Choroidal changes in human myopia: insights from optical coherence tomography imaging
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The choroid is a vascular tissue which plays a range of critical roles in the normal physiology of the eye, such as supplying the outer retina with oxygen and nutrients and the regulation of intraocular pressure. There is also substantial evidence, particularly from animal studies, that the choroid plays an important role in the regulation of eye growth and the development of common refractive errors like myopia. In recent years, advances in optical coherence tomography technology have improved our ability to image and measure the choroid in the human eye. Research using this technology over the past decade has dramatically improved our knowledge of the normal choroid, and its potential role in the regulation of eye growth and refractive error development. This review aims to provide an overview of recent work examining the normal human choroid, its changes with myopia and the possible role of the choroid in the mechanism regulating eye growth. Studies have demonstrated that choroidal thinning accompanies the development and progression of myopia, and have established a close link between eye growth and choroidal thickness changes. Dramatic thinning of the choroid is seen with high myopia, and associations are also observed between choroidal thinning and reduced vision, and the development of retinal pathology associated with high myopia. In the short-term, environmental factors known to be associated with myopia development and more rapid eye growth typically lead to a thinning of the choroid, whereas factors linked to a slowing of eye growth are typically associated with short-term choroidal thickening. Collectively, these findings suggest that the choroid is an important biomarker of eye growth in the human eye, and additional research to better understand the human choroid is likely to further our knowledge of the signals and pathways regulating eye growth, myopia development and progression.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In a Matter of Minutes, the Eye Can Know Which Way to Grow
Zhu, X., Park, T. W., Winawer, J., & Wallman, J. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-0956 · Cited by 179
Cited by
IMI—The Dynamic Choroid: New Insights, Challenges, and Potential Significance for Human Myopia
Ostrin, L. A., Harb, E., Nickla, D. L., Read, S. A., Alonso-Caneiro, D., Schroedl, F., Kaser-Eichberger, A., Zhou, X., & Wildsoet, C. F. (2023) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.64.6.4 · Cited by 190
Self-citation
Metadata
- Authors
- Read, S. A., Fuss, J. A., Vincent, S. J., Collins, M. J., & Alonso‐caneiro, D.
- Venue
- Clinical and Experimental Optometry
- Publisher
- Informa UK Limited
- Published
- 2019-05-01
- Volume
- 102
- Issue
- 3
- Pages
- 270-285
- ISSN
- 0816-4622 (ISSN-L)
- 1444-0938
- OpenAlex
- W2904540960
- Cited by
- 163
- References
- 1
- FWCI
- 6.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.