The development of ‘Diprifusor’: a TCI system for propofol
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
The ‘Diprifusor’ target controlled infusion system has been developed as a standardised infusion system for the administration of propofol by target controlled infusion. A preferred set of pharmacokinetic parameters for propofol was selected using computer simulation of a known infusion scheme with pharmacokinetic parameters described in published literature. The selected model was included in a ‘Diprifusor’ module that was interfaced with, and later incorporated into, a computer‐compatible infusion pump. Clinical trials with such systems led to guidance on appropriate target concentrations for the administration of propofol by ‘Diprifusor’ target controlled infusion for inclusion in drug prescribing information. Standardisation of the delivery performance (± 5%) of commercial systems has been achieved with a laboratory performance specification. Clinical studies indicate that the actual blood concentrations achieved were about 16% greater than the calculated values displayed by the system. In an individual patient, titration of the target concentration is required in the same manner as an anaesthetic vapouriser is adjusted to obtain a specific pharmacodynamic effect.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PHARMACOKINETIC MODEL DRIVEN INFUSION OF PROPOFOL IN CHILDREN
MARSH, B., WHITE, M., MORTON, N., & KENNY, G. N. C. (1991) · British Journal of Anaesthesia · doi:10.1093/bja/67.1.41 · Cited by 1,168
European Journal of Clinical Pharmacology
(2013) · European Journal of Clinical Pharmacology · doi:10.1007/228.1432-1041 · Cited by 608
Plummer, G. F. (1987) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/0378-4347(87)80394-8 · Cited by 294
Intravenous propofol anaesthesia using a computerised infusion system
White, M., & Kenny, G. N. C. (1990) · Anaesthesia · doi:10.1111/j.1365-2044.1990.tb14685.x · Cited by 146
Effective concentration 50 for propofol with and without 67% nitrous oxide
DAVIDSON, J. A. H., MacLeod, A. D., Howie, J. C., WHITE, M., & Kenny, G. N. C. (1993) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1993.tb03746.x · Cited by 130
COMPUTER CONTROLLED INFUSION OF PROPOFOL
Tackley, R. M., Lewis, G. T. R., Roberts, C. P., BOADEN, R. W., DIXON, J., & HARVEY, J. T. (1989) · British Journal of Anaesthesia · doi:10.1093/bja/62.1.46 · Cited by 124
Cited by
Pharmacokinetic–pharmacodynamic model for propofol for broad application in anaesthesia and sedation
Eleveld, D. J., Colin, P., Absalom, A. R., & Struys, M. M. R. F. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2018.01.018 · Cited by 302
Propofol sedation with a target-controlled infusion pump in elderly patients undergoing ERCP
Ogawa, T., Tomoda, T., Kato, H., Akimoto, Y., Tanaka, S., & Okada, H. (2020) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2020.03.002 · Cited by 50
Metadata
- Authors
- Glen, J. B.
- Venue
- Anaesthesia
- Publisher
- Wiley
- Published
- 1998-04
- Volume
- 53
- Issue
- s1
- Pages
- 13-21
- ISSN
- 0003-2409 (ISSN-L)
- 1365-2044
- OpenAlex
- W1517740119
- Cited by
- 193
- References
- 6
- FWCI
- 9.85
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.