A MEMS-based flexible multichannel ECoG-electrode array
Open accessAbstract
We present a micromachined 252-channel ECoG (electrocorticogram)-electrode array, which is made of a thin polyimide foil substrate enclosing sputtered platinum electrode sites and conductor paths. The array subtends an area of approximately 35 mm by 60 mm and is designed to cover large parts of a hemisphere of a macaque monkey's cortex. Eight omnetics connectors are directly soldered to the foil. This leads to a compact assembly size which enables a chronic implantation of the array and allows free movements of the animal between the recording sessions. The electrode sites are 1 mm in diameter and were characterized by electrochemical impedance spectroscopy. At 1 kHz, the electrode impedances vary between 1.5 kOmega and 5 kOmega. The yield of functioning electrodes in three assembled devices is 99.5%. After implantation of a device with 100% working electrodes, standard electrocorticographic signals can be obtained from every electrode. The response to visual stimuli can be measured with electrodes lying on the visual cortex. After an implantation time of 4.5 months, all electrodes are still working and no decline in signal quality could be observed.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
For systems on flexible substrates, electrode number is usually in the order of tens for similar areas.
“For systems on flexible substrates this number is usually in the order of tens for similar areas (Rubehn et al. 2009).”
From Realizing flexible bioelectronic medicines for accessing the peripheral nerves – technology considerations (2018) · cites this paper as Rubehn et al. 2009
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Neurophysiological investigation of the basis of the fMRI signal
Logothetis, N. K., Pauls, J., Augath, M., Trinath, T., & Oeltermann, A. (2001) · Nature · doi:10.1038/35084005 · Cited by 6,542 · see citing works
The brainweb: phase synchronization and large-scale integration
Varela, F., Lachaux, J.-P., Rodriguez, E., & Martinerie, J. (2001) · Nature Reviews Neuroscience · doi:10.1038/35067550 · Cited by 4,761 · see citing works
A mechanism for cognitive dynamics: neuronal communication through neuronal coherence.
Fries, P. (2005) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2005.08.011 · Cited by 4,284 · see citing works
Self-citationDynamic predictions: Oscillations and synchrony in top–down processing
Engel, A. K., Fries, P., & Singer, W. (2001) · Nature Reviews Neuroscience · doi:10.1038/35094565 · Cited by 3,454 · see citing works
Self-citationNeuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · see citing works
Mesulam, M. (1998) · Brain · doi:10.1093/brain/121.6.1013 · Cited by 3,072 · see citing works
Electroencephalography: Basic Principles, Clinical Applications and Related Fields
Torres, F. (1983) · Archives of Neurology · doi:10.1001/archneur.1983.04050030085025 · Cited by 1,825 · see citing works
Mitzdorf, U. (1985) · Physiological Reviews · doi:10.1152/physrev.1985.65.1.37 · Cited by 1,690 · see citing works
Modulation of Neuronal Interactions Through Neuronal Synchronization
Womelsdorf, T., Schoffelen, J.-M., Oostenveld, R., Singer, W., Desimone, R., Engel, A. K., & Fries, P. (2007) · Science · doi:10.1126/science.1139597 · Cited by 1,367 · see citing works
Self-citationTemporal structure in neuronal activity during working memory in macaque parietal cortex
Pesaran, B., Pezaris, J. S., Sahani, M., Mitra, P. P., & Andersen, R. A. (2002) · Nature Neuroscience · doi:10.1038/nn890 · Cited by 1,029 · see citing works
Gamma-band synchronization in visual cortex predicts speed of change detection
Womelsdorf, T., Fries, P., Mitra, P. P., & Desimone, R. (2005) · Nature · doi:10.1038/nature04258 · Cited by 741 · see citing works
Self-citationLocal Origin of Field Potentials in Visual Cortex
Katzner, S., Nauhaus, I., Benucci, A., Bonin, V., Ringach, D. L., & Carandini, M. (2009) · Neuron · doi:10.1016/j.neuron.2008.11.016 · Cited by 552 · see citing works
Free choice activates a decision circuit between frontal and parietal cortex
Pesaran, B., Nelson, M., & Andersen, R. (2008) · Nature · doi:10.1038/nature06849 · Cited by 479 · see citing works
LFP Power Spectra in V1 Cortex: The Graded Effect of Stimulus Contrast
Henrie, J. A., & Shapley, R. M. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00919.2004 · Cited by 425 · see citing works
