Initial anatomic investigations of the I‐gel airway: a novel supraglottic airway without inflatable cuff*
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Summary: The I‐gel airway is a novel supraglottic airway that uses an anatomically designed mask made of a gel‐like thermoplastic elastomer. We studied the positioning and mechanics of this new device in 65 non‐embalmed cadavers with 73 endoscopies (eight had repeat insertion), 16 neck dissections, and six neck radiographs. A full view of the glottis (percentage of glottic opening score 100%) occurred in 44/73 insertions, whereas only 3/73 insertions had epiglottis‐only views. Including the eight repeat insertions with a different size, a glottic opening score of > 50% was obtained in all 65 cadavers. The mean percentage of glottic opening score for the 73 insertions was 82% (95% confidence interval 75–89%). In each of the neck dissections and radiographs the bowl of the device covered the laryngeal inlet. We found that the I‐gel effectively conformed to the perilaryngeal anatomy despite the lack of an inflatable cuff and it consistently achieved proper positioning for supraglottic ventilation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assessment of Airway Visualization: Validation of the Percentage of Glottic Opening (POGO) Scale
Levitan, R. M., Ochroch, E. A., Rush, S., Shofer, F. S., & Hollander, J. E. (1998) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.1998.tb02823.x · Cited by 279 · cited 1×
“Laryngeal view was evaluated (by the second author) using a percentage of glottic opening score [ 10 ].”
MethodSelf-citationUse of a new videolaryngoscope (GlideScope®) in the management of a difficult airway
Cooper, R. M. (2003) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/bf03018651 · Cited by 244
Assessment of laryngeal view: Percentage of glottic opening scorevs Cormack and Lehane grading
Ochroch, E. A., Hollander, J. E., Kush, S., Shofer, F. S., & Levitan, R. M. (1999) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/bf03013137 · Cited by 198
Self-citationA Comparison of the Disposable Versus the Reusable Laryngeal Mask Airway in Paralyzed Adult Patients
Brimacombe, J. R., KELLER, C., Morris, R., & Mecklem, D. (1998) · Anesthesia & Analgesia · doi:10.1097/00000539-199810000-00033 · Cited by 76
Miller, D. M., & Lavelle, M. (2002) · Anesthesia & Analgesia · doi:10.1097/00000539-200203000-00052 · Cited by 19 · cited 1×
“The SLIPA, or Streamlined Liner of the Pharynx Airway, is also anatomically preshaped and does not use an inflatable cuff [ 13 , 14].”
Method
Cited by
Frerk, C., Mitchell, V. S., McNarry, A. F., Mendonca, C., Bhagrath, R., Patel, A., O’Sullivan, E. P., Woodall, N. M., & Ahmad, I. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aev371 · Cited by 2,214
Myatra, S. N., Shah, A., Kundra, P., Patwa, A., Ramkumar, V., Divatia, J. V., Raveendra, U. S., Shetty, S. R., Ahmed, S. M., Doctor, J. R., et al. (2016) · Indian Journal of Anaesthesia · doi:10.4103/0019-5049.195481 · Cited by 294
Theiler, L. G., Kleine-Brueggeney, M., Kaiser, D., Urwyler, N., Luyet, C., Vogt, A., Greif, R., & Unibe, M. M. E. (2009) · Anesthesiology · doi:10.1097/aln.0b013e3181a4c6b9 · Cited by 167
Metadata
- Authors
- Levitan, R. M., & Kinkle, W. C.
- Venue
- Anaesthesia
- Publisher
- Wiley
- Published
- 2005-08-19
- Volume
- 60
- Issue
- 10
- Pages
- 1022-1026
- ISSN
- 0003-2409 (ISSN-L)
- 1365-2044
- OpenAlex
- W2097615318
- Cited by
- 235
- References
- 5
- FWCI
- 5.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.