Detection of Epileptiform Activity by Human Interpreters: Blinded Comparison between Electroencephalography and Magnetoencephalography
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Summary: Purpose: Objectively to evaluate whether independent spike detection by human interpreters is clinically valid in magnetoencephalography (MEG) and to characterize detection differences between MEG and scalp electroencephalography (EEG). Methods: We simultaneously recorded scalp EEG and MEG data from 43 patients with intractable focal epilepsy. Raw EEG and MEG waveforms were reviewed independently by two experienced epileptologists, one for EEG and one for MEG, blinded to the other modality and to the clinical information. The number and localization of spikes detected by EEG and/or MEG were compared in relation to clinical diagnosis based on postoperative seizure freedom. Results: Interictal spikes were captured in both EEG and MEG in 31, in MEG alone in eight, in EEG alone in one, and in neither modality in three patients. The number of detections ranged widely with no statistical difference between modalities. A median of 25.7% of total spikes was detectable by both modalities. Spike localization was similarly consistent with the epilepsy diagnosis in 85.2% (EEG) and 78.1% (MEG) of the patients. Inaccurate localization occurred only in those cases with very few spikes detected, especially when the detections were in one modality alone. Conclusions: Interictal epileptiform discharges are easily perceived in MEG. Independent spike identification in MEG can provide clinical results comparable, but not superior, to EEG. Many spikes were seen in only one modality or the other; therefore the use of both EEG and MEG may provide additional information.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Surgical Treatment of the Epilepsies
Kotagal, P. (1994) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199407000-00009 · Cited by 2,747
Outcome with respect to epileptic seizures.
Engel, J. (1993) · Medical Entomology and Zoology · Cited by 2,338
Linear and Nonlinear Current Density Reconstructions
Fuchs, M., Wagner, M., Köhler, T., & Wischmann, H.-A. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199905000-00006 · Cited by 436
A Quantitative Assessment of the Sensitivity of Whole-Head MEG to Activity in the Adult Human Cortex
Hillebrand, A., & Barnes, G. R. (2002) · NeuroImage · doi:10.1006/nimg.2002.1102 · Cited by 428 · cited 1×
“The cortical areas that contribute to surface EEG and MEG activities largely overlap each other (36).”
BackgroundRecursive MUSIC: A framework for EEG and MEG source localization
Mosher, J. C., & Leahy, R. M. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.725331 · Cited by 362
Magnetic brain source imaging of focal epileptic activity: a synopsis of 455 cases
Stefan, H. (2003) · Brain · doi:10.1093/brain/awg239 · Cited by 304
Demonstration of useful differences between magnetoencephalogram and electroencephalogram
Cohen, D., & Cuffin, B. N. (1983) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(83)90005-6 · Cited by 300
Characterization of spontaneous MEG rhythms in healthy adults
Salmelin, R., & Hari, R. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90187-2 · Cited by 280 · cited 1×
“MEG has a different vulnerability to external noise (29) and has sensitivity to some uncommon background brain noise (30,31).”
BackgroundA Comparison of Magnetoencephalography, MRI, and V‐EEG in Patients Evaluated for Epilepsy Surgery
Wheless, J. W., Willmore, L. J., Breier, J. I., Kataki, M., Smith, J. R., King, D. W., Meador, K. J., Park, Y. D., Loring, D. W., Clifton, G. L., et al. (1999) · Epilepsia · doi:10.1111/j.1528-1157.1999.tb00800.x · Cited by 193
Recommendations for the practice of clinical neurophysiology
Meyjes, F. E. P., & Arts, R. J. H. M. (1984) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(84)90023-6 · Cited by 179 · cited 1×
“Epileptic spikes or sharp waves were manually detected by applying the same general principles recommended by the International Federation of Clinical Neurophysiology (IFCN) and used in standard EEG interpretation: sharp transient clearly different from background activity with an “epileptiform” morphology and a logic…”
Defining Epileptogenic Foci: Past, Present, Future
Ebersole, J. S. (1997) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199711000-00003 · Cited by 173 · cited 1×
“In actual practice, however, we encounter a broad range of orientations, with the real generator extending over the cortical surface, including both gyral wall and lateral surface (7).”
