Cited by 277Advanced Electron Microscopy Techniques and ApplicationsEnzyme Structure and FunctionProtein Structure and Dynamics

Cryo-electron microscopy--a primer for the non-microscopist

Open access
Milne, Jacqueline L. S., Borgnia, Mario J., Bartesaghi, Alberto, Tran, Erin E. H., Earl, Lesley A., Schauder, David M., Lengyel, Jeffrey, Pierson, Jason +2 more·2013·The FEBS Journal

Abstract

Cryo‐electron microscopy (cryo‐ EM ) is increasingly becoming a mainstream technology for studying the architecture of cells, viruses and protein assemblies at molecular resolution. Recent developments in microscope design and imaging hardware, paired with enhanced image processing and automation capabilities, are poised to further advance the effectiveness of cryo‐ EM methods. These developments promise to increase the speed and extent of automation, and to improve the resolutions that may be achieved, making this technology useful to determine a wide variety of biological structures. Additionally, established modalities for structure determination, such as X ‐ray crystallography and nuclear magnetic resonance spectroscopy, are being routinely integrated with cryo‐ EM density maps to achieve atomic‐resolution models of complex, dynamic molecular assemblies. In this review, which is directed towards readers who are not experts in cryo‐ EM methodology, we provide an overview of emerging themes in the application of this technology to investigate diverse questions in biology and medicine. We discuss the ways in which these methods are being used to study structures of macromolecular assemblies that range in size from whole cells to small proteins. Finally, we include a description of how the structural information obtained by cryo‐ EM is deposited and archived in a publicly accessible database.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/febs.12078

Cites

114 of 114 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Cryo-TEM has high resolution (0.02 Å) and easy sample preparation, and has recently emerged as a powerful tool for describing the morphology of micelles.

    “Due to the high resolution (0.02 Å) and easy sample preparation [74,164], Cryo-Transmission Electron Microscopy has recently emerged as a powerful tool for describing the morphology of micelles.”

    From Polymeric micelles in drug delivery: An insight of the techniques for their characterization and assessment in biorelevant conditions (2021) · cites this paper as [164]

    The sections on imaging and single-particle cryo-electron microscopy describe high-resolution imaging and specimen preparation by plunge-freezing. They do not support the stated resolution of 0.02 Å: the paper reports resolutions of several ångströms even for selected high-resolution structures. The cited passages do not describe cryo-TEM as a tool for micelle morphology or characterize sample preparation as easy. (LLM, conf=0.88)

    Experimental — accuracy not yet measured
  • TEM imaging requires complete sample dehydration to ensure high vacuum in the microscope column, whereas cryo-TEM is based on rapid freezing of samples at temperatures of at least -170°C using liquid nitrogen, liquid propane or liquid helium, allowing observation of specimens in their hydrated and native state and reducing artifacts related to water removal.

    “However, while TEM imaging requires complete samples dehydration in order to ensure high vacuum in the microscope column, cryo-TEM is based on the rapid freezing of samples at temperatures of at least -170 • C using liquid nitrogen, liquid propane or liquid helium [74,164], allowing for the observation of specimens in their hydrated and native state and reducing artifacts related to water removal”

    From Polymeric micelles in drug delivery: An insight of the techniques for their characterization and assessment in biorelevant conditions (2021) · cites this paper as [164]

    Split into 2 atoms — 0 confirmed, 2 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.

    Experimental — accuracy not yet measured
  • Analysis of samples at cryogenic temperatures remarkably reduces the extent of radiation damage, so imaging resolution can be easily improved by increasing the electron dose used.

    “Moreover, as the analysis of samples at cryogenic temperatures remarkably reduces the extent of radiation damage, imaging resolution can be easily improved by increasing the electron dose used [164].”

    From Polymeric micelles in drug delivery: An insight of the techniques for their characterization and assessment in biorelevant conditions (2021) · cites this paper as [164]

    In “Imaging with an electron microscope” (page unavailable), the paper says imaging at liquid-nitrogen temperatures can reduce radiation damage by as much as sixfold, permitting a much higher electron dose for the same damage. It does not say that increasing dose easily improves resolution; it also describes damage and other factors that limit high-resolution imaging. (LLM, conf=0.86)

    Experimental — accuracy not yet measured
  • AFM has also been proposed as an innovative tool for studying the mechanisms regulating nanocarrier interaction with cell membrane and their internalization.

    “AFM has also been proposed as innovative tool for studying the mechanisms regulating nanocarrier interaction with cell membrane and their internalization, which are quite relevant for ensuring effective drug delivery to the target [161][162][163].”

    From Polymeric micelles in drug delivery: An insight of the techniques for their characterization and assessment in biorelevant conditions (2021) · cites this paper as [163]

    The Abstract and the section on cryo-electron tomography discuss cryo-EM imaging of biological structures, not AFM. Searches for AFM, nanocarrier–cell membrane interactions, internalization, and drug delivery found no passage in our copy addressing the attributed proposal. Page numbers were not available. (LLM, conf=0.76)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Milne, J. L. S., Borgnia, M. J., Bartesaghi, A., Tran, E. E. H., Earl, L. A., Schauder, D. M., Lengyel, J., Pierson, J., Patwardhan, A., & Subramaniam, S.
Affiliations
  • National Institutes of Health (US)
  • Thermo Fisher Scientific (Japan) (JP)
  • European Bioinformatics Institute (GB)
Corresponding author
Subramaniam, Sriram
Venue
The FEBS Journal
Publisher
Wiley
Published
2012-12-17
Volume
280
Issue
1
Pages
28-45
ISSN
  • 1742-464X (ISSN-L)
  • 1742-4658
OpenAlex
W2047902460
Cited by
277
References
114
Citations by year
2026: 18 · 2025: 19 · 2024: 18 · 2023: 25 · 2022: 21 · 2021: 17 · 2020: 26 · 2019: 17 · 2018: 21 · 2017: 23 · 2016: 23 · 2015: 20 · 2014: 20 · 2013: 7 · 2012: 1
FWCI
2.09
Type
journal article
Language
en
Open access
Locations
  • FEBS Journal (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • National Institutes of Health
  • University of California, Los Angeles
  • Biotechnology and Biological Sciences Research Council (BB/G022577/1)
  • National Cancer Institute (ZIABC010826, ZIABC010278)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Structural Biology › Advanced Electron Microscopy Techniques and Applications
  • Physical Sciences › Materials Science › Materials Chemistry › Enzyme Structure and Function
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Protein Structure and Dynamics
Keywords
cryo-electron microscopy, macromolecular structure determination, protein assembly, virus structure, cellular architecture, cryo-EM density maps, image processing
MeSH terms
Animals, Fourier Analysis, Humans, Proteins, Cryoelectron Microscopy, Imaging, Three-Dimensional, Macromolecular Substances, Electron Microscope Tomography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review