A wearable wound moisture sensor as an indicator for wound dressing change: an observational study of wound moisture and status
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Wound moisture is known to be a key parameter to ensure optimum healing conditions in wound care. This study tests the moisture content of wounds in normal practice in order to observe the moisture condition of the wound at the point of dressing change. This study is also the first large‐scale observational study that investigates wound moisture status at dressing change. The WoundSense sensor is a commercially available moisture sensor which sits directly on the wound in order to find the moisture status of the wound without disturbing or removing the dressing. The results show that of the 588 dressing changes recorded, 44·9% were made when the moisture reading was in the optimum moisture zone. Of the 30 patients recruited for this study, 11 patients had an optimum moisture reading for at least 50% of the measurements before dressing change. These results suggest that a large number of unnecessary dressing changes are being made. This is a significant finding of the study as it suggests that the protocols currently followed can be modified to allow fewer dressing changes and less disturbance of the healing wound bed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A critical review of modern and emerging absorbent dressings used to treat exuding wounds
Sweeney, I. R., Miraftab, M., & Collyer, G. (2012) · International Wound Journal · doi:10.1111/j.1742-481x.2011.00923.x · Cited by 165
Cited by
Disposable Sensors in Diagnostics, Food, and Environmental Monitoring
Dincer, C., Bruch, R., Costa‐Rama, E., Fernández‐Abedul, M. T., Merkoçi, A., Manz, A., Urban, G. A., & Güder, F. (2019) · Advanced Materials · doi:10.1002/adma.201806739 · Cited by 955
Conductive Biomaterials as Bioactive Wound Dressing for Wound Healing and Skin Tissue Engineering
Yu, R., Zhang, H., & Guo, B. (2022) · Nano-Micro Letters · doi:10.1007/s40820-021-00751-y · Cited by 880
Wound Healing: From Passive to Smart Dressings
Farahani, M., & Shafiee, A. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100477 · Cited by 794
Wearable Chemical Sensors: Present Challenges and Future Prospects
Bandodkar, A. J., Jeerapan, I., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00250 · Cited by 778
Wearables and the Medical Revolution
Dunn, J., Runge, R., & Snyder, M. (2018) · Personalized Medicine · doi:10.2217/pme-2018-0044 · Cited by 654
“Wearable oxygen diffusion sensors have been used to track wound healing, and moisture sensors can inform better timing of wound dressing changes [148,149].”
Metadata
- Authors
- Milne, S. D., Seoudi, I., Al Hamad, H., Talal, T. K., Anoop, A. A., Allahverdi, N., Zakaria, Z., Menzies, R., & Connolly, P.
- Venue
- International Wound Journal
- Publisher
- Wiley
- Published
- 2015-11-11
- Volume
- 13
- Issue
- 6
- Pages
- 1309-1314
- ISSN
- 1742-4801 (ISSN-L)
- 1742-481X
- OpenAlex
- W2167180770
- Cited by
- 141
- References
- 1
- FWCI
- 4.63
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.