The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
How to record high‐frequency oscillations in epilepsy: A practical guideline
Open accessAbstract
Summary: Objective: Technology for localizing epileptogenic brain regions plays a central role in surgical planning. Recent improvements in acquisition and electrode technology have revealed that high‐frequency oscillations (HFO s) within the 80–500 Hz frequency range provide the neurophysiologist with new information about the extent of the epileptogenic tissue in addition to ictal and interictal lower frequency events. Nevertheless, two decades after their discovery there remain questions about HFO s as biomarkers of epileptogenic brain and there use in clinical practice. Methods: In this review, we provide practical, technical guidance for epileptologists and clinical researchers on recording, evaluation, and interpretation of ripples, fast ripples, and very high‐frequency oscillations. Results: We emphasize the importance of low noise recording to minimize artifacts. HFO analysis, either visual or with automatic detection methods, of high fidelity recordings can still be challenging because of various artifacts including muscle, movement, and filtering. Magnetoencephalography and intracranial electroencephalography (iEEG) recordings are subject to the same artifacts. Significance: High‐frequency oscillations are promising new biomarkers in epilepsy. This review provides interested researchers and clinicians with a review of current state of the art of recording and identification and potential challenges to clinical translation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A MEMS-based flexible multichannel ECoG-electrode array
Rubehn, B., Bosman, C., Oostenveld, R., Fries, P., & Stieglitz, T. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/3/036003 · Cited by 387
Self-citation
Cited by
High‐frequency oscillations: The state of clinical research
Frauscher, B., Bartolomei, F., Kobayashi, K., Cimbalnik, J., van ‘t Klooster, M. A., Rampp, S., Otsubo, H., Höller, Y., Wu, J. Y., Asano, E., et al. (2017) · Epilepsia · doi:10.1111/epi.13829 · Cited by 395
Boehler, C., Carli, S., Fadiga, L., Stieglitz, T., & Asplund, M. (2020) · Nature Protocols · doi:10.1038/s41596-020-0389-2 · Cited by 308
Self-citationYang, H., Zhu, Z., Ni, S., Wang, X., Nie, Y., Tao, C., Zou, D., Jiang, W., Zhao, Y., Zhou, Z., et al. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116853 · Cited by 24
Fukuyama, K., & Okada, M. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23094473 · Cited by 22
Metadata
- Authors
- Zijlmans, M., Worrell, G. A., Dümpelmann, M., Stieglitz, T., Barborica, A., Heers, M., Ikeda, A., Usui, N., & Le Van Quyen, M.
- Venue
- Epilepsia
- Publisher
- Wiley
- Published
- 2017-06-16
- Volume
- 58
- Issue
- 8
- Pages
- 1305-1315
- ISSN
- 0013-9580 (ISSN-L)
- 1528-1167
- OpenAlex
- W2626794750
- Cited by
- 165
- References
- 1
- FWCI
- 14.55
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: How to record high‐frequency oscillations in epilepsy: A practical guideline. https://app.cochat.ai/papers/10.1111/epi.13814
- The paper
- Zijlmans, M., Worrell, G. A., Dümpelmann, M., Stieglitz, T., Barborica, A., Heers, M., Ikeda, A., Usui, N., & Le Van Quyen, M. (2017). How to record high‐frequency oscillations in epilepsy: A practical guideline. Epilepsia. https://doi.org/10.1111/epi.13814
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.