The DOI matches its Crossref record.
A comparison of Plasmalyte 148 and 0.9% saline for intra‐operative fluid replacement
Open accessAbstract
Summary: Thirty patients undergoing major hepatobiliary or pancreatic surgery were randomly allocated to receive either 0.9% saline or Plasmalyte 148 (a balanced salt solution), at 15 ml.kg ‐1 .h ‐1 . Arterial blood gas analysis was performed before and after surgery. Plasma biochemistry (Na + , K + , Cl ‐ , lactate) measurements were made before and after surgery and at 24 h after surgery. The patients receiving 0.9% saline had significantly increased chloride concentrations (p < 0.01), decreased standard bicarbonate concentrations (p < 0.01) and increased base deficit (p < 0.01) compared to those receiving Plasmalyte 148. There were no significant changes in plasma sodium or potassium or blood lactate concentrations in either group. The exclusive use of 0.9% saline intra‐operatively can produce a temporary hyperchloraemic acidosis which could be given false pathological significance. In addition it may exacerbate an acidosis resulting from an actual pathological stale. The use of a balanced salt solution such as Plasmalyte 148 may avoid these complications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chowdhury, A. H., Cox, E. F., Francis, S. T., & Lobo, D. N. (2012) · Annals of Surgery · doi:10.1097/sla.0b013e318256be72 · Cited by 764
Shaw, A. D., Bagshaw, S. M., Goldstein, S. L., Scherer, L. A., Duan, M., Schermer, C. R., & Kellum, J. A. (2012) · Annals of Surgery · doi:10.1097/sla.0b013e31825074f5 · Cited by 668
Wilkes, N. J., Woolf, R., Mutch, M., Mallett, S. V., Peachey, T., Stephens, R., & Mythen, M. G. (2001) · Anesthesia & Analgesia · doi:10.1097/00000539-200110000-00003 · Cited by 461
O???Malley, C. M. N., Frumento, R. J., Hardy, M. A., Benvenisty, A. I., Brentjens, T. E., Mercer, J. S., & Bennett-Guerrero, E. (2005) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000150939.28904.81 · Cited by 410
Raghunathan, K., Shaw, A., Nathanson, B., Stürmer, T., Brookhart, A., Stefan, M. S., Setoguchi, S., Beadles, C., & Lindenauer, P. K. (2014) · Critical Care Medicine · doi:10.1097/ccm.0000000000000305 · Cited by 404
Metadata
- Authors
- McFARLANE, C., & LEE, A.
- Venue
- Anaesthesia
- Publisher
- Wiley
- Published
- 1994-09
- Volume
- 49
- Issue
- 9
- Pages
- 779-781
- ISSN
- 0003-2409 (ISSN-L)
- 1365-2044
- OpenAlex
- W2061863854
- Cited by
- 233
- References
- 0
- FWCI
- 2.06
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A comparison of Plasmalyte 148 and 0.9% saline for intra‐operative fluid replacement. https://app.cochat.ai/papers/10.1111/j.1365-2044.1994.tb04450.x
- The paper
- McFARLANE, C., & LEE, A. (1994). A comparison of Plasmalyte 148 and 0.9% saline for intra‐operative fluid replacement. Anaesthesia. https://doi.org/10.1111/j.1365-2044.1994.tb04450.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.