Cited by 179Ophthalmology and Visual Impairment StudiesVisual perception and processing mechanismsRetinal Diseases and Treatments

In a Matter of Minutes, the Eye Can Know Which Way to Grow

Zhu, Xiaoying, Park, Tae Woo, Winawer, Jonathan, Wallman, Josh·2005·Investigative Opthalmology & Visual Science

Abstract

Purpose The fitting of chick eyes with positive or negative lenses causes eye growth to decelerate or accelerate, respectively, thereby minimizing the imposed blur. This study was conducted to determine whether the eye can initially assess the correct direction of growth or whether it relies on trial and error, reversing its direction if the magnitude of blur increases. The rapid changes in choroidal thickness in response to brief periods of defocus were measured. Methods After their eyes were measured by ultrasound biometry, chicks wore either a +10-D lens over one eye for 10 minutes while restrained in the center of a 60-cm drum (to ensure myopic blur), or a negative lens (-7 or -8.6 D) over one eye for 10 minutes or 1 hour in a normal cage environment. They were then kept in darkness until they were remeasured 2 hours, 1 day, or 2 days after the first measurement. Other chicks wore +10 or -8.6-D lenses briefly and were measured several times over the next 7 hours in darkness. Results Wearing positive or negative lenses for only 10 minutes produced significantly different effects on choroidal thickness measured 2 hours later. Wearing positive lenses for 10 minutes caused an increase in choroidal thickness (in 28 of 32 eyes) and a concomitant decrease in vitreous chamber depth, relative to the amount of change in the untreated fellow eye over the same period. Wearing negative lenses for 1 hour caused significant changes in the opposite direction. Wearing lenses for 2 hours r…

Integrity signals

Registry

Crossref · 10.1167/iovs.04-0956

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Choroidal thickness changes in response to imposed myopic or hyperopic defocus occur within an hour.

    “Because choroidal thickness changes in response to imposed myopic or hyperopic defocus occur within an hour (Zhu, Park, Winawer, & Wallman, 2005), we reasoned that if the choroidal changes were a response to the flicker itself, we should see a similarly rapid response”

    From Chicks use changes in luminance and chromatic contrast as indicators of the sign of defocus (2012) · cites this paper as Zhu, Park, Winawer, & Wallman, 2005

Cited by

Sorted by citations

Authors
Zhu, X., Park, T. W., Winawer, J., & Wallman, J.
Affiliations
City College of New York (US)
Venue
Investigative Opthalmology & Visual Science
Published
2005-07-01
Volume
46
Issue
7
Pages
2238
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2083527326
Cited by
179
References
0
Citations by year
2026: 4 · 2025: 5 · 2024: 16 · 2023: 9 · 2022: 7 · 2021: 18 · 2020: 9 · 2019: 12 · 2018: 8 · 2017: 5 · 2016: 8 · 2015: 10 · 2014: 5 · 2013: 17 · 2012: 6
FWCI
3.56
Type
journal article
Language
en
Open access
closed
Locations
  • Investigative Ophthalmology & Visual Science (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Eye Institute (EY-02727)
  • National Center for Research Resources (RR-03060)
Topics
  • Health Sciences › Medicine › Epidemiology › Ophthalmology and Visual Impairment Studies
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Visual perception and processing mechanisms
  • Health Sciences › Medicine › Ophthalmology › Retinal Diseases and Treatments
Keywords
eye growth, myopia, hyperopia, defocus, choroidal thickness, chicks, lens wear, vitreous chamber depth, ocular elongation
MeSH terms
Accommodation, Ocular, Animals, Chickens, Choroid, Contact Lenses, Dark Adaptation, Disease Models, Animal, Eye, Hyperopia, Myopia, Ocular Physiological Phenomena, Refraction, Ocular, Time Factors, Vitreous Body

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review