Meta-analysis: the diagnostic yield of chromoendoscopy for detecting dysplasia in patients with colonic inflammatory bowel disease: Meta-analysis: chromoendoscopy for IBD surveillance
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Dysplasia in inflammatory bowel disease (IBD) is often multifocal and flat. Dye spraying is believed to enhance visualisation of subtle mucosal abnormalities. AIM: To perform a meta-analysis of the published studies to compare the diagnostic yield of dysplastic lesions in patients with IBD undergoing surveillance colonoscopy between chromoendoscopy and standard white light endoscopy. METHODS: We searched electronic databases for full journal articles reporting on chromoendoscopy in patients with IBD. Pooled incremental yield of chromoendoscopy over white light endoscopy for dysplasia detection was determined. A fixed effects model was used unless there was significant heterogeneity. Publication bias was assessed using Funnel plots or Egger's test. RESULTS: Six studies involving 1277 patients provided data on a number of dysplastic lesions detected. The difference in yield of dysplasia between chromoendoscopy and white light endoscopy was 7% (95% CI 3.2-11.3) on a per patient analysis with an NNT of 14.3. The difference in proportion of lesions detected by targeted biopsies was 44% (95% CI 28.6-59.1) and flat lesions was 27% (95% CI 11.2-41.9) in favour of chromoendoscopy. CONCLUSIONS: Chromoendoscopy is significantly better than white light endoscopy in detecting dysplasia in patients with colonic IBD. This holds true for all dysplastic lesions, proportion of targeted lesions and proportion of flat lesions detected.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139 · cited 1×
“Statistical heterogeneity was also measured by the I(2) statistic that quantifies the proportion of inconsistency in individual studies that cannot be explained by chance.(15) Values of I(2) equal to 25%, 50% and 75% represent low, moderate and high heterogeneity, respectively.”
Bias in meta-analysis detected by a simple, graphical test
Egger, M., Smith, G. D., Schneider, M., & Minder, C. (1997) · BMJ · doi:10.1136/bmj.315.7109.629 · Cited by 56,722 · cited 2×
“To test for publication bias we used a test for asymmetry of the funnel plot proposed by Egger et al.(16) This test detects funnel plot asymmetry by determining whether the intercept deviates significantly from zero in a regression of the normalised effect estimate (estimate divided by the standard error) again precis…”
Meta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552 · cited 1×
“A fixed effects model was used unless there was significant heterogeneity, in which case the DerSimonian-Laird random effects model was used.(13) Comprehensive Meta-Analysis version 2.”
The combination of estimates from different experiments
Cochran, W. G. (1954) · Biometrics · doi:10.2307/3001666 · Cited by 5,380
Whiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
How should meta‐regression analyses be undertaken and interpreted?
Thompson, S. G., & Higgins, J. P. T. (2002) · Statistics in Medicine · doi:10.1002/sim.1187 · Cited by 3,026
The risk of colorectal cancer in ulcerative colitis: a meta-analysis
Eaden, J. A., Abrams, K. R., & Mayberry, J. F. (2001) · Gut · doi:10.1136/gut.48.4.526 · Cited by 2,959 · cited 2×
“Patients with ulcerative colitis (UC) have an increased risk for colorectal cancer (CRC) compared to the general population.(1) Cancer in UC occurs at a younger age and increases with time, approaching 18% after 30 years of disease.”
Kornbluth, A., & Sachar, D. B. (2010) · American Journal of Gastroenterology · doi:10.1038/ajg.2009.727 · Cited by 2,023
Guidelines for the management of inflammatory bowel disease in adults
Carter, M. J., Lobo, A. J., & Travis, S. P. L. (2004) · Gut · doi:10.1136/gut.2004.043372 · Cited by 1,083
Kiesslich, R., Fritsch, J., Holtmann, M., Koehler, H. H., Stolte, M., Kanzler, S., Nafe, B., Jung, M., Galle, P. R., & Neurath, M. F. (2003) · Gastroenterology · doi:10.1053/gast.2003.50146 · Cited by 861 · cited 4×
“The magnifying endoscopes used in the Kiesslich et al.(19) study (Pentax Zoom EC3831 FZ, Hamburg, Germany and Olympus Q160 ZI, Hamburg, Germany) and Hurlstone et al.”
