Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 6

The DOI matches its Crossref record.

Nomogram predicting testicular torsion in Japanese patients with acute scrotal pain using physical examination findings and environmental conditions: Development and prospective external validation

Takeshita, Hideki, Tachibana, Kojiro, Sugiyama, Hironori, Kagawa, Makoto, Yano, Akihiro, Okada, Yohei, Morozumi, Makoto, Kawakami, Satoru · 2022 · International Journal of Urology

Abstract

Objectives: To develop a prediction tool based on physical findings and environmental conditions without utilizing color Doppler ultrasonography to guide non‐urologists and patients’ families in determining the testicular torsion possibility among patients with acute scrotal pain. Methods: Overall, 110 consecutive patients aged ≤30 years with acute scrotal pain at Saitama Medical Center between 2012 and 2014 were retrospectively evaluated. Physical examination results, including scrotal inspection, palpation and gait observation, and environmental conditions at pain onset (time range and ambient temperature) were collected. Multivariate analysis identified significant and independent risk factors for testicular torsion, and a nomogram predicting testicular torsion was constructed. The model underwent prospective validation in an independent set of 123 consecutive patients admitted with acute scrotal pain to our institution between 2015 and 2017. Results: Testicular torsion diagnosis rates were 27% (30/110) and 26% (32/123) in the training and validation cohorts, respectively. Logistic regression analysis showed four risk factors for developing testicular torsion: abnormal testicular position, walking difficulty, midnight to early morning onset and ambient temperature <15°C at pain onset. The constructed nomogram showed that the areas under the receiver operating characteristic curves were 0.92 and 0.84 for the training and validation cohorts, respectively. The calibration plot showed an acceptable fitness between the predicted probability and the observed rate of testicular torsion. Conclusions: A novel nomogram was developed solely based on physical findings and environmental conditions to predict testicular torsion in Japanese patients with acute scrotal pain.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/iju.14710

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 26

  1. Tekgül S, 2017, European Association of Urology Guidelines 2017, 19
  2. 10.1016/j.urology.2016.12.041 · doi:10.1016/j.urology.2016.12.041
  3. 10.1007/s00247-005-1411-0 · doi:10.1007/s00247-005-1411-0
  4. 10.1016/j.ejrad.2006.04.016 · doi:10.1016/j.ejrad.2006.04.016
  5. 10.1016/j.juro.2006.08.128 · doi:10.1016/j.juro.2006.08.128
  6. 10.1055/s-2004-821210 · doi:10.1055/s-2004-821210
  7. 10.1016/j.jpurol.2010.12.010 · doi:10.1016/j.jpurol.2010.12.010
  8. 10.1111/acem.12086 · doi:10.1111/acem.12086
  9. 10.1016/j.juro.2012.10.056 · DOI · Paper page
  10. 10.1136/bmj.285.6353.1459 · DOI
  11. 10.1016/j.juro.2007.08.049 · DOI · Paper page
  12. Hoshino H, 1993, Correlation between atmospheric temperature and testicular torsion, Hinyokika Kiyo, 39, 1031
  13. 10.1136/bmj.292.6517.363 · doi:10.1136/bmj.292.6517.363
  14. 10.1016/S0022-5347(17)42756-X · doi:10.1016/s0022-5347(17)42756-x
  15. Masuda H, 1992, Clinical study of torsion of the testis: 86 case reports, Nishinihon J. Urol., 54, 1270
  16. Takeshita H, 2016, Association between the risk of testicular torsion among acute scrotum and ambient temperature, Nihon Hinyokika Gakkai Zasshi, 107, 233
  17. 10.1111/iju.12277 · DOI
  18. Preshaw RM, 1984, Seasonal frequency of testicular torsion, Can. J. Surg., 27, 404
  19. 10.1016/S0090-4295(02)02498-6 · doi:10.1016/s0090-4295(02)02498-6
  20. 10.1002/ar.20711 · DOI
  21. 10.1038/jhh.2009.75 · DOI
  22. 10.1111/j.1365-2869.2007.00581.x · DOI · Paper page
  23. 10.1097/00004872-199412000-00014 · DOI
  24. 10.1016/j.juro.2016.01.101 · DOI
  25. 10.1016/j.juro.2013.02.013 · doi:10.1016/j.juro.2013.02.013
  26. 10.1016/S0022-3468(03)00280-X · DOI

Cited by

Metadata

Authors
Takeshita, H., Tachibana, K., Sugiyama, H., Kagawa, M., Yano, A., Okada, Y., Morozumi, M., & Kawakami, S.
Affiliations
Department of Urology Saitama Medical Center Saitama Medical University Kawagoe Saitama Japan
Venue
International Journal of Urology
Publisher
Wiley
Published
2021-10-02
Volume
29
Issue
1
Pages
42-48
ISSN
  • 0919-8172
  • 1442-2042
Cited by
6
References
0
Language
en
Funders
  • Saitama Medical University (16‐B‐1‐24)
  • Japan Society for the Promotion of Science (JP19K18597)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.