User‐based evaluation of applicability and usability of a wearable accelerometer device for detecting bilateral tonic–clonic seizures: A field study
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Summary: Clinical validation studies of seizure detection devices conducted in epilepsy monitoring units (EMUs) can be biased by the artificial environment. We report a field (phase 4) study of a wearable accelerometer device (Epi‐Care) that has previously been validated in EMUs for detecting bilateral tonic–clonic seizures (BTCS). Seventy‐one patients using the device (or their caregivers) completed the modified Post‐Study System Usability Questionnaire. Median time patients had been using the device was 15 months (range = 24 days‐6 years). In 10% of cases, patients stopped using the device due to reasons related to the device. The median sensitivity (90%) and false alarm rate (0.1/d) were similar to what had been determined in EMUs. Patients and caregivers were overall satisfied with the device (median = 5.5 on the 7‐point Likert scale), considered the technical aspects satisfactory, and considered the device comfortable and efficient. Adverse effects occurred in 11%, but were only mild: skin irritation at the wrist and interference with home electronic appliances. In 55% the device influenced the number of seizures logged into the seizure diary, and in 40% it contributed to fewer seizure‐related injuries. This field study demonstrates the applicability and usability of the wearable accelerometer device for detecting BTCS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Scheffer, I. E., Berkovic, S., Capovilla, G., Connolly, M. B., French, J., Guilhoto, L., Hirsch, E., Jain, S., Mathern, G. W., Moshé, S. L., et al. (2017) · Epilepsia · doi:10.1111/epi.13709 · Cited by 5,054
IBM computer usability satisfaction questionnaires: Psychometric evaluation and instructions for use
Lewis, J. R. (1995) · International Journal of Human-Computer Interaction · doi:10.1080/10447319509526110 · Cited by 2,429
Beniczky, S., Polster, T., Kjaer, T. W., & Hjalgrim, H. (2013) · Epilepsia · doi:10.1111/epi.12120 · Cited by 230
Self-citationNovel techniques for automated seizure registration: Patients' wants and needs
Hoppe, C., Feldmann, M., Blachut, B., Surges, R., Elger, C. E., & Helmstaedter, C. (2015) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2015.08.006 · Cited by 116
Cited by
Regalia, G., Onorati, F., Lai, M., Caborni, C., & Picard, R. W. (2019) · Epilepsy Research · doi:10.1016/j.eplepsyres.2019.02.007 · Cited by 240
Bruno, E., Böttcher, S., Viana, P. F., Amengual‐Gual, M., Joseph, B., Epitashvili, N., Dümpelmann, M., Glasstetter, M., Biondi, A., Van Laerhoven, K., et al. (2021) · Epilepsia · doi:10.1111/epi.17044 · Cited by 37
Hubbard, I., Beniczky, S., & Ryvlin, P. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.740743 · Cited by 34
Self-citationPatients self-mastery of wearable devices for seizure detection: A direct user-experience
Bruno, E., Biondi, A., Thorpe, S., & Richardson, M. P. (2020) · Seizure · doi:10.1016/j.seizure.2020.08.023 · Cited by 25
Moulaei, K., Moulaei, R., & Bahaadinbeigy, K. (2024) · DIGITAL HEALTH · doi:10.1177/20552076241237384 · Cited by 13
Metadata
- Authors
- Meritam, P., Ryvlin, P., & Beniczky, S.
- Venue
- Epilepsia
- Publisher
- Wiley
- Published
- 2018-06
- Volume
- 59
- Issue
- S1
- Pages
- 48-52
- ISSN
- 0013-9580 (ISSN-L)
- 1528-1167
- OpenAlex
- W2805436260
- Cited by
- 90
- References
- 4
- FWCI
- 6.76
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: User‐based evaluation of applicability and usability of a wearable accelerometer device for detecting bilateral tonic–clonic seizures: A field study. https://app.cochat.ai/papers/10.1111/epi.14051
- The paper
- Meritam, P., Ryvlin, P., & Beniczky, S. (2018). User‐based evaluation of applicability and usability of a wearable accelerometer device for detecting bilateral tonic–clonic seizures: A field study. Epilepsia. https://doi.org/10.1111/epi.14051
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.