Time‐frequency balanced spectral entropy as a measure of anesthetic drug effect in central nervous system during sevoflurane, propofol, and thiopental anesthesia
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Background: Time‐frequency balanced spectral entropy of electroencephalogram (EEG) and frontal electromyogram (FEMG) is a novel measure of hypnosis during anesthesia. Two Entropy parameters are described: Response entropy (RE) is calculated from EEG and FEMG; and State Entropy (SE) is calculated mainly from EEG. This study was performed to validate their performance during transition from consciousness to unconsciousness under different anesthetic agents. Methods: Response entropy, SE [S/5™ Entropy Module, M‐ENTROPY (later in text: Entropy), Datex‐Ohmeda Division, Instrumentarium Corp., Helsinki, Finland] and BIS (BIS XP, A‐2000, Aspect Medical Systems, Newton, MA) data were collected from 70 patients; 30 anesthetized with propofol 2 mg kg−1, 20 with sevoflurane inhalation, and 20 with thiopental 5 mg kg−1. Loss and regaining of consciousness (LOC, ROC) was tested every 10 s, and sensitivity, specificity, and prediction probability (Pk) were calculated. Behavior of the indices was studied. Results: Sensitivity, specificity, and Pk values for consciousness were high and similar for all indices. During regaining of consciousness after propofol bolus, RE, SE, and BIS values recovered by 81 ± 22%, 75 ± 26%, and 59 ± 18% (mean ± SD), respectively, from the minimum relative to their baseline. After thiopental bolus, RE, SE, and BIS values recovered by 86±21%, 88 ± 13%, and 63 ± 14%, respectively. The relative rise was higher in RE and SE compared with BIS (P < 0.01). During deep levels of hypnosis, RE and SE decreased monotonously as a function of burst suppression ratio, while BIS showed biphasic behavior. On average, RE indicated emergence from anesthesia 11 s earlier than SE, and 12.4 s earlier than BIS. Conclusions: All indices, RE, SE, and BIS, distinguished excellently between conscious and unconscious states during propofol, sevoflurane, and thiopental anesthesia. During burst suppression, Entropy parameters RE and SE, but not BIS, behave monotonously. During regaining of consciousness after a thiopental or propofol bolus, RE and SE values recovered significantly closer to their baseline values than did BIS. Response entropy indicates emergence from anesthesia earlier than SE or BIS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Mathematical Theory of Communication
Shannon, C. E. (1948) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1948.tb01338.x · Cited by 88,486
A Mathematical Theory of Communication
Shannon, C. E. (1948) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1948.tb00917.x · Cited by 48,949
A Primer for EEG Signal Processing in Anesthesia
Rampil, I. J. (1998) · Anesthesiology · doi:10.1097/00000542-199810000-00023 · Cited by 1,503
A regularity statistic for medical data analysis
Pincus, S. M., Gladstone, I. M., & Ehrenkranz, R. A. (1991) · Journal of Clinical Monitoring · doi:10.1007/bf01619355 · Cited by 788
Gan, T. J., Glass, P. S. A., Windsor, A. C. J., Payne, F. C., Rosow, C. E., Sebel, P. S., & Manberg, P. J. (1997) · Anesthesiology · doi:10.1097/00000542-199710000-00014 · Cited by 691
Description of the Entropy™ algorithm as applied in the Datex‐Ohmeda S/5™ Entropy Module
Viertiö‐Oja, H., Maja, V., Särkelä, M., Talja, P., Tenkanen, N., Tolvanen‐Laakso, H., Paloheimo, M., Vakkuri, A., Yli‐Hankala, A., & Meriläinen, P. (2004) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.0001-5172.2004.00322.x · Cited by 582
Self-citationMeasuring the Performance of Anesthetic Depth Indicators
Smith, W. D., Dutton, R. C., & Smith, T. N. (1996) · Anesthesiology · doi:10.1097/00000542-199601000-00005 · Cited by 418
Quantification of EEG irregularity by use of the entropy of the power spectrum
Inouye, T., Shinosaki, K., Sakamoto, H., Toi, S., Ukai, S., Iyama, A., Katsuda, Y., & Hirano, M. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90138-t · Cited by 404
Bruhn, J., Röpcke, H., & Hoeft, A. (2000) · Anesthesiology · doi:10.1097/00000542-200003000-00016 · Cited by 368
Stochastic complexity measures for physiological signal analysis
Rezek, I. A., & Roberts, S. J. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.709563 · Cited by 288
Drover, D. R., Lemmens, H. J., Pierce, E. T., Plourde, G., Loyd, G., Ornstein, E., Prichep, L. S., Chabot, R. J., & Gugino, L. (2002) · Anesthesiology · doi:10.1097/00000542-200207000-00012 · Cited by 173
Changes in electromyogram power spectra of facial and jaw-elevator muscles during fatigue
Boxtel, A. V., Goudswaard, P., van der Molen, G. M., & Bosch, W. E. J. V. D. (1983) · Journal of Applied Physiology · doi:10.1152/jappl.1983.54.1.51 · Cited by 104
Which is the better entropy expression for speech processing: -S log S or log S?
