The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Induction and maintenance of propofol anaesthesia: A manual infusion scheme
Abstract
Summary: A simple, manually controlled infusion scheme for continuous administration of propofol was derived by simulation of a computer algorithm designed to achieve a predetermined blood concentration of propofol within 2 minutes and to maintain a constant blood level for the duration of surgery. The manual infusion scheme for a target blood propofol concentration of 3 μg/ml, consisted of a loading dose of 1 mg/kg followed immediately by an infusion of 10 mg/kg/hour for 10 minutes, 8 mg/kg/hour for the next 10 minutes and 6 mg/kg/hour thereafter. An overall mean blood propofol concentration of 3.67 μg/ml was achieved within 2 minutes and maintained stable for the subsequent 80–90 minutes of surgery. The decrease of systolic and diastolic arterial pressures at induction was much less than that previously described after larger induction doses of propofol and there was a negligible haemodynamic response to largyngoscopy and intubation or to the subsequent surgery. The quality of induction and maintenance of anaesthesia was satisfactory in every patient.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Plummer, G. F. (1987) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/0378-4347(87)80394-8 · Cited by 294
CUMMINGS, G. C., DIXON, J., KAY, N. H., WINDSOR, J. P. W., MAJOR, E., MORGAN, M., SEAR, J. W., SPENCE, A. A., & STEPHENSON, D. K. (1984) · Anaesthesia · doi:10.1111/j.1365-2044.1984.tb06425.x · Cited by 166
Self-citationContinous intravenous infusion and multicompartment accumulation
Krüger‐Thiemer, E. (1968) · European Journal of Pharmacology · doi:10.1016/0014-2999(68)90100-3 · Cited by 140
Rapidly achieved plasma concentration plateaus, with observations on theophylline kinetics
Mitenko, P. A., & OGILVIE, R. I. (1972) · Clinical Pharmacology & Therapeutics · doi:10.1002/cpt1972133329 · Cited by 114
Cited by
COMPARISON OF PROPOFOL AND MIDAZOLAM FOR SEDATION IN CRITICALLY ILL PATIENTS
Aitkenhead, A., Willatts, S., Park, G., Collins, C., Ledingham, I., Pepperman, M., David Coates, P., Bodenham, A., Smith, M., & Wallace, P. M. (1989) · The Lancet · doi:10.1016/s0140-6736(89)90770-8 · Cited by 213
Simulation of propofol anaesthesia for intracranial decompression using brain hypothermia treatment
Gaohua, L., & Kimura, H. (2007) · Theoretical Biology and Medical Modelling · doi:10.1186/1742-4682-4-46 · Cited by 6
Metadata
- Authors
- ROBERTS, F. L., DIXON, J., LEWIS, G. T. R., TACKLEY, R. M., & PRYS‐ROBERTS, C.
- Venue
- Anaesthesia
- Publisher
- Wiley
- Published
- 1988-03
- Volume
- 43
- Issue
- s1
- Pages
- 14-17
- ISSN
- 0003-2409 (ISSN-L)
- 1365-2044
- OpenAlex
- W1846667020
- Cited by
- 324
- References
- 4
- FWCI
- 12.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Induction and maintenance of propofol anaesthesia: A manual infusion scheme. https://app.cochat.ai/papers/10.1111/j.1365-2044.1988.tb09061.x
- The paper
- ROBERTS, F. L., DIXON, J., LEWIS, G. T. R., TACKLEY, R. M., & PRYS‐ROBERTS, C. (1988). Induction and maintenance of propofol anaesthesia: A manual infusion scheme. Anaesthesia. https://doi.org/10.1111/j.1365-2044.1988.tb09061.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.