Sampling Properties of the Spectrum and Coherency of Sequences of Action Potentials
Jarvis, M. R., & Mitra, P. P. (2001) · Neural Computation · doi:10.1162/089976601300014312 · Cited by 392 · see citing works
Cortical Local Field Potential Encodes Movement Intentions in the Posterior Parietal Cortex
Scherberger, H., Jarvis, M. R., & Andersen, R. A. (2005) · Neuron · doi:10.1016/j.neuron.2005.03.004 · Cited by 389 · see citing works
Micromachined, Polyimide-Based Devices for Flexible Neural Interfaces
Stieglitz, T., Beutel, H., Schuettler, M., & Meyer, J.-U. (2000) · Biomedical Microdevices · doi:10.1023/a:1009955222114 · Cited by 343 · see citing works
Self-citationLocal Field Potential in Cortical Area MT: Stimulus Tuning and Behavioral Correlations
Liu, J., & Newsome, W. T. (2006) · Journal of Neuroscience · doi:10.1523/jneurosci.5052-05.2006 · Cited by 332 · see citing works
Rickert, J., de Oliveira, S. C., Vaadia, E., Aertsen, A., Rotter, S., & Mehring, C. (2005) · Journal of Neuroscience · doi:10.1523/jneurosci.0816-05.2005 · Cited by 317 · see citing works
Object Selectivity of Local Field Potentials and Spikes in the Macaque Inferior Temporal Cortex
Kreiman, G., Hung, C. P., Kraskov, A., Quiroga, R. Q., Poggio, T., & DiCarlo, J. J. (2006) · Neuron · doi:10.1016/j.neuron.2005.12.019 · Cited by 312 · see citing works
Polyimides as biomaterials: preliminary biocompatibility testing
Richardson, R. R., Miller, J. A., & Reichert, W. M. (1993) · Biomaterials · doi:10.1016/0142-9612(93)90183-3 · Cited by 302 · see citing works
Advanced Neurotechnologies for Chronic Neural Interfaces: New Horizons and Clinical Opportunities
Kipke, D. R., Shain, W. G., Buzsáki, G., Fetz, E. E., Henderson, J. M., Hetke, J. F., & Schalk, G. (2008) · Journal of Neuroscience · doi:10.1523/jneurosci.3879-08.2008 · Cited by 283 · see citing works
Lago, N., Yoshida, K., Koch, K. P., & Navarro, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886617 · Cited by 227 · see citing works
Local field potential reflects perceptual suppression in monkey visual cortex
Wilke, M., Logothetis, N. K., & Leopold, D. A. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0604673103 · Cited by 187 · see citing works
Review of signal distortion through metal microelectrode recording circuits and filters
Nelson, M. J., Pouget, P., Nilsen, E. A., Patten, C. D., & Schall, J. D. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.12.010 · Cited by 167 · see citing works
A flexible perforated microelectrode array for extended neural recordings
Boppart, S. A., Wheeler, B. C., & Wallace, C. S. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.108125 · Cited by 126 · see citing works
A MEMS fabricated flexible electrode array for recording surface field potentials
Hollenberg, B. A., Richards, C. D., Richards, R. F., Bahr, D. F., & Rector, D. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.10.016 · Cited by 96 · see citing works
Schramm, J., & Clusmann, H. (2008) · Neurosurgery · doi:10.1227/01.neu.0000316250.69898.23 · Cited by 82 · see citing works
All My Circuits: Using Multiple Electrodes to Understand Functioning Neural Networks
Miller, E. K., & Wilson, M. A. (2008) · Neuron · doi:10.1016/j.neuron.2008.10.033 · Cited by 76 · see citing works
Klinge, P. M., Vafa, M. A., Brinker, T., Brandis, A., Walter, G. F., Stieglitz, T., Samii, M., & Wewetzer, K. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00420-8 · Cited by 64 · see citing works
Self-citationCortical stimulation mapping using epidurally implanted thin-film microelectrode arrays
Molina-Luna, K., Buitrago, M. M., Hertler, B., Schubring-Giese, M., Haiss, F., Nisch, W., Schulz, J. B., & Luft, A. R. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.10.025 · Cited by 63 · see citing works
Thin-film multielectrode arrays for a cochlear prosthesis
Shamma-Donoghue, S. A., May, G. A., Cotter, N. E., et al. (1982) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1982.20671 · Cited by 56 · see citing works
Takahashi, H., Ejiri, T., Nakao, M., et al. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.809483 · Cited by 56 · see citing works
A new planar multielectrode array: recording from a rat auditory cortex
Tsytsarev, V., Taketani, M., Schottler, F., Tanaka, S., & Hara, M. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/006 · Cited by 26 · see citing works
Integrated parylene-cabled silicon probes for neural prosthetics
