CoChat

Clinical outcomes in real‐world patients with type 2 diabetes switching from first‐ to second‐generation basal insulin analogues: Comparative effectiveness of insulin glargine 300 units/mL and insulin degludec in the DELIVER D+ cohort study

Open access
Sullivan, Sean D., Bailey, Timothy S., Roussel, Ronan, Zhou, Fang Liz, Bosnyak, Zsolt, Preblick, Ronald, Westerbacka, Jukka, Gupta, Rishab A., Blonde, Lawrence · 2018 · Diabetes, Obesity and Metabolism
Cited by 73

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Aims: To compare clinical outcomes in patients with type 2 diabetes (T2D) switching from insulin glargine 100 units/mL (Gla‐100) or insulin detemir (IDet) to insulin glargine 300 units/mL (Gla‐300) or insulin degludec (IDeg). Materials and Methods: We conducted a retrospective, observational study of electronic medical records for Gla‐300/IDeg adult switchers (March 1, 2015 to January 31, 2017) with active records for 12‐month baseline (glycated haemoglobin [HbA1c] used a 6‐month baseline period) and 6‐month follow‐up periods. Gla‐300 and IDeg switchers were propensity score‐matched using baseline demographic and clinical characteristics. Outcomes were HbA1c change and goal attainment (among patients with HbA1c captured at follow‐up), and hypoglycaemia with fixed follow‐up (intention‐to‐treat [ITT]; 6 months) and variable follow‐up (on‐treatment [OT]; to discontinuation or 6 months). Results: Each matched cohort comprised 1592 patients. The mean decrease in HbA1c and HbA1c goal (<7.0% [53 mmol/mol] and <8.0% [64 mmol/mol]) attainment rates were similar for Gla‐300 ( n = 742) and IDeg ( n = 727) switchers. Using fixed follow‐up (ITT method), hypoglycaemia incidence decreased significantly from baseline with Gla‐300 (all hypoglycaemia: 15.6% to 12.7%; P = .006; hypoglycaemia associated with inpatient/emergency department [ED] encounter: 5.3% to 3.5%; P = .007), but not with IDeg. After adjusting for baseline hypoglycaemia, no significant differences in hypoglycaemia incidence and event rate were found at follow‐up (ITT) for Gla‐300 vs IDeg. Using variable follow‐up (OT), hypoglycaemia incidence was similar in both groups, but Gla‐300 switchers had a lower inpatient/ED hypoglycaemia event rate at follow‐up (adjusted rate ratio 0.56; P = .016). Conclusions: In a real‐world setting, switching from Gla‐100 or IDet to Gla‐300 or IDeg was associated with similar improvements in glycaemic control and hypoglycaemia in adult patients with T2D.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/dom.13345

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 73

Metadata

Authors
Sullivan, S. D., Bailey, T. S., Roussel, R., Zhou, F. L., Bosnyak, Z., Preblick, R., Westerbacka, J., Gupta, R. A., & Blonde, L.
Venue
Diabetes, Obesity and Metabolism
Publisher
Wiley
Published
2018-06-25
Volume
20
Issue
9
Pages
2148-2158
ISSN
  • 1462-8902 (ISSN-L)
  • 1463-1326
OpenAlex
W2811239016
Cited by
73
References
10
FWCI
9.04
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Clinical outcomes in real‐world patients with type 2 diabetes switching from first‐ to second‐generation basal insulin analogues: Comparative effectiveness of insulin glargine 300 units/mL and insulin degludec in the DELIVER D+ cohort study. https://app.cochat.ai/papers/10.1111/dom.13345
The paper
Sullivan, S. D., Bailey, T. S., Roussel, R., Zhou, F. L., Bosnyak, Z., Preblick, R., Westerbacka, J., Gupta, R. A., & Blonde, L. (2018). Clinical outcomes in real‐world patients with type 2 diabetes switching from first‐ to second‐generation basal insulin analogues: Comparative effectiveness of insulin glargine 300 units/mL and insulin degludec in the DELIVER D+ cohort study. Diabetes, Obesity and Metabolism. https://doi.org/10.1111/dom.13345

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.