Meta‐analysis of Diagnostic Test Accuracy Assessment Studies with Varying Number of Thresholds
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Summary. Current meta‐analytic methods for diagnostic test accuracy are generally applicable to a selection of studies reporting only estimates of sensitivity and specificity, or at most, to studies whose results are reported using an equal number of ordered categories. In this article, we propose a new meta‐analytic method to evaluate test accuracy and arrive at a summary receiver operating characteristic (ROC) curve for a collection of studies evaluating diagnostic tests, even when test results are reported in an unequal number of nonnested ordered categories. We discuss both non‐Bayesian and Bayesian formulations of the approach. In the Bayesian setting, we propose several ways to construct summary ROC curves and their credible bands. We illustrate our approach with data from a recently published meta‐analysis evaluating a single serum progesterone test for diagnosing pregnancy failure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Regression Models for Ordinal Data
McCullagh, P. (1980) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1980.tb01109.x · Cited by 4,453 · cited 1×
“A smooth ROC curve can be estimated via parametric methods (McCullagh, 1980; Tosteson and Begg, 1988; Pepe, 2000) or semi- and nonparametric methods (Zou, Hall, and Shapiro, 1997; Pepe, 2000).”
MethodTowards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
Self-citationTowards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Self-citationTowards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Self-citationEmpirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 1×
“However, recent reviews of studies of diagnostic tests have discussed the influence of study design on diagnostic performance in greater detail (Lijmer et al., 1999; Bossuyt et al., 2003).”
BackgroundMeta-analysis of screening and diagnostic tests.
Hasselblad, V., & Hedges, L. V. (1995) · Psychological Bulletin · doi:10.1037/0033-2909.117.1.167 · Cited by 579 · cited 2×
“…to combine information from such studies in both fixed and random-effect frameworks (Moses, Shapiro, and Littenberg, 1993; Irwig et al., 1994; Hasselblad and Hodges, 1995; Irwig et al., 1995; Shapiro, 1995; Rutter and Gatsonis, 1995, 2001; Hellmich, Abrams, and Sutton, 1999; Kester and…”
BackgroundMethod
Cited by
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationCochrane Handbook for Systematic Reviews of Diagnostic Test Accuracy
(2023) · doi:10.1002/9781119756194 · Cited by 757
A unification of models for meta-analysis of diagnostic accuracy studies
Harbord, R. M., Deeks, J. J., Egger, M., Whiting, P., & Sterne, J. A. C. (2007) · Biostatistics · doi:10.1093/biostatistics/kxl004 · Cited by 751
Recent developments in meta‐analysis
Sutton, A. J., & Higgins, J. P. T. (2008) · Statistics in Medicine · doi:10.1002/sim.2934 · Cited by 590
Shaheen, A. A. M., & Myers, R. P. (2007) · Hepatology · doi:10.1002/hep.21835 · Cited by 397
Metadata
- Authors
- Dukic, V., & Gatsonis, C.
- Venue
- Biometrics
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-12
- Volume
- 59
- Issue
- 4
- Pages
- 936-946
- ISSN
- 0006-341X (ISSN-L)
- 1541-0420
- OpenAlex
- W2007276811
- Cited by
- 101
- References
- 6
- FWCI
- 2.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Meta‐analysis of Diagnostic Test Accuracy Assessment Studies with Varying Number of Thresholds. https://app.cochat.ai/papers/10.1111/j.0006-341x.2003.00108.x
- The paper
- Dukic, V., & Gatsonis, C. (2003). Meta‐analysis of Diagnostic Test Accuracy Assessment Studies with Varying Number of Thresholds. Biometrics. https://doi.org/10.1111/j.0006-341x.2003.00108.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.