The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Detection of Epileptiform Activity by Human Interpreters: Blinded Comparison between Electroencephalography and Magnetoencephalography
Open accessAbstract
Summary: Purpose: Objectively to evaluate whether independent spike detection by human interpreters is clinically valid in magnetoencephalography (MEG) and to characterize detection differences between MEG and scalp electroencephalography (EEG). Methods: We simultaneously recorded scalp EEG and MEG data from 43 patients with intractable focal epilepsy. Raw EEG and MEG waveforms were reviewed independently by two experienced epileptologists, one for EEG and one for MEG, blinded to the other modality and to the clinical information. The number and localization of spikes detected by EEG and/or MEG were compared in relation to clinical diagnosis based on postoperative seizure freedom. Results: Interictal spikes were captured in both EEG and MEG in 31, in MEG alone in eight, in EEG alone in one, and in neither modality in three patients. The number of detections ranged widely with no statistical difference between modalities. A median of 25.7% of total spikes was detectable by both modalities. Spike localization was similarly consistent with the epilepsy diagnosis in 85.2% (EEG) and 78.1% (MEG) of the patients. Inaccurate localization occurred only in those cases with very few spikes detected, especially when the detections were in one modality alone. Conclusions: Interictal epileptiform discharges are easily perceived in MEG. Independent spike identification in MEG can provide clinical results comparable, but not superior, to EEG. Many spikes were seen in only one modality or the other; therefore the use of both EEG and MEG may provide additional information.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Cited by
A guideline for head volume conductor modeling in EEG and MEG
Vorwerk, J., Cho, J.-H., Rampp, S., Hamer, H., Knösche, T. R., & Wolters, C. H. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.06.040 · Cited by 302
Goldenholz, D. M., Ahlfors, S. P., Hämäläinen, M. S., Sharon, D., Ishitobi, M., Vaina, L. M., & Stufflebeam, S. M. (2009) · Human Brain Mapping · doi:10.1002/hbm.20571 · Cited by 266
Metadata
- Authors
- Iwasaki, M., Pestana, E., Burgess, R. C., Lüders, H. O., Shamoto, H., & Nakasato, N.
- Venue
- Epilepsia
- Publisher
- Wiley
- Published
- 2005-01
- Volume
- 46
- Issue
- 1
- Pages
- 59-68
- ISSN
- 0013-9580 (ISSN-L)
- 1528-1167
- OpenAlex
- W2033512109
- Cited by
- 160
- References
- 1
- FWCI
- 5.32
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of Epileptiform Activity by Human Interpreters: Blinded Comparison between Electroencephalography and Magnetoencephalography. https://app.cochat.ai/papers/10.1111/j.0013-9580.2005.21104.x
- The paper
- Iwasaki, M., Pestana, E., Burgess, R. C., Lüders, H. O., Shamoto, H., & Nakasato, N. (2005). Detection of Epileptiform Activity by Human Interpreters: Blinded Comparison between Electroencephalography and Magnetoencephalography. Epilepsia. https://doi.org/10.1111/j.0013-9580.2005.21104.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.