CoChat

Pulse oximeter probes A comparison between finger, nose, ear and forehead probes under conditions of poor perfusion*

Open access
CLAYTON, D. G., WEBB, R. K., RALSTON, A. C., DUTHIE, D., RUNCIMAN, W. B. · 1991 · Anaesthesia
Cited by 90

The DOI matches its Crossref record.

Abstract

Summary: The performances of 10 pulse oximeters using finger probes were compared with the same pulse oximeters using alternative probes (eight finger probes, two nose probes and a forehead probe) in poorly perfused patients. All readings were then compared with directly measured arterial blood oxygen saturations. The mean difference (bias, ‘accuracy’), standard deviation (precision) and ‘drop out’ rate for each pulse oximeter combination was determined. An overall ranking of performance of each pulse oximeter was calculated using five criteria (accuracy, precision, number of readings within 3% of standard, percentage of readings given within 3% of standard, expected overread limit in 95% of cases). Nose and forehead probes performed poorly. Some ear probes performed well compared to some finger probes, but the overall performance of probes in other sites compared to finger probes was worse, (p = 0.05). Two of eight ear probes and no nose or forehead probes would be expected to be within 4% of the reference value in 95% of readings. The use of finger probes rather than probes in other sites is recommended in the patient with poor peripheral perfusion.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2044.1991.tb11492.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 90

Metadata

Authors
CLAYTON, D. G., WEBB, R. K., RALSTON, A. C., DUTHIE, D., & RUNCIMAN, W. B.
Venue
Anaesthesia
Publisher
Wiley
Published
1991-04
Volume
46
Issue
4
Pages
260-265
ISSN
  • 0003-2409 (ISSN-L)
  • 1365-2044
OpenAlex
W2025618716
Cited by
90
References
0
FWCI
1.70
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pulse oximeter probes A comparison between finger, nose, ear and forehead probes under conditions of poor perfusion*. https://app.cochat.ai/papers/10.1111/j.1365-2044.1991.tb11492.x
The paper
CLAYTON, D. G., WEBB, R. K., RALSTON, A. C., DUTHIE, D., & RUNCIMAN, W. B. (1991). Pulse oximeter probes A comparison between finger, nose, ear and forehead probes under conditions of poor perfusion*. Anaesthesia. https://doi.org/10.1111/j.1365-2044.1991.tb11492.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.