CoChat

Validation study for development of the Japan NBI Expert Team classification of colorectal lesions

Iwatate, Mineo, Sano, Yasushi, Tanaka, Shinji, Kudo, Shin‐ei, Saito, Shoichi, Matsuda, Takahisa, Wada, Yoshiki, Fujii, Takahiro, Ikematsu, Hiroaki, Uraoka, Toshio, Kobayashi, Nozomu, Nakamura, Hisashi, Hotta, Kinichi, Horimatsu, Takahiro, Sakamoto, Naoto, Fu, Kuang‐I, Tsuruta, Osamu, Kawano, Hiroshi, Kashida, Hiroshi, Takeuchi, Yoji, Machida, Hirohisa, Kusaka, Toshihiro, Yoshida, Naohisa, Hirata, Ichiro, Terai, Takeshi, Yamano, Hiro‐o, Nakajima, Takeshi, Sakamoto, Taku, Yamaguchi, Yuichiro, Tamai, Naoto, Nakano, Naoko, Hayashi, Nana, Oka, Shiro, Ishikawa, Hideki, Murakami, Yoshitaka, Yoshida, Shigeaki, Saito, Yutaka, The Japan NBI Expert Team (JNET) · 2018 · Digestive Endoscopy
Cited by 141

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background and Aim: The Japan narrow‐band imaging (NBI) Expert Team (JNET) was organized to unify four previous magnifying NBI classifications (the Sano, Hiroshima, Showa, and Jikei classifications). The JNET working group created criteria (referred to as the NBI scale) for evaluation of vessel pattern (VP) and surface pattern (SP). We conducted a multicenter validation study of the NBI scale to develop the JNET classification of colorectal lesions. Methods: Twenty‐five expert JNET colonoscopists read 100 still NBI images with and without magnification on the web to evaluate the NBI findings and necessity of the each criterion for the final diagnosis. Results: Surface pattern in magnifying NBI images was necessary for diagnosis of polyps in more than 60% of cases, whereas VP was required in around 90%. Univariate/multivariate analysis of candidate findings in the NBI scale identified three for type 2B (variable caliber of vessels, irregular distribution of vessels, and irregular or obscure surface pattern), and three for type 3 (loose vessel area, interruption of thick vessel, and amorphous areas of surface pattern). Evaluation of the diagnostic performance for these three findings in combination showed that the sensitivity for types 2B and 3 was highest (44.9% and 54.7%, respectively), and that the specificity for type 3 was acceptable (97.4%) when any one of the three findings was evident. We found that the macroscopic type (polypoid or non‐polypoid) had a minor influence on the key diagnostic performance for types 2B and 3. Conclusion: Based on the present data, we reached a consensus for developing the JNET classification.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/den.13065

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 141

Metadata

Authors
Iwatate, M., Sano, Y., Tanaka, S., Kudo, S., Saito, S., Matsuda, T., Wada, Y., Fujii, T., Ikematsu, H., Uraoka, T., Kobayashi, N., Nakamura, H., Hotta, K., Horimatsu, T., Sakamoto, N., Fu, K., Tsuruta, O., Kawano, H., Kashida, H., Takeuchi, Y., Machida, H., Kusaka, T., Yoshida, N., Hirata, I., Terai, T., Yamano, H., Nakajima, T., Sakamoto, T., Yamaguchi, Y., Tamai, N., Nakano, N., Hayashi, N., Oka, S., Ishikawa, H., Murakami, Y., Yoshida, S., Saito, Y., & The Japan NBI Expert Team (JNET)
Venue
Digestive Endoscopy
Publisher
Wiley
Published
2018-06-26
Volume
30
Issue
5
Pages
642-651
ISSN
  • 0915-5635 (ISSN-L)
  • 1443-1661
OpenAlex
W2795192922
Cited by
141
References
1
FWCI
5.06
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.