CoChat

Liver iron content assessment by routine and simple magnetic resonance imaging procedure in highly transfused patients

Rose, Christian, Vandevenne, Philippe, Bourgeois, Emmanuelle, Cambier, Nathalie, Ernst, Olivier · 2006 · European Journal of Haematology
Cited by 84

The DOI matches its Crossref record.

Abstract

Background: Liver iron content (LIC) assessment by magnetic resonance imaging (MRI) is validated but not standardized. In a single center, we tried to assess the accuracy of a specific, simple MRI procedure adapted to high LIC from a well‐established simple and routine procedure known to quantify LIC. Methods: In 27 cases of monthly transfused patients, we compared biochemical values of LIC assessed on liver biopsy specimens and results obtained by two signal intensity ratio of gradient echo imaging (R2*) MRI protocols. The first was Gandon's routine procedure previously validated in liver disease and the second, our own method, was an addition of a gradient echo sequence specifically adapted to high LIC encountered in hematology practice. Results: Twenty‐seven liver biopsies were performed in 18 adult patients (myelodysplastic syndrome = 5, β‐thalassemia = 13). LIC by biopsy ranged from 1.4 to 54 mg/g liver dry weight (mg/g dw) (median 9.4 mg/g dw). Correlation between LIC by biopsy and by MRI with Gandon's procedure was good (R = 0.80) in patients with LIC falling within the range reported by Gandon. By contrast, a weak correlation was demonstrated (R = 0.52) in patients with high LIC (above 11.2 mg/g dw). With our sequences, the correlation was good both in the entire group of patients (R = 0.83) and in patients with LIC above 11.2 mg/g dw (R = 0.85). Conclusion: Our results suggest that the addition of a specific shorter‐gradient echo sequence to a very simple, fast technique produces an accurate estimation of LIC in post‐transfusional iron overload.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.0902-4441.2006.t01-1-ejh2571.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 84

Metadata

Authors
Rose, C., Vandevenne, P., Bourgeois, E., Cambier, N., & Ernst, O.
Venue
European Journal of Haematology
Publisher
Wiley
Published
2006-04-11
Volume
77
Issue
2
Pages
145-149
ISSN
  • 0902-4441 (ISSN-L)
  • 1600-0609
OpenAlex
W2060225015
Cited by
84
References
0
FWCI
2.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Liver iron content assessment by routine and simple magnetic resonance imaging procedure in highly transfused patients. https://app.cochat.ai/papers/10.1111/j.0902-4441.2006.t01-1-ejh2571.x
The paper
Rose, C., Vandevenne, P., Bourgeois, E., Cambier, N., & Ernst, O. (2006). Liver iron content assessment by routine and simple magnetic resonance imaging procedure in highly transfused patients. European Journal of Haematology. https://doi.org/10.1111/j.0902-4441.2006.t01-1-ejh2571.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.