Comparison of insulin degludec with insulin glargine in insulin‐naive subjects with Type 2 diabetes: a 2‐year randomized, treat‐to‐target trial
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Aims: The aim of this study was to compare long‐term safety and efficacy of the basal insulin analogue degludec with glargine in insulin‐naive subjects with Type 2 diabetes. Methods: This open‐label trial included a 52‐week core period followed by a 52‐week extension. Participants were randomized 3:1 to once‐daily degludec or glargine, administered with metformin ± dipeptidyl peptidase‐4 inhibitors. Basal insulin was titrated to target pre‐breakfast plasma glucose 3.9–4.9 mmol/l. Results: At end of treatment (104 weeks), mean HbA 1c reductions were similar for degludec and glargine; estimated treatment difference between degludec and glargine was 1 mmol/mol (95% CI −1 to 3) [0.07% (95% CI −0.07 to 0.22)], P = 0.339 in the extension trial set (degludec 551, glargine 174), comprising subjects who completed core trial and continued into the extension trial. Overall confirmed hypoglycaemia rates (1.72 vs. 2.05 episodes/patient‐year), rates of adverse events possibly or probably related to trial product (0.19 events/patient‐year), weight gain (2.7 vs. 2.4 kg) and mean daily insulin doses (0.63 U/kg) were similar between treatments in the safety analysis set (degludec 766, glargine 257) comprising all treated subjects. Rates of nocturnal confirmed hypoglycaemia (0.27 vs. 0.46 episodes/patient‐year; P = 0.002) and severe hypoglycaemia (0.006 vs. 0.021 episodes/patient‐year, P = 0.023) were significantly lower with degludec for the safety analysis set (analysis based on intention‐to‐treat full analysis set comprising all randomized subjects). Conclusions: In Type 2 diabetes, insulin degludec in combination with oral anti‐diabetic drugs, safely and effectively improves long‐term glycaemic control, with a significantly lower risk of nocturnal hypoglycaemia as compared with glargine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hypoglycaemia: the limiting factor in the glycaemic management of type I and type II diabetes.
Cryer, P. (2002) · Diabetologia · doi:10.1007/s00125-002-0822-9 · Cited by 794
Design of the Novel Protraction Mechanism of Insulin Degludec, an Ultra-long-Acting Basal Insulin
Jonassen, I., Havelund, S., Hoeg-Jensen, T., Steensgaard, D. B., Wahlund, P.-O., & Ribel, U. (2012) · Pharmaceutical Research · doi:10.1007/s11095-012-0739-z · Cited by 448
Heise, T., Hermanski, L., Nosek, L., Feldman, A., Rasmussen, S., & Haahr, H. (2012) · Diabetes, Obesity and Metabolism · doi:10.1111/j.1463-1326.2012.01627.x · Cited by 397
Insulin Degludec Versus Insulin Glargine in Insulin-Naive Patients With Type 2 Diabetes
Zinman, B., Philis-Tsimikas, A., Cariou, B., Handelsman, Y., Rodbard, H. W., Johansen, T., Endahl, L., Mathieu, C., & on behalf of the NN1250-3579 (BEGIN Once Long) Trial Investigators (2012) · Diabetes Care · doi:10.2337/dc12-1205 · Cited by 336
Self-citationUltra‐long‐acting insulin degludec has a flat and stable glucose‐lowering effect in type 2 diabetes
Heise, T., Nosek, L., Bøttcher, S. G., Hastrup, H., & Haahr, H. (2012) · Diabetes, Obesity and Metabolism · doi:10.1111/j.1463-1326.2012.01638.x · Cited by 331
Jabbour, S. (2008) · International Journal of Clinical Practice · doi:10.1111/j.1742-1241.2008.01757.x · Cited by 44
Cited by
9. Pharmacologic Approaches to Glycemic Treatment: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s009 · Cited by 1,555
9. Pharmacologic Approaches to Glycemic Treatment: Standards of Medical Care in Diabetes—2021
American Diabetes Association (2021) · Diabetes Care · doi:10.2337/dc21-s009 · Cited by 972
9. Pharmacologic Approaches to Glycemic Treatment: Standards of Medical Care in Diabetes—2020
American Diabetes Association (2020) · Diabetes Care · doi:10.2337/dc20-s009 · Cited by 914
9. Pharmacologic Approaches to Glycemic Treatment: Standards of Care in Diabetes—2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s009 · Cited by 851
9. Pharmacologic Approaches to Glycemic Treatment: Standards of Medical Care in Diabetes—2019
American Diabetes Association (2019) · Diabetes Care · doi:10.2337/dc19-s009 · Cited by 739
Metadata
- Authors
- Rodbard, H. W., Cariou, B., Zinman, B., Handelsman, Y., Philis‐Tsimikas, A., Skjøth, T. V., Rana, A., Mathieu, C., & The BEGIN Once Long Trial Investigators
- Venue
- Diabetic Medicine
- Publisher
- Wiley
- Published
- 2013-09-30
- Volume
- 30
- Issue
- 11
- Pages
- 1298-1304
- ISSN
- 0742-3071 (ISSN-L)
- 1464-5491
- OpenAlex
- W1981378897
- Cited by
- 89
- References
- 6
- FWCI
- 9.91
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.