Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 279

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Assessment of Airway Visualization: Validation of the Percentage of Glottic Opening (POGO) Scale

Levitan, Richard M., Ochroch, E. Andrew, Rush, Scott, Shofer, Frances S., Hollander, Judd E. · 1998 · Academic Emergency Medicine

Abstract

Objective: Research defining optimal methods of intubation has been limited by the lack of a validated outcome measure to assess airway visualization. The objective of this study was to develop a reliable scale for the assessment of airway visualization during endotracheal intubation. Methods: This prospective study was performed to assess the intra‐ and interphysician reliabilities of emergency physicians (EPs) for estimating the percentage of glottic opening (POGO) that is visualized during direct laryngoscopy. Using video images of laryngeal views obtained from a commercially available videotape, still slide images were prepared representing glottic openings ranging from 0% to 100%. Five EPs, blinded to study objective, reviewed 25 pairs of airway slides (50 slides total). For each slide, the physicians recorded the POGO and their scores using a modified Cormack‐Lehane (MCL) scale, where grade I is a view of the full glottic opening, MCL grade II is a partial view of the glottic opening, and MCL grade III is a view of the epiglottis only. Inter‐ and intraphysician reliabilities were assessed using the kappa statistic (K) for MCL grade and intraclass correlation coefficient for the POGO scores. Results: For the POGO score, the degree of intrarater reliability was very good, with an intraphysician correlation of 0.85 and an interphysician correlation of 0.74. For the MCL score, the intraphysician concordance had a K of 0.71, and interphysician concordance was also good, with a K of 0.59. Conclusion: Both the modified version of the Cormack‐Lehane grading classification and the POGO score have good interphysician and intraphysician reliabilities. Because the POGO score can distinguish patients with large and small degrees of partial glottic visibility, it might provide a better outcome for assessing the difference between various intubation techniques.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1553-2712.1998.tb02823.x

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 279

Metadata

Authors
Levitan, R. M., Ochroch, E. A., Rush, S., Shofer, F. S., & Hollander, J. E.
Venue
Academic Emergency Medicine
Publisher
Wiley
Published
1998-09
Volume
5
Issue
9
Pages
919-923
ISSN
  • 1069-6563 (ISSN-L)
  • 1553-2712
OpenAlex
W2054999643
Cited by
279
References
4
FWCI
3.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of Airway Visualization: Validation of the Percentage of Glottic Opening (POGO) Scale. https://app.cochat.ai/papers/10.1111/j.1553-2712.1998.tb02823.x
The paper
Levitan, R. M., Ochroch, E. A., Rush, S., Shofer, F. S., & Hollander, J. E. (1998). Assessment of Airway Visualization: Validation of the Percentage of Glottic Opening (POGO) Scale. Academic Emergency Medicine. https://doi.org/10.1111/j.1553-2712.1998.tb02823.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.