Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 288

The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.

Implant placement and loading protocols in partially edentulous patients: A systematic review

Open access
Gallucci, German O., Hamilton, Adam, Zhou, Wenjie, Buser, Daniel, Chen, Stephen·2018·Clinical Oral Implants Research

Abstract

Objectives: To systematically review the evidence for the clinical outcome of fixed implant prostheses treated with different combinations of implant placement and loading protocols in partially edentulous patients. Materials and methods: An electronic search was performed in Medline, Embase, and Central to identify studies investigating the outcome of implants subjected to immediate placement + immediate restoration/loading (Type 1A), immediate placement + early loading (Type 1B), immediate placement + conventional loading (Type 1C), early placement + immediate restoration/loading (Type 2‐3A), early placement + early loading (Type 2‐3B), early placement + conventional loading (Type 2‐3C), late placement + immediate restoration/loading (Type 4A), late placement + early loading (Type 4B), late placement + conventional loading (Type 4C) with implant‐supported fixed dental prostheses (IFDP s) in partially edentulous patients. Only human studies with at least 10 cases and a minimum follow‐up time of 12 months, reporting on solid‐screw‐type implants with rough surfaces and an intra‐osseous diameter between 3 and 6 mm, were included. A cumulative survival rate for each type of the implant placement and loading protocols was weighted by the duration of follow‐up and number of implants. Results: The search provided 5,248 titles from which 2,362 abstracts and 449 full‐text articles were screened. A total of 69 publications that comprised 23 comparative studies (15 randomized controlled trials, 7 controlled clinical trials) and 47 noncomparative studies (34 prospective cohort studies, 13 retrospective cohort studies) were included for analysis. Considerable heterogeneity in study design was found, and therefore, a meta‐analysis of controlled studies was not possible. The weighted cumulative survival rate of each type of placement and loading protocol was 98.4% (Type 1A), 98.2% (Type 1B), 96.0% (Type 1C), 100% (Type 2‐3B), 96.3% (Type 2‐3C), 97.9% (Type 4A), 98.3% (Type 4B), and 97.7% (Type 4C). Type 1C, Type 2‐3C, Type 4B, and Type 4C were scientifically and clinically validated (SCV). Type 1A, Type 1B, and Type 4A were clinically documented (CD), and Type 2‐3A and Type 2‐3B were clinically insufficiently documented (CID). Conclusions: Evaluating outcomes in oral implantology by combining the placement and loading protocols are paramount. The selected loading protocol appears to influence the outcome of immediate implant placement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/clr.13276

Cites

49 of 49 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 49 references

Cited by

See all 288

Metadata

Authors
Gallucci, G. O., Hamilton, A., Zhou, W., Buser, D., & Chen, S.
Venue
Clinical Oral Implants Research
Publisher
Wiley
Published
2018-10
Volume
29
Issue
S16
Pages
106-134
ISSN
  • 0905-7161 (ISSN-L)
  • 1600-0501
OpenAlex
W2897065292
Cited by
288
References
49
FWCI
4.32
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Implant placement and loading protocols in partially edentulous patients: A systematic review. https://app.cochat.ai/papers/10.1111/clr.13276
The paper
Gallucci, G. O., Hamilton, A., Zhou, W., Buser, D., & Chen, S. (2018). Implant placement and loading protocols in partially edentulous patients: A systematic review. Clinical Oral Implants Research. https://doi.org/10.1111/clr.13276

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.