Self transglutaminase‐based rapid coeliac disease antibody detection by a lateral flow method
Open accessThe DOI matches its Crossref record.
Abstract
Summary: Background: The conventional coeliac disease antibody tests require patient's sera, and are laborious and time‐consuming. Aim: To evaluate a newly developed rapid whole blood test in coeliac disease antibody detection, and its suitability for office use. Methods: Endogenous tissue transglutaminase found in red blood cells in a whole blood fingertip or venous sample is liberated upon haemolysis and complexes with tissue transglutaminase antibodies, if present. The complexes, captured by a lateral flow system, are visualized within 5 min. Stored samples from 121 untreated, 106 treated coeliac disease patients and 107 controls were evaluated and compared with serum endomysium and tissue transglutaminase antibody tests and histology; 150 patients were prospectively tested on site in the doctor's office. Results: The rapid test showed sensitivity (96.7%) comparable with the serum endomysium and tissue transglutaminase antibody tests from stored samples; specificity was slightly lower (93.5%). When tested on site the results were concordant in 96.7% of cases compared with endomysium and tissue transglutaminase antibody results. The test recognized the disappearance of tissue transglutaminase antibodies on a gluten‐free diet. Conclusions: The self tissue transglutaminase‐based rapid test can be easily carried out from a fingertip blood sample on site in the physician's office for both coeliac disease case finding and dietary monitoring purposes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Husby, S., Koletzko, S., Korponay‐Szabó, I. R., Mearin, M. L., Phillips, A., Shamir, R., Troncone, R., Giersiepen, K., Branski, D., Catassi, C., et al. (2012) · Journal of Pediatric Gastroenterology and Nutrition · doi:10.1097/mpg.0b013e31821a23d0 · Cited by 2,683
“Anti-TG2 antibody detection also can be done from the blood at the point of contact using rapid test kits (POC test) (57,66,67), but only as a semiquantitative test for circulating antibodies.”
Self-citationGreen, P. H. R., & Cellier, C. (2007) · New England Journal of Medicine · doi:10.1056/nejmra071600 · Cited by 1,625
Ludvigsson, J. F., Bai, J. C., Biagi, F., Card, T. R., Ciacci, C., Ciclitira, P. J., Green, P. H. R., Hadjivassiliou, M., Holdoway, A., van Heel, D. A., et al. (2014) · Gut · doi:10.1136/gutjnl-2013-306578 · Cited by 1,116
Self-citationFasano, A., & Catassi, C. (2012) · New England Journal of Medicine · doi:10.1056/nejmcp1113994 · Cited by 687
World Gastroenterology Organisation Global Guidelines on Celiac Disease
Bai, J. C., Fried, M., Corazza, G. R., Schuppan, D., Farthing, M., Catassi, C., Greco, L., Cohen, H., Ciacci, C., Eliakim, R., et al. (2013) · Journal of Clinical Gastroenterology · doi:10.1097/mcg.0b013e31827a6f83 · Cited by 262
Metadata
- Authors
- RAIVIO, T., KAUKINEN, K., NEMES, É., LAURILA, K., COLLIN, P., KOVÁCS, J. B., MÄKI, M., & KORPONAY‐SZABÓ, I. R.
- Venue
- Alimentary Pharmacology & Therapeutics
- Publisher
- Wiley
- Published
- 2006-06-16
- Volume
- 24
- Issue
- 1
- Pages
- 147-154
- ISSN
- 0269-2813 (ISSN-L)
- 1365-2036
- OpenAlex
- W2101195699
- Cited by
- 87
- References
- 0
- FWCI
- 4.10
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Self transglutaminase‐based rapid coeliac disease antibody detection by a lateral flow method. https://app.cochat.ai/papers/10.1111/j.1365-2036.2006.02957.x
- The paper
- RAIVIO, T., KAUKINEN, K., NEMES, É., LAURILA, K., COLLIN, P., KOVÁCS, J. B., MÄKI, M., & KORPONAY‐SZABÓ, I. R. (2006). Self transglutaminase‐based rapid coeliac disease antibody detection by a lateral flow method. Alimentary Pharmacology & Therapeutics. https://doi.org/10.1111/j.1365-2036.2006.02957.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.