The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Assessment of Airway Visualization: Validation of the Percentage of Glottic Opening (POGO) Scale
Abstract
Objective: Research defining optimal methods of intubation has been limited by the lack of a validated outcome measure to assess airway visualization. The objective of this study was to develop a reliable scale for the assessment of airway visualization during endotracheal intubation. Methods: This prospective study was performed to assess the intra‐ and interphysician reliabilities of emergency physicians (EPs) for estimating the percentage of glottic opening (POGO) that is visualized during direct laryngoscopy. Using video images of laryngeal views obtained from a commercially available videotape, still slide images were prepared representing glottic openings ranging from 0% to 100%. Five EPs, blinded to study objective, reviewed 25 pairs of airway slides (50 slides total). For each slide, the physicians recorded the POGO and their scores using a modified Cormack‐Lehane (MCL) scale, where grade I is a view of the full glottic opening, MCL grade II is a partial view of the glottic opening, and MCL grade III is a view of the epiglottis only. Inter‐ and intraphysician reliabilities were assessed using the kappa statistic (K) for MCL grade and intraclass correlation coefficient for the POGO scores. Results: For the POGO score, the degree of intrarater reliability was very good, with an intraphysician correlation of 0.85 and an interphysician correlation of 0.74. For the MCL score, the intraphysician concordance had a K of 0.71, and interphysician concordance was also good, with a K of 0.59. Conclusion: Both the modified version of the Cormack‐Lehane grading classification and the POGO score have good interphysician and intraphysician reliabilities. Because the POGO score can distinguish patients with large and small degrees of partial glottic visibility, it might provide a better outcome for assessing the difference between various intubation techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
Difficult tracheal intubation in obstetrics
CORMACK, R. S., & LEHANE, J. (1984) · Anaesthesia · doi:10.1111/j.1365-2044.1984.tb08932.x · Cited by 2,471
PREDICTING DIFFICULT INTUBATION
WILSON, M. E., SPIEGELHALTER, D., ROBERTSON, J. A., & LESSER, P. (1988) · British Journal of