BackgroundMagnetoencephalographic 10-Hz rhythm from the human auditory cortex
Tiihonen, J., Hari, R., Kajola, M., Karhu, J., Ahlfors, S. P., & Tissari, S. O. (1991) · Neuroscience Letters · doi:10.1016/0304-3940(91)90486-d · Cited by 165 · cited 1×
“MEG has a different vulnerability to external noise (29) and has sensitivity to some uncommon background brain noise (30,31).”
BackgroundMEG Predicts Epileptic Zone in Lesional Extrahippocampal Epilepsy: 12 Pediatric Surgery Cases
Otsubo, H., Ochi, A., Elliott, I., Chuang, S. H., Rutka, J. T., Jay, V., Aung, M., Sobel, D. F., & Snead, O. C. (2001) · Epilepsia · doi:10.1046/j.1528-1157.2001.16701.x · Cited by 161
Sensitivity distributions of EEG and MEG measurements
Malmivuo, J. A., Suihko, V., & Eskola, H. J. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554766 · Cited by 150 · cited 1×
“(35) shows, the size and distribution of the volume that a planar gradiometer is sensitive to is comparable to that of scalp EEG recorded from a pair of neighboring electrodes in the standard 10– 20 placement.”
ResultNeuromagnetic Recordings in Temporal Lobe Epilepsy
Baumgartner, C., Pataraia, E., Lindinger, G., & Deecke, L. (2000) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200003000-00007 · Cited by 130 · cited 1×
“MEG that were not captured with scalp EEG (6,15,19,20).”
BackgroundMagnetoencephalography-directed surgery in patients with neocortical epilepsy
Mamelak, A. N., López, N., Akhtari, M., et al. (2002) · Journal of neurosurgery · doi:10.3171/jns.2002.97.4.0865 · Cited by 114
Surgical Implications of Neuromagnetic Spike Localization in Temporal Lobe Epilepsy
Iwasaki, M., Nakasato, N., Shamoto, H., Nagamatsu, K., Kanno, A., Hatanaka, K., & Yoshimoto, T. (2002) · Epilepsia · doi:10.1046/j.1528-1157.2002.30801.x · Cited by 109
Self-citationIctal magnetic source imaging as a localizing tool in partial epilepsy
Eliashiv, D. S., Elsas, S., Squires, K. C., Fried, I., & Engel, J. (2002) · Neurology · doi:10.1212/01.wnl.0000032493.83875.0b · Cited by 105
Malignant rolandic-sylvian epilepsy in children: Diagnosis, treatment, and outcomes
Otsubo, H., Chitoku, S., Ochi, A., Jay, V., Rutka, J. T., Smith, M.-L., Elliott, I., & Snead, O. C. (2001) · Neurology · doi:10.1212/wnl.57.4.590 · Cited by 89
Atlas and classification of electroencephalography
Torres, F. (2000) · Pediatric Neurology · doi:10.1016/s0887-8994(00)00118-1 · Cited by 89 · cited 2×
“Epileptic spikes or sharp waves were manually detected by using conventional visual identification, as is done during routine EEG interpretation (23).”
MethodMagnetoencephalography in presurgical epilepsy evaluation
Pataraia, E., Baumgartner, C., Lindinger, G., & Deecke, L. (2002) · Neurosurgical Review · doi:10.1007/s10143-001-0197-2 · Cited by 80
Leijten, F. S. S., Huiskamp, G. J. M., Hilgersom, I., & van Huffelen, A. C. (2003) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200307000-00001 · Cited by 79
Magnetoencephalographic yield of interictal spikes in temporal lobe epilepsy
Lin, Y., Shih, Y., Hsieh, J., Yu, H., Yiu, C. H., Wong, T., Yeh, T., Kwan, S.-Y., Ho, L. ‐., Yen, D., et al. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00181-2 · Cited by 76 · cited 1×
“(32) classified interictal spikes during simultaneous EEG and MEG recording similar to our study.”