InfluentialDNA aneuploidy in colonic biopsies predicts future development of dysplasia in ulcerative colitis
Rubin, C. E., Haggitt, R. C., Burmer, G. C., Brentnall, T. A., Stevens, A. C., Levine, D. S., Dean, P. J., Kimmey, M., Perera, D. R., & Rabinovitch, P. S. (1992) · Gastroenterology · doi:10.1016/0016-5085(92)91185-7 · Cited by 568
Kiesslich, R., Goetz, M., Lammersdorf, K., Schneider, C., Burg, J., Stolte, M., Vieth, M., Nafe, B., Galle, P. R., & Neurath, M. F. (2007) · Gastroenterology · doi:10.1053/j.gastro.2007.01.048 · Cited by 531
Pancolonic indigo carmine dye spraying for the detection of dysplasia in ulcerative colitis
Rutter, M. D., Saunders, B. P., Schofield, G., Forbes, A., Price, A. B., & Talbot, I. C. (2004) · Gut · doi:10.1136/gut.2003.016386 · Cited by 520 · cited 3×
“The addition of endomicroscopy to the CE protocol has been shown to reduce the need for biopsies by 90% and may be the way forward in improving the yield from individual biopsies.(24) Three of the six included studies used methylene blue for the dye spray.”
InfluentialDiagnosis and management of dysplasia in patients with inflammatory bowel diseases
Itzkowitz, S. H., & Harpaz, N. (2004) · Gastroenterology · doi:10.1053/j.gastro.2004.03.025 · Cited by 423 · cited 1×
“The focus of dysplasia in UC is flat and multifocal and can be easily overlooked with conventional white light endoscopy.(6) There is growing evidence that the yield of surveillance can be improved by addition of newer endoscopic methods that enhance the detection of subtle mucosal abnormalities like chromoendoscopy (…”
Most dysplasia in ulcerative colitis is visible at colonoscopy
Rutter, M. D., Saunders, B. P., Wilkinson, K. H., Kamm, M. A., Williams, C. B., & Forbes, A. (2004) · Gastrointestinal Endoscopy · doi:10.1016/s0016-5107(04)01710-9 · Cited by 315
Dekker, E., van den Broek, F., Reitsma, J., Hardwick, J., Offerhaus, G., van Deventer, S., Hommes, D., & Fockens, P. (2007) · Endoscopy · doi:10.1055/s-2007-966214 · Cited by 309 · cited 1×
“Narrow band imaging which could offer similar enhancement of the mucosal detail has not been shown to be better than conventional colonoscopy for detection of dysplasia.(25)”
Marion, J. F., Waye, J. D., Present, D. H., Israel, Y., Bodian, C., Harpaz, N., Chapman, M., Itzkowitz, S., Steinlauf, A. F., Abreu, M. T., et al. (2008) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2008.01934.x · Cited by 287
Hurlstone, D., Sanders, D., Lobo, A., McAlindon, M., & Cross, S. (2005) · Endoscopy · doi:10.1055/s-2005-921032 · Cited by 264 · cited 4×
“study (Pentax Zoom EC3831 FZ, Hamburg, Germany and Olympus Q160 ZI, Hamburg, Germany) and Hurlstone et al.(20) study (Olympus C240Z, Keymed, UK) were all standard definition scopes.”
Influentialvan den Broek, F. J. C., Fockens, P., van Eeden, S., Reitsma, J. B., Hardwick, J. C. H., Stokkers, P. C. F., & Dekker, E. (2008) · Gut · doi:10.1136/gut.2007.144097 · Cited by 249 · cited 1×
“There is growing evidence that the yield of surveillance can be improved by addition of newer endoscopic methods that enhance the detection of subtle mucosal abnormalities like chromoendoscopy (CE) and autofluorescence with narrow band imaging.(7) CE refers to the topical application of dyes or pigments to improve det…”
Are dysplasia and colorectal cancer endoscopically visible in patients with ulcerative colitis?
