CoChat

Assessing the limit of detection of Fourier‐transform infrared spectroscopy and immunoassay strips for fentanyl in a real‐world setting

McCrae, Karen, Tobias, Samuel, Grant, Cameron, Lysyshyn, Mark, Laing, Richard, Wood, Evan, Ti, Lianping · 2020 · Drug and Alcohol Review
Cited by 98

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Introduction and Aims: Drug checking is a harm reduction intervention increasingly used in the context of the opioid overdose epidemic. The aim of the study was to determine the limit of detection for fentanyl of two point‐of‐care drug checking technologies. Design and Methods: Samples tested at point‐of‐care using Bruker Fourier transform infrared (FTIR) spectroscopy and BTNX fentanyl immunoassay strips were sent for confirmatory laboratory analysis using quantitative nuclear magnetic resonance (qNMR) spectroscopy. Concentrations by weight were determined and compared to results obtained with point‐of‐care methods. Results: In total, 283 samples were sent for qNMR analysis; among these, 173 (61.1%) tested positive for fentanyl. As determined by qNMR, fentanyl concentration by weight ranged from 1% to 91%. Among these 173 samples, fentanyl was not detected in 30 (17.3%) samples by FTIR and in 4 (2.3%) samples by test strip. Samples containing fentanyl that went undetected by FTIR had concentrations ≤10%. The four samples containing fentanyl that went undetected by test strip had concentrations ≤5% (i.e. 1%, 3%, 4%, 5%). Discussion and Conclusions: Fentanyl immunoassay strips were able to consistently detect the presence of fentanyl in samples at lower concentrations than FTIR spectroscopy. Given that FTIR spectroscopy is able to quantify content, mixture and concentrations on an array of compounds beyond just fentanyl but requires concentrations generally greater than 10%, these findings provide evidence for use of FTIR spectroscopy and immunoassay strips in combination to compensate for the limitations of each technology alone.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/dar.13004

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 98

Metadata

Authors
McCrae, K., Tobias, S., Grant, C., Lysyshyn, M., Laing, R., Wood, E., & Ti, L.
Venue
Drug and Alcohol Review
Publisher
Wiley
Published
2019-11-19
Volume
39
Issue
1
Pages
98-102
ISSN
  • 0959-5236 (ISSN-L)
  • 1465-3362
OpenAlex
W2990407838
Cited by
98
References
3
FWCI
16.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessing the limit of detection of Fourier‐transform infrared spectroscopy and immunoassay strips for fentanyl in a real‐world setting. https://app.cochat.ai/papers/10.1111/dar.13004
The paper
McCrae, K., Tobias, S., Grant, C., Lysyshyn, M., Laing, R., Wood, E., & Ti, L. (2020). Assessing the limit of detection of Fourier‐transform infrared spectroscopy and immunoassay strips for fentanyl in a real‐world setting. Drug and Alcohol Review. https://doi.org/10.1111/dar.13004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.