CoChat

Performance and safety of an integrated bihormonal artificial pancreas for fully automated glucose control at home

Open access
Blauw, H., van Bon, A. C., Koops, R., DeVries, J. H., , on behalf of the PCDIAB consortium · 2016 · Diabetes, Obesity and Metabolism
Cited by 115

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Aims: To assess the performance and safety of an integrated bihormonal artificial pancreas system consisting of one wearable device and two wireless glucose sensor transmitters during short‐term daily use at home. Methods: Adult patients with type 1 diabetes using an insulin pump were invited to enrol in this randomized crossover study. Treatment with the artificial pancreas started with a day and night in the clinical research centre, followed by 3 days at home. The control period consisted of 4 days of insulin pump therapy at home with blinded continuous glucose monitoring for data collection. Days 2–4 were predefined as the analysis period, with median glucose as the primary outcome. Results: A total of 10 patients completed the study. The median [interquartile range ( IQR )] glucose level was similar for the two treatments [7.3 (7.0–7.6) mmol/l for the artificial pancreas vs. 7.7 (7.0–9.0) mmol/l for the control; p = 0.123]. The median ( IQR ) percentage of time spent in euglycaemia (3.9–10 mmol/l) was longer during use of the artificial pancreas [84.7 (82.2–87.8)% for the artificial pancreas vs. 68.5 (57.9–83.6)% for the control; p = 0.007]. Time in hypoglycaemia was 1.3 (0.2–3.2)% for the artificial pancreas and 2.4 (0.4–10.3)% for the control treatment (p = 0.139). Separate analysis of daytime and night‐time showed that the improvements were mainly achieved during the night. Conclusions: The results of this pilot study suggest that our integrated artificial pancreas provides better glucose control than insulin pump therapy in patients with type 1 diabetes at home and that the treatment is safe.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/dom.12663

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 115

Metadata

Authors
Blauw, H., van Bon, A. C., Koops, R., DeVries, J. H., & O. B. O. T. P. C.
Venue
Diabetes, Obesity and Metabolism
Publisher
Wiley
Published
2016-04-25
Volume
18
Issue
7
Pages
671-677
ISSN
  • 1462-8902 (ISSN-L)
  • 1463-1326
OpenAlex
W2306119192
Cited by
115
References
2
FWCI
15.59
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Performance and safety of an integrated bihormonal artificial pancreas for fully automated glucose control at home. https://app.cochat.ai/papers/10.1111/dom.12663
The paper
Blauw, H., van Bon, A. C., Koops, R., DeVries, J. H., & O. B. O. T. P. C. (2016). Performance and safety of an integrated bihormonal artificial pancreas for fully automated glucose control at home. Diabetes, Obesity and Metabolism. https://doi.org/10.1111/dom.12663

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.