Huang, R., Pang, C., Tai, Y. C., Emken, J. L., Ustun, C., Andersen, R. A., & Burdick, J. W. (2008) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2008.4443637 · Cited by 23 · see citing works
Fabrication and testing of microelectrodes for small-field cortical surface recordings
Kitzmiller, J., Beversdorf, D. Q., & Hansford, D. J. (2006) · Biomedical Microdevices · doi:10.1007/s10544-006-6386-6 · Cited by 22 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
Kim, D.-H., Viventi, J., Amsden, J. J., Xiao, J., Vigeland, L., Kim, Y.-S., Blanco, J. A., Panilaitis, B., Frechette, E. S., Contreras, D., et al. (2010) · Nature Materials · doi:10.1038/nmat2745 · Cited by 1,721 · see citing works
Visual areas exert feedforward and feedback influences through distinct frequency channels
Bastos, A. M., Vezoli, J., Bosman, C. A., Schoffelen, J.-M., Oostenveld, R., Dowdall, J. R., De Weerd, P., Kennedy, H., & Fries, P. (2015) · Neuron · doi:10.1016/j.neuron.2014.12.018 · Cited by 1,320 · see citing works
Self-citationNeuroGrid: recording action potentials from the surface of the brain
Khodagholy, D., Gelinas, J. N., Thesen, T., Doyle, W., Devinsky, O., Malliaras, G. G., & Buzsáki, G. (2015) · Nature Neuroscience · doi:10.1038/nn.3905 · Cited by 938 · see citing works
Materials and technologies for soft implantable neuroprostheses
Lacour, S. P., Courtine, G., & Guck, J. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.63 · Cited by 738 · see citing works
Attentional stimulus selection through selective synchronization between monkey visual areas
Bosman, C. A., Schoffelen, J.-M., Brunet, N., Oostenveld, R., Bastos, A. M., Womelsdorf, T., Rubehn, B., Stieglitz, T., De Weerd, P., & Fries, P. (2012) · Neuron · doi:10.1016/j.neuron.2012.06.037 · Cited by 720 · see citing works
Self-citationA Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580 · see citing works
Park, D.-W., Schendel, A. A., Mikael, S., Brodnick, S. K., Richner, T. J., Ness, J. P., Hayat, M. R., Atry, F., Frye, S. T., Pashaie, R., et al. (2014) · Nature Communications · doi:10.1038/ncomms6258 · Cited by 565 · see citing works
Hassler, C., Boretius, T., & Stieglitz, T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22169 · Cited by 501 · see citing works
Self-citationMaterials for flexible bioelectronic systems as chronic neural interfaces
Song, E., Li, J., Won, S. M., Bai, W., & Rogers, J. A. (2020) · Nature Materials · doi:10.1038/s41563-020-0679-7 · Cited by 498 · see citing works
Viscoelastic surface electrode arrays to interface with viscoelastic tissues
Tringides, C. M., Vachicouras, N., de Lázaro, I., Wang, H., Trouillet, A., Seo, B. R., Elosegui-Artola, A., Fallegger, F., Shin, Y., Casiraghi, C., et al. (2021) · Nature Nanotechnology · doi:10.1038/s41565-021-00926-z · Cited by 309 · see citing works
Chiang, C.-H., Won, S. M., Orsborn, A. L., Yu, K. J., Trumpis, M., Bent, B., Wang, C., Xue, Y., Min, S., Woods, V., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aay4682 · Cited by 211 · see citing works
Top-Down Beta Enhances Bottom-Up Gamma
Richter, C. G., Thompson, W. H., Bosman, C. A., & Fries, P. (2017) · The Journal of Neuroscience · doi:10.1523/jneurosci.3771-16.2017 · Cited by 195 · see citing works
Self-citationImplantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175 · see citing works
Bastos, A. M., Litvak, V., Moran, R., Bosman, C. A., Fries, P., & Friston, K. J. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.12.081 · Cited by 152 · see citing works
Self-citationStimulus repetition modulates gamma-band synchronization in primate visual cortex
Brunet, N. M., Bosman, C. A., Vinck, M., Roberts, M., Oostenveld, R., Desimone, R., De Weerd, P., & Fries, P. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1309714111 · Cited by 130 · see citing works
Self-citationThin films and microelectrode arrays for neuroprosthetics
Ordonez, J., Schuettler, M., Boehler, C., Boretius, T., & Stieglitz, T. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.117 · Cited by 118 · see citing works
Self-citationConformable hybrid systems for implantable bioelectronic interfaces
Fallegger, F., Schiavone, G., & Lacour, S. P. (2020) · Advanced Materials · doi:10.1002/adma.201903904 · Cited by 113 · see citing works
Cortical layers, rhythms and BOLD signals
Scheeringa, R., & Fries, P. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2017.11.002 · Cited by 88 · see citing works
Self-citationHow to detect the Granger-causal flow direction in the presence of additive noise?