Rubin, D. T., Rothe, J. A., Hetzel, J. T., Cohen, R. D., & Hanauer, S. B. (2007) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2006.09.025 · Cited by 247
How gastroenterologists screen for colonic cancer in ulcerative colitis: an analysis of performance
Eaden, J. A., Ward, B. A., & Mayberry, J. F. (2000) · Gastrointestinal Endoscopy · doi:10.1016/s0016-5107(00)70405-6 · Cited by 203
Rhun, M. L., Coron, E., Parlier, D., Nguyen, J., Canard, J. M., Alamdari, A., Sautereau, D., Chaussade, S., & Galmiche, J. (2006) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2005.12.009 · Cited by 143
Hüneburg, R., Lammert, F., Rabe, C., Rahner, N., Kahl, P., Büttner, R., Propping, P., Sauerbruch, T., & Lamberti, C. (2009) · Endoscopy · doi:10.1055/s-0028-1119628 · Cited by 130
Hurlstone, D. P., Sanders, D. S., Atkinson, R., Hunter, M. D., McAlindon, M. E., Lobo, A., Cross, S. S., & Thomson, M. A. (2006) · Gut · doi:10.1136/gut.2006.106294 · Cited by 127 · cited 1×
“11 This has in turn led to increasing use of endoscopic resection techniques to treat areas of raised, visible dysplasia in patients with UC, without the need for colectomy.(12) There is therefore a need to improve detection techniques during surveillance endoscopy and CE has been advocated as a promising method.”
Buchner, A. M., Shahid, M. W., Heckman, M. G., McNeil, R. B., Cleveland, P. W., Gill, K. R., Schore, A. N., Ghabril, M., Raimondo, M., Gross, S. A., et al. (2009) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2009.11.009 · Cited by 121 · cited 1×
“improve the detection of colonic polyps during routine colonoscopy.(26) The utility of high definition endoscopes in detecting dysplastic lesions during surveillance of ulcerative colitis has not been studied so far.”
Cited by
Ordás, I., Eckmann, L., Talamini, M., Baumgart, D. C., & Sandborn, W. J. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60150-0 · Cited by 2,078
Magro, F., Gionchetti, P., Eliakim, R., Ardizzone, S., Armuzzi, A., Barreiro-de Acosta, M., Burisch, J., Gecse, K. B., Hart, A. L., Hindryckx, P., et al. (2017) · Journal of Crohn's and Colitis · doi:10.1093/ecco-jcc/jjx008 · Cited by 1,910
Maaser, C., Sturm, A., Vavricka, S. R., Kucharzik, T., Fiorino, G., Annese, V., Calabrese, E., Baumgart, D. C., Bettenworth, D., Borralho Nunes, P., et al. (2019) · Journal of Crohn's and Colitis · doi:10.1093/ecco-jcc/jjy113 · Cited by 1,823
ACG Clinical Guideline: Management of Crohn's Disease in Adults
Lichtenstein, G. R., Loftus, E. V., Isaacs, K. L., Regueiro, M. D., Gerson, L. B., & Sands, B. E. (2018) · American Journal of Gastroenterology · doi:10.1038/ajg.2018.27 · Cited by 1,421
Primary sclerosing cholangitis – a comprehensive review
Karlsen, T. H., Folseraas, T., Thorburn, D., & Vesterhus, M. (2017) · Journal of Hepatology · doi:10.1016/j.jhep.2017.07.022 · Cited by 868
Metadata
- Authors
- Subramanian, V., Mannath, J., Ragunath, K., & Hawkey, C. J.
- Venue
- Alimentary Pharmacology & Therapeutics
- Publisher
- Wiley
- Published
- 2010-12-05
- Volume
- 33
- Issue
- 3
- Pages
- 304-312
- ISSN
- 0269-2813 (ISSN-L)
- OpenAlex
- W1643532405
- Cited by
- 239
- References
- 25
- FWCI
- 5.70
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.