The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Measuring the Performance of Anesthetic Depth Indicators
Abstract
Background: An appropriate measure of performance is needed to identify anesthetic depth indicators that are promising for use in clinical monitoring. To avoid misleading results, the measure must take into account both desired indicator performance and the nature of available performance data. Ideally, anesthetic depth indicator value should correlate perfectly with anesthetic depth along a lighter-deeper anesthesia continuum. Experimentally, however, a candidate anesthetic depth indicator is judged against a "gold standard" indicator that provides only quantal observations of anesthetic depth. The standard anesthetic depth indicator is the patient's response to a specified stimulus. The resulting observed anesthetic depth scale may consist only of patient "response" versus "no response," or it may have multiple levels. The measurement scales for both the candidate anesthetic depth indicator and observed anesthetic depth are no more than ordinal; that is, only the relative rankings of values on these scales are meaningful. Methods: Criteria were established for a measure of anesthetic depth indicator performance and the performance measure that best met these criteria was found. Results: The performance measure recommended by the authors is prediction probability PK, a rescaled variant of Kim's dy.x measure of association. This performance measure shows the correlation between anesthetic depth indicator value and observed anesthetic depth, taking into account both desired performance and the limitations of the data. Prediction probability has a value of 1 when the indicator predicts observed anesthetic depth perfectly, and a value of 0.5 when the indicator predicts no better than a 50:50 chance. Prediction probability avoids the shortcomings of other measures. For example, as a nonparametric measure, PK is independent of scale units and does not require knowledge of underlying distributions or efforts to linearize or to otherwise transform scales. Furthermore, PK can be computed for any degree of coarseness or fineness of the scales for anesthetic depth indicator value and observed anesthetic depth; thus, PK fully uses the available data without imposing additional arbitrary constraints, such as the dichotomization of either scale. And finally, PK can be used to perform both grouped- and paired-data statistical comparisons of anesthetic depth indicator performance. Data for comparing depth indicators, however, must be gathered via the same response-to-stimulus test procedure and over the same distribution of anesthetic depths. Conclusions: Prediction probability PK is an appropriate measure for evaluating and comparing the performance of anesthetic depth indicators.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonparametric Statistics for the Behavioral Sciences
Guitton, H., & Siegel, S. (1958) · Revue économique · doi:10.2307/3498751 · Cited by 35,245
A Simple Sequentially Rejective Multiple Test Procedure
(1979) · Scandinavian Journal of Statistics · doi:10.2307/4615733 · Cited by 21,526
Bootstrap methods: another look at the jackknife
Efron, B. (1979) · The Annals of Statistics · doi:10.1214/aos/1176344552 · Cited by 17,602
Measures of Association for Cross Classifications
Goodman, L. A., & Kruskal, W. H. (1979) · Springer Series in Statistics · doi:10.1007/978-1-4612-9995-0 · Cited by 2,244
MILLER, R. G. (1974) · Biometrika · doi:10.1093/biomet/61.1.1 · Cited by 1,467
Bamber, D. (1975) · Journal of Mathematical Psychology · doi:10.1016/0022-2496(75)90001-2 · Cited by 1,439
Probit Analysis: A Statistical Treatment of the Sigmoid Response Curve.
I., J. O., Finney, D. J., & Tattersfield, F. (1947) · Journal of the Royal Statistical Society · doi:10.2307/2981407 · Cited by 1,239
Minimum Alveolar Anesthetic Concentration: A Standard of Anesthetic Potency
Eger, E. I., Saidman, L. J., & Brandstater, B. (1965) · Anesthesiology · doi:10.1097/00000542-196511000-00010 · Cited by 853
Receiver operating characteristic (ROC) methodology: the state of the art.
Hanley, J. A. (1989) · PubMed · Cited by 685
A New Asymmetric Measure of Association for Ordinal Variables
Somers, R. H. (1962) · American Sociological Review · doi:10.2307/2090408 · Cited by 671
Cited by
Glass, P. S., Bloom, M., Kearse, L., Rosow, C., Sebel, P., & Manberg, P. (1997) · Anesthesiology · doi:10.1097/00000542-199704000-00014 · Cited by 1,274
Development and Clinical Application of Electroencephalographic Bispectrum Monitoring
Johansen, J. W., Sebel, P. S., & Fisher, D. M. (2000) · Anesthesiology · doi:10.1097/00000542-200011000-00029 · Cited by 599
Depth of anaesthesia monitoring: what’s available, what’s validated and what’s next?
Bruhn, J., Myles, P. S., Sneyd, R., & Struys, M. M. R. F. (2006) · British Journal of Anaesthesia · doi:10.1093/bja/ael120 · Cited by 341
Katoh, T., Suzuki, A., & Ikeda, K. (1998) · Anesthesiology · doi:10.1097/00000542-199803000-00014 · Cited by 333
Theories and measures of consciousness: An extended framework
Seth, A. K., Izhikevich, E., Reeke, G. N., & Edelman, G. M. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0604347103 · Cited by 321
Metadata
- Authors
- Smith, W. D., Dutton, R. C., & Smith, T. N.
- Venue
- Anesthesiology
- Published
- 1996-01-01
- Volume
- 84
- Issue
- 1
- Pages
- 38-51
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2112101180
- Cited by
- 418
- References
- 29
- FWCI
- 9.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measuring the Performance of Anesthetic Depth Indicators. https://app.cochat.ai/papers/10.1097/00000542-199601000-00005
- The paper
- Smith, W. D., Dutton, R. C., & Smith, T. N. (1996). Measuring the Performance of Anesthetic Depth Indicators. Anesthesiology. https://doi.org/10.1097/00000542-199601000-00005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.