Vinck, M., Huurdeman, L., Bosman, C. A., Fries, P., Battaglia, F. P., Pennartz, C. M. A., & Tiesinga, P. H. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.12.017 · Cited by 77 · see citing works
Self-citationLong-term recording reliability of liquid crystal polymer <i>µ</i> ECoG arrays
Woods, V., Trumpis, M., Bent, B., Palopoli-Trojani, K., Chiang, C.-H., Wang, C., Yu, C., Insanally, M. N., Froemke, R. C., & Viventi, J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae39d · Cited by 63 · see citing works
Contrast gain control and horizontal interactions in V1: A DCM study
Pinotsis, D. A., Brunet, N., Bastos, A., Bosman, C. A., Litvak, V., Fries, P., & Friston, K. J. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.01.047 · Cited by 68 · see citing works
Self-citationČvančara, P., Boretius, T., López-Álvarez, V. M., Maciejasz, P., Andreu, D., Raspopovic, S., Petrini, F., Micera, S., Granata, G., Fernandez, E., et al. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab9a9a · Cited by 58 · see citing works
Self-citationGiagka, V., & Serdijn, W. A. (2018) · Bioelectronic Medicine · doi:10.1186/s42234-018-0010-y · Cited by 58 · see citing works
Pothof, F., Bonini, L., Lanzilotto, M., Livi, A., Fogassi, L., Orban, G. A., Paul, O., & Ruther, P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046006 · Cited by 56 · see citing works
Flexible wireless powered drug delivery system for targeted administration on cerebral cortex
Sung, S. H., Kim, Y. S., Joe, D. J., Mun, B. H., You, B. K., Keum, D. H., Hahn, S. K., Berggren, M., Kim, D., & Lee, K. J. (2018) · Nano Energy · doi:10.1016/j.nanoen.2018.06.015 · Cited by 55 · see citing works
High-density mapping of primate digit representations with a 1152-channel µECoG array
Kaiju, T., Inoue, M., Hirata, M., & Suzuki, T. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abe245 · Cited by 42 · see citing works
The Layer 7 Cortical Interface: A Scalable and Minimally Invasive Brain–Computer Interface Platform
Hettick, M., Ho, E., Poole, A. J., Monge, M., Papageorgiou, D., Takahashi, K., LaMarca, M., Trietsch, D., Reed, K., Murphy, M., et al. (2022) · doi:10.1101/2022.01.02.474656 · Cited by 31 · see citing works
Recording nerve signals in canine sciatic nerves with a flexible penetrating microelectrode array
Byun, D., Cho, S.-J., Lee, B. H., Min, J., Lee, J.-H., & Kim, S. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa7493 · Cited by 23 · see citing works
Thukral, A., Ershad, F., Enan, N., Rao, Z., & Yu, C. (2018) · IEEE Nanotechnology Magazine · doi:10.1109/mnano.2017.2781290 · Cited by 19 · see citing works
Thin-film, high-density micro-electrocorticographic decoding of a human cortical gyrus
Muller, L., Felix, S., Shah, K. G., Lee, K., Pannu, S., & Chang, E. F. (2016) · 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591001 · Cited by 15 · see citing works
Implantable Device Fabrication and Packaging
Stieglitz, T. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_102 · Cited by 7 · see citing works
Self-citationDesign and Microfabrication Considerations for Reliable Flexible Intracortical Implants
Sohal, H. S., Vassilevski, K., Jackson, A., Baker, S. N., & O’Neill, A. (2016) · Frontiers in Mechanical Engineering · doi:10.3389/fmech.2016.00005 · Cited by 4 · see citing works
- Authors
- Rubehn, B., Bosman, C., Oostenveld, R., Fries, P., & Stieglitz, T.
- Affiliations
- University of Freiburg (DE)
- Radboud University Nijmegen (NL)
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2009-05-12
- Volume
- 6
- Issue
- 3
- Pages
- 036003
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W1990283232
- Cited by
- 387
- References
- 36
- Citations by year
- 2026: 7 · 2025: 11 · 2024: 6 · 2023: 20 · 2022: 15 · 2021: 22 · 2020: 31 · 2019: 35 · 2018: 32 · 2017: 31 · 2016: 32 · 2015: 21 · 2014: 43 · 2013: 25 · 2012: 17
- FWCI
- 7.74
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- electrocorticography, flexible electrode arrays, polyimide substrate, platinum electrode, chronic implantation, electrode impedance, visual cortex responses, visual stimulation
- MeSH terms
- Animals, Brain Mapping, Cerebral Cortex, Electrodes, Implanted, Electroencephalography, Equipment Design, Macaca, Microelectrodes, Equipment Failure Analysis, Micro-Electrical-Mechanical Systems
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review