Chimney stoves modestly improved Indoor Air Quality measurements compared with traditional open fire stoves: results from a small-scale intervention study in rural Peru
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Nearly half of the world's population depends on biomass fuels to meet domestic energy needs, producing high levels of pollutants responsible for substantial morbidity and mortality. We compare carbon monoxide (CO) and particulate matter (PM2.5) exposures and kitchen concentrations in households with study-promoted intervention (OPTIMA-improved stoves and control stoves) in San Marcos Province, Cajamarca Region, Peru. We determined 48-h indoor air concentration levels of CO and PM2.5 in 93 kitchen environments and personal exposure, after OPTIMA-improved stoves had been installed for an average of 7 months. PM2.5 and CO measurements did not differ significantly between OPTIMA-improved stoves and control stoves. Although not statistically significant, a post hoc stratification of OPTIMA-improved stoves by level of performance revealed mean PM2.5 and CO levels of fully functional OPTIMA-improved stoves were 28% lower (n = 20, PM2.5, 136 μg/m(3) 95% CI 54-217) and 45% lower (n = 25, CO, 3.2 ppm, 95% CI 1.5-4.9) in the kitchen environment compared with the control stoves (n = 34, PM2.5, 189 μg/m(3), 95% CI 116-261; n = 44, CO, 5.8 ppm, 95% CI 3.3-8.2). Likewise, although not statistically significant, personal exposures for OPTIMA-improved stoves were 43% and 17% lower for PM2.5 (n = 23) and CO (n = 25), respectively. Stove maintenance and functionality level are factors worthy of consideration for future evaluations of stove interventions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lozano, R., Naghavi, M., Foreman, K., Lim, S., Shibuya, K., Aboyans, V., Abraham, J., Adair, T., Aggarwal, R., Ahn, S. Y., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61728-0 · Cited by 14,070
Smith, K. R., McCracken, J. P., Weber, M. W., Hubbard, A., Jenny, A., Thompson, L. M., Balmes, J., Diaz, A., Arana, B., & Bruce, N. (2011) · The Lancet · doi:10.1016/s0140-6736(11)60921-5 · Cited by 560 · cited 6×
“Given the large global population which experiences exposures between second-hand smoke and active tobacco smoke exposure levels, lower HAP levels must be achieved and sustained to yield greater public health benefits (Smith et al. 2011; Smith and Peel 2010).”
BackgroundInfluentialPo, J. Y. T., FitzGerald, J. M., & Carlsten, C. (2011) · Thorax · doi:10.1136/thx.2010.147884 · Cited by 450
Indoor air pollution and blood pressure in adult women living in rural China
Baumgartner, J., Schauer, J. J., Ezzati, M., Lu, L., Cheng, C., Patz, J. A., & Bautista, L. E. (2011) · Environmental Health Perspectives · doi:10.1289/ehp.1003371 · Cited by 254 · cited 2×
“…Siddiqui et al. 2008; Tielsch et al. 2009), neurodevelopment impairments (Dix-Cooper et al. 2011), cardio-vascular and other inflammatory condition (Baumgartner et al. 2011; Clark et al. 2011; McCracken et al. 2011), eye diseases, such as cataract and blindness (Smith and Mehta 2003; Saha et al.…”
BackgroundA Major Environmental Cause of Death
Martin, W. J., Glass, R. I., Balbus, J. M., & Collins, F. S. (2011) · Science · doi:10.1126/science.1213088 · Cited by 200 · cited 1×
“…carbon monoxide; particulate matter; improved chimney stoves; Peru Introduction Approximately half of the world’s population continues to depend on biomass fuels in order to meet their basic energy needs for cooking, boiling water, lighting and heating (Rehfuess et al. 2006, Martin et al. 2011).”
Background
Cited by
Towards the elimination of chronic obstructive pulmonary disease: a Lancet Commission
Stolz, D., Mkorombindo, T., Schumann, D. M., Agusti, A., Ash, S. Y., Bafadhel, M., Bai, C., Chalmers, J. D., Criner, G. J., Dharmage, S. C., et al. (2022) · The Lancet · doi:10.1016/s0140-6736(22)01273-9 · Cited by 681
Clasen, T., Checkley, W., Peel, J. L., Balakrishnan, K., McCracken, J. P., Rosa, G., Thompson, L. M., Barr, D. B., Clark, M. L., Johnson, M. A., et al. (2020) · Environmental Health Perspectives · doi:10.1289/ehp6407 · Cited by 122
“…of chimney stoves or improved solid biomass stoves have provided mixed evidence of health bene fi ts (Sambandam et al. 2015; McCracken et al. 2007; Thompson et al. 2011; Hartinger et al. 2013; Tielsch et al. 2016; Johnson et al. 2013; Mortimer et al. 2017; Lee et al. 2019; Alexander et al. 2018).”
BackgroundThomas, E., Wickramasinghe, K., Mendis, S., Roberts, N., & Foster, C. (2015) · BMC Public Health · doi:10.1186/s12889-015-2024-7 · Cited by 109
“Hartinger, 2013 [47] Chimney stoves compared to traditional open stoves Cross-sectional (within RCT) Peru 93 households (43 Ix; 48 All Both Y CO, PM2.”
BackgroundAir pollution interventions and respiratory health: a systematic review.
Saleh, S., Shepherd, W., Jewell, C., Lam, N. L., Balmes, J., Bates, M. N., Lai, P. S., Ochieng, C. A., Chinouya, M., & Mortimer, K. (2020) · The International Journal of Tuberculosis and Lung Disease · doi:10.5588/ijtld.19.0417 · Cited by 50
Metadata
- Authors
- Hartinger, S. M., Commodore, A. A., Hattendorf, J., Lanata, C. F., Gil, A. I., Verastegui, H., Aguilar-Villalobos, M., Mäusezahl, D., & Naeher, L. P.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2013-02-11
- Volume
- 23
- Issue
- 4
- Pages
- 342-352
- ISSN
- 0905-6947 (ISSN-L)
- OpenAlex
- W2126918154
- Cited by
- 56
- References
- 5
- FWCI
- 4.65
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Chimney stoves modestly improved Indoor Air Quality measurements compared with traditional open fire stoves: results from a small-scale intervention study in rural Peru. https://app.cochat.ai/papers/10.1111/ina.12027
- The paper
- Hartinger, S. M., Commodore, A. A., Hattendorf, J., Lanata, C. F., Gil, A. I., Verastegui, H., Aguilar-Villalobos, M., Mäusezahl, D., & Naeher, L. P. (2013). Chimney stoves modestly improved Indoor Air Quality measurements compared with traditional open fire stoves: results from a small-scale intervention study in rural Peru. Indoor Air. https://doi.org/10.1111/ina.12027
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.