Evaluation of spectral imaging for plant cell analysis
The DOI matches its Crossref record.
Abstract
Summary: Fluorescence imaging at high spectral resolution is now a practical reality and has great promise in plant cell biology. Emission spectral curve data can be used computationally to distinguish spectrally similar fluorophores, or to remove autofluorescence, and to spectrally analyse autofluorescent molecules, which are especially abundant in plant tissues. Examples of these applications in plant cells are given, and a comparison is made between the current offerings in spectral imaging laser scanning confocal microscopes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Heisler, M. G., Ohno, C., Das, P., Sieber, P., Reddy, G. V., Long, J. A., & Meyerowitz, E. M. (2005) · Current Biology · doi:10.1016/j.cub.2005.09.052 · Cited by 1,189
Cell and tissue autofluorescence research and diagnostic applications
Monici, M. (2005) · Biotechnology Annual Review · doi:10.1016/s1387-2656(05)11007-2 · Cited by 887
Donaldson, L. (2020) · Molecules · doi:10.3390/molecules25102393 · Cited by 413
Two-photon fluorescence excitation and related techniques in biological microscopy
Diaspro, A., Chirico, G., & Collini, M. (2005) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583505004129 · Cited by 318
Snapshot Image Mapping Spectrometer (IMS) with high sampling density for hyperspectral microscopy
Gao, L., Kester, R. T., Hagen, N., & Tkaczyk, T. S. (2010) · Optics Express · doi:10.1364/oe.18.014330 · Cited by 241
Clearing Up the Signal: Spectral Imaging and Linear Unmixing in Fluorescence Microscopy
Zimmermann, T., Marrison, J., Hogg, K., & O’Toole, P. (2014) · Methods in Molecular Biology · doi:10.1007/978-1-60761-847-8_5 · Cited by 102
“Sample autofluorescence is a persistent problem of fluorescence microscopy when working in tissues, especially in plants [26, 27].”
Background
Metadata
- Authors
- Berg, R. H.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 2004-04-26
- Volume
- 214
- Issue
- 2
- Pages
- 174-181
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2133778935
- Cited by
- 64
- References
- 0
- FWCI
- 3.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.