm development and the key role of cell–cell distance
Kolenbrander, P. E., Palmer, R. J., Periasamy, S., & Jakubovics, N. S. (2010) · Nature Reviews Microbiology · doi:10.1038/nrmicro2381 · Cited by 1,309
Bamford, C. V., d'Mello, A., Nobbs, A. H., Dutton, L. C., Vickerman, M. M., & Jenkinson, H. F. (2009) · Infection and Immunity · doi:10.1128/iai.00438-09 · Cited by 291
Cited by
Applications of polyetheretherketone (PEEK) in oral implantology and prosthodontics
Najeeb, S., Zafar, M. S., Khurshid, Z., & Siddiqui, F. (2016) · Journal of Prosthodontic Research · doi:10.1016/j.jpor.2015.10.001 · Cited by 897
Metadata
- Authors
- Hahnel, S., Wieser, A., Lang, R., & Rosentritt, M.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 2014-07-24
- Volume
- 26
- Issue
- 11
- Pages
- 1297-1301
- ISSN
- 0905-7161 (ISSN-L)
- 1600-0501
- OpenAlex
- W2137976098
- Cited by
- 201
- References
- 3
- FWCI
- 10.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.