CoChat

Indoor ozone: Concentrations and influencing factors

Nazaroff, William W, Weschler, Charles J. · 2022 · Indoor Air
Cited by 163

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Because people spend most of their time indoors, much of their exposure to ozone occurs in buildings, which are partially protective against outdoor ozone. Measurements in approximately 2000 indoor environments (residences, schools, and offices) show a central tendency for average indoor ozone concentration of 4-6 ppb and an indoor to outdoor concentration ratio of about 25%. Considerable variability in this ratio exists among buildings, as influenced by seven building-associated factors: ozone removal in mechanical ventilation systems, ozone penetration through the building envelope, air-change rates, ozone loss rate on fixed indoor surfaces, ozone loss rate on human occupants, ozone loss by homogeneous reaction with nitrogen oxides, and ozone loss by reaction with gas-phase organics. Among these, the most important are air-change rates, ozone loss rate on fixed indoor surfaces, and, in densely occupied spaces, ozone loss rate on human occupants. Although most indoor ozone originates outdoors and enters with ventilation air, indoor emission sources can materially increase indoor ozone concentrations. Mitigation technologies to reduce indoor ozone concentrations are available or are being investigated. The most mature of these technologies, activated carbon filtration of mechanical ventilation supply air, shows a high modeled health-benefit to cost ratio when applied in densely occupied spaces.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/ina.12942

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Metadata

Authors
Nazaroff, W. W., & Weschler, C. J.
Venue
Indoor Air
Publisher
Wiley
Published
2021-10-05
Volume
32
Issue
1
Pages
e12942-e12942
ISSN
  • 0905-6947 (ISSN-L)
  • 1600-0668
OpenAlex
W3204385790
Cited by
163
References
8
FWCI
8.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.