Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Home Use of an Artificial Beta Cell in Type 1 Diabetes

Open access

Abstract

BACKGROUND: The feasibility, safety, and efficacy of prolonged use of an artificial beta cell (closed-loop insulin-delivery system) in the home setting have not been established. METHODS: In two multicenter, crossover, randomized, controlled studies conducted under free-living home conditions, we compared closed-loop insulin delivery with sensor-augmented pump therapy in 58 patients with type 1 diabetes. The closed-loop system was used day and night by 33 adults and overnight by 25 children and adolescents. Participants used the closed-loop system for a 12-week period and sensor-augmented pump therapy (control) for a similar period. The primary end point was the proportion of time that the glucose level was between 70 mg and 180 mg per deciliter for adults and between 70 mg and 145 mg per deciliter for children and adolescents. RESULTS: Among adults, the proportion of time that the glucose level was in the target range was 11.0 percentage points (95% confidence interval [CI], 8.1 to 13.8) greater with the use of the closed-loop system day and night than with control therapy (P<0.001). The mean glucose level was lower during the closed-loop phase than during the control phase (difference, -11 mg per deciliter; 95% CI, -17 to -6; P<0.001), as were the area under the curve for the period when the glucose level was less than 63 mg per deciliter (39% lower; 95% CI, 24 to 51; P<0.001) and the mean glycated hemoglobin level (difference, -0.3%; 95% CI, -0.5 to -0.1; P=0.002). Among children and adolescents, the proportion of time with the nighttime glucose level in the target range was higher during the closed-loop phase than during the control phase (by 24.7 percentage points; 95% CI, 20.6 to 28.7; P<0.001), and the mean nighttime glucose level was lower (difference, -29 mg per deciliter; 95% CI, -39 to -20; P<0.001). The area under the curve for the period in which the day-and-night glucose levels were less than 63 mg per deciliter was lower by 42% (95% CI, 4 to 65; P=0.03). Three severe hypoglycemic episodes occurred during the closed-loop phase when the closed-loop system was not in use. CONCLUSIONS: Among patients with type 1 diabetes, 12-week use of a closed-loop system, as compared with sensor-augmented pump therapy, improved glucose control, reduced hypoglycemia, and, in adults, resulted in a lower glycated hemoglobin level. (Funded by the JDRF and others; AP@home04 and APCam08 ClinicalTrials.gov numbers, NCT01961622 and NCT01778348.).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejmoa1509351

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Cited by

See all 454

Metadata

Authors
Thabit, H., Tauschmann, M., Allen, J. M., Leelarathna, L., Hartnell, S., Wilinska, M. E., Acerini, C. L., Dellweg, S., Benesch, C., Heinemann, L., Mader, J. K., Holzer, M., Kojzar, H., Exall, J., Yong, J., Pichierri, J., Barnard, K. D., Kollman, C., Cheng, P., Hindmarsh, P. C., Campbell, F. M., Arnolds, S., Pieber, T. R., Evans, M. L., Dunger, D. B., & Hovorka, R.
Affiliations
  • University of Cambridge (GB)
  • Cambridge University Hospitals NHS Foundation Trust (GB)
  • Profil Institute for Metabolic Research (DE)
  • Medical University of Graz (AT)
  • Leeds Teaching Hospitals NHS Trust (GB)
  • University College Hospital (GB)
  • Bournemouth University (GB)
  • Jaeb Center for Health Research (US)
Venue
New England Journal of Medicine
Published
2015-11-26
Volume
373
Issue
22
Pages
2129-2140
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2332531077
Cited by
450
References
29
Citations by year
2026: 9 · 2025: 12 · 2024: 23 · 2023: 29 · 2022: 31 · 2021: 43 · 2020: 34 · 2019: 49 · 2018: 71 · 2017: 71 · 2016: 68 · 2015: 10
FWCI
63.45
Type
journal article
Language
en
Open access
Locations
  • New England Journal of Medicine (publishedVersion)
  • PubMed (publishedVersion)
  • Research Explorer (The University of Manchester) (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
  • Apollo (University of Cambridge) (submittedVersion)
  • UCL Discovery (University College London) (submittedVersion)
  • UEA Digital Repository (University of East Anglia) (submittedVersion)
Funders
  • Wellcome Trust (100574, 100574/Z/12/Z)
  • National Institute for Health and Care Research (NF-SI-0508-10274, NF-SI-0513-10012, CAMBRC-2012-1)
  • Swansea University
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
Keywords
type 1 diabetes, artificial pancreas, artificial beta cell, sensor-augmented pump therapy, glycemic variability, HbA1c, children and adolescents, adults, continuous glucose monitoring, insulin pump therapy, free-living conditions, hypoglycemia risk reduction, glycemic control
MeSH terms
Adolescent, Adult, Algorithms, Child, Diabetes Mellitus, Type 1, Equipment Design, Female, Glycated Hemoglobin, Humans, Hypoglycemia, Hypoglycemic Agents, Insulin, Insulin Infusion Systems, Male, Middle Aged, Infusion Pumps, Implantable, Cross-Over Studies

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Home Use of an Artificial Beta Cell in Type 1 Diabetes. https://app.cochat.ai/papers/10.1056/nejmoa1509351
The paper
Thabit, H., Tauschmann, M., Allen, J. M., Leelarathna, L., Hartnell, S., Wilinska, M. E., Acerini, C. L., Dellweg, S., Benesch, C., Heinemann, L., Mader, J. K., Holzer, M., Kojzar, H., Exall, J., Yong, J., Pichierri, J., Barnard, K. D., Kollman, C., Cheng, P., . . . Hovorka, R. (2015). Home Use of an Artificial Beta Cell in Type 1 Diabetes. New England Journal of Medicine. https://doi.org/10.1056/nejmoa1509351

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.