CoChat

Impact of an artificial intelligence‐aided endoscopic diagnosis system on improving endoscopy quality for trainees in colonoscopy: Prospective, randomized, multicenter study

Open access
Yamaguchi, Daisuke, Shimoda, Ryo, Miyahara, Koichi, Yukimoto, Takahiro, Sakata, Yasuhisa, Takamori, Ayako, Mizuta, Yumi, Fujimura, Yutaro, Inoue, Suma, Tomonaga, Michito, Ogino, Yuya, Eguchi, Kohei, Ikeda, Kei, Tanaka, Yuichiro, Takedomi, Hironobu, Hidaka, Hidenori, Akutagawa, Takashi, Tsuruoka, Nanae, Noda, Takahiro, Tsunada, Seiji, Esaki, Motohiro · 2024 · Digestive Endoscopy
Cited by 78

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Objective: This study was performed to evaluate whether the use of CAD EYE (Fujifilm, Tokyo, Japan) for colonoscopy improves colonoscopy quality in gastroenterology trainees. Methods: The patients in this multicenter randomized controlled trial were divided into Group A (observation using CAD EYE) and Group B (standard observation). Six trainees performed colonoscopies using a back‐to‐back method in pairs with gastroenterology experts. The primary end‐point was the trainees' adenoma detection rate (ADR), and the secondary end‐points were the trainees' adenoma miss rate (AMR) and Assessment of Competency in Endoscopy (ACE) tool scores. Each trainee's learning curve was evaluated using a cumulative sum (CUSUM) control chart. Results: We analyzed data for 231 patients (Group A, n = 113; Group B, n = 118). The ADR was not significantly different between the two groups. Group A had a significantly lower AMR (25.6% vs. 38.6%, P = 0.033) and number of missed adenomas per patient (0.5 vs. 0.9, P = 0.004) than Group B. Group A also had significantly higher ACE tool scores for pathology identification (2.26 vs. 2.07, P = 0.030) and interpretation and identification of pathology location (2.18 vs. 2.00, P = 0.038). For the CUSUM learning curve, Group A showed a trend toward a lower number of cases of missed multiple adenomas by the six trainees. Conclusion: CAD EYE did not improve ADR but decreased the AMR and improved the ability to accurately locate and identify colorectal adenomas. CAD EYE can be assumed to be beneficial for improving colonoscopy quality in gastroenterology trainees. Trial registration: University Hospital Medical Information Network Clinical Trials Registry (UMIN000044031).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/den.14573

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 78

Metadata

Authors
Yamaguchi, D., Shimoda, R., Miyahara, K., Yukimoto, T., Sakata, Y., Takamori, A., Mizuta, Y., Fujimura, Y., Inoue, S., Tomonaga, M., Ogino, Y., Eguchi, K., Ikeda, K., Tanaka, Y., Takedomi, H., Hidaka, H., Akutagawa, T., Tsuruoka, N., Noda, T., Tsunada, S., & Esaki, M.
Venue
Digestive Endoscopy
Publisher
Wiley
Published
2023-05-29
Volume
36
Issue
1
Pages
40-48
ISSN
  • 0915-5635 (ISSN-L)
  • 1443-1661
OpenAlex
W4366463000
Cited by
78
References
5
FWCI
8.08
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Impact of an artificial intelligence‐aided endoscopic diagnosis system on improving endoscopy quality for trainees in colonoscopy: Prospective, randomized, multicenter study. https://app.cochat.ai/papers/10.1111/den.14573
The paper
Yamaguchi, D., Shimoda, R., Miyahara, K., Yukimoto, T., Sakata, Y., Takamori, A., Mizuta, Y., Fujimura, Y., Inoue, S., Tomonaga, M., Ogino, Y., Eguchi, K., Ikeda, K., Tanaka, Y., Takedomi, H., Hidaka, H., Akutagawa, T., Tsuruoka, N., Noda, T., . . . Esaki, M. (2024). Impact of an artificial intelligence‐aided endoscopic diagnosis system on improving endoscopy quality for trainees in colonoscopy: Prospective, randomized, multicenter study. Digestive Endoscopy. https://doi.org/10.1111/den.14573

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.