ResultInterictal and Ictal Magnetoencephalographic Study in Patients with Medial Frontal Lobe Epilepsy
Shiraishi, H., Watanabe, Y., Watanabe, M., Inoue, Y., Fujiwara, T., & Yagi, K. (2001) · Epilepsia · doi:10.1046/j.1528-1157.2001.042007875.x · Cited by 73
Benefit of Simultaneous Recording of EEG and MEG in Dipole Localization
Yoshinaga, H., Nakahori, T., Ohtsuka, Y., Oka, E., Kitamura, Y., Kiriyama, H., Kinugasa, K., Miyamoto, K., & Hoshida, T. (2002) · Epilepsia · doi:10.1046/j.1528-1157.2002.42901.x · Cited by 65 · cited 1×
“MEG that were not captured with scalp EEG (6,15,19,20).”
BackgroundAtlas and Classification of Electroencephalography
Lüders, H. O., & Noachtar, S. (2000) · Medical Entomology and Zoology · Cited by 65
Zijlmans, M., Huiskamp, G. J. M., Leijten, F. S. S., der Meij, W. V., Wieneke, G. H., & van Huffelen, A. C. (2002) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200206000-00001 · Cited by 60 · cited 2×
“It also is likely that interinterpreter inconsistency is more frequent for MEG than for EEG because only limited experience is found with visual MEG spike identification (5).”
BackgroundCardiac Artifacts in Magnetoencephalogram
Jousm??ki, V., & Hari, R. (1996) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199603000-00008 · Cited by 59 · cited 1×
“MEG has a different vulnerability to external noise (29) and has sensitivity to some uncommon background brain noise (30,31).”
BackgroundEnt, D. V. ‘., Manshanden, I., Ossenblok, P., Velis, D. N., de Munck, J. C., Verbunt, J. P. A., & Lopes, F. H. D. S. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00156-1 · Cited by 57
Focal magnetoencephalographic spikes in the superior temporal plane undetected by scalp EEG
Iwasaki, M., Nakasato, N., Shamoto, H., & Yoshimoto, T. (2003) · Journal of Clinical Neuroscience · doi:10.1016/s0967-5868(02)00342-9 · Cited by 19 · cited 1×
“MEG that were not captured with scalp EEG (6,15,19,20).”
BackgroundSelf-citationLesser, R. P. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2003.12.012 · Cited by 17 · cited 2×
“Use of information from both modalities may increase the sensitivity and specificity to spikes (18).”
Background
Cited by
A guideline for head volume conductor modeling in EEG and MEG
Vorwerk, J., Cho, J.-H., Rampp, S., Hamer, H., Knösche, T. R., & Wolters, C. H. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.06.040 · Cited by 302
Goldenholz, D. M., Ahlfors, S. P., Hämäläinen, M. S., Sharon, D., Ishitobi, M., Vaina, L. M., & Stufflebeam, S. M. (2009) · Human Brain Mapping · doi:10.1002/hbm.20571 · Cited by 266
IFCN-endorsed practical guidelines for clinical magnetoencephalography (MEG)
Hari, R., Baillet, S., Barnes, G., Burgess, R., Forss, N., Gross, J., Hämäläinen, M., Jensen, O., Kakigi, R., Mauguière, F., et al. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.03.042 · Cited by 167
“The yield of epileptic spikes has been much higher in MEG than in scalp EEG recordings (Iwasaki et al., 2005; Kakisaka et al., 2012), leading to a better sampling and localization of the epileptogenic”
BackgroundMethodSelf-citation
Metadata
- Authors
- Iwasaki, M., Pestana, E., Burgess, R. C., Lüders, H. O., Shamoto, H., & Nakasato, N.
- Venue
- Epilepsia
- Publisher
- Wiley
- Published
- 2005-01
- Volume
- 46
- Issue
- 1
- Pages
- 59-68
- ISSN
- 0013-9580 (ISSN-L)
- 1528-1167
- OpenAlex
- W2033512109
- Cited by
- 160
- References
- 32
- FWCI
- 5.32
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.