Johnson, R., & Shore, J. E. (1984) · IEEE Transactions on Acoustics Speech and Signal Processing · doi:10.1109/tassp.1984.1164296 · Cited by 102
Different benefit of bispectal index (BIS™) in desflurane and propofol anesthesia
Luginbühl, M., Wüthrich, S., Petersen‐Felix, S., Zbinden, A. M., & Schnider, T. W. (2003) · Acta Anaesthesiologica Scandinavica · doi:10.1034/j.1399-6576.2003.00041.x · Cited by 96
Assessment of anaesthetic adequacy with upper facial and abdominal wall EMG.
Paloheimo, M., Hl, E., Wirtavuori, K., & Tammisto, T. (1989) · PubMed · Cited by 40
Comparison of neuromuscular blockade in upper facial and hypothenar muscles
Paloheimo, M., Wilson, R. C., Edmonds, H. L., Lucas, L. F., & Triantafillou, A. N. (1988) · Journal of Clinical Monitoring and Computing · doi:10.1007/bf01617322 · Cited by 27
Cited by
Permutation entropy of the electroencephalogram: a measure of anaesthetic drug effect
Olofsen, E., Sleigh, J. W., & Dahan, A. (2008) · British Journal of Anaesthesia · doi:10.1093/bja/aen290 · Cited by 358
Depth of anaesthesia monitoring: what’s available, what’s validated and what’s next?
Bruhn, J., Myles, P. S., Sneyd, R., & Struys, M. M. R. F. (2006) · British Journal of Anaesthesia · doi:10.1093/bja/ael120 · Cited by 341
Electroencephalogram spindle activity during dexmedetomidine sedation and physiological sleep
HUUPPONEN, E., MAKSIMOW, A., LAPINLAMPI, P., SÄRKELÄ, M., SAASTAMOINEN, A., SNAPIR, A., SCHEININ, H., SCHEININ, M., MERILÄINEN, P., HIMANEN, S., et al. (2008) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2007.01537.x · Cited by 323
Assessment of surgical stress during general anaesthesia
Huiku, M., Uutela, K., van Gils, M., Korhonen, I., Kymäläinen, M., Meriläinen, P., Paloheimo, M., Rantanen, M., Takala, P., Viertiö-Oja, H., et al. (2007) · British Journal of Anaesthesia · doi:10.1093/bja/aem004 · Cited by 317
Self-citationHans, P., Dewandre, P.-Y., Brichant, J. F., & Bonhomme, V. (2005) · British Journal of Anaesthesia · doi:10.1093/bja/aei047 · Cited by 271
Metadata
- Authors
- Vakkuri, A., Yli‐Hankala, A., Talja, P., Mustola, S., Tolvanen‐Laakso, H., Sampson, T., & Viertiö‐Oja, H.
- Venue
- Acta Anaesthesiologica Scandinavica
- Publisher
- Wiley
- Published
- 2004-01-22
- Volume
- 48
- Issue
- 2
- Pages
- 145-153
- ISSN
- 0001-5172 (ISSN-L)
- 1399-6576
- OpenAlex
- W1986966459
- Cited by
- 293
- References
- 16
- FWCI
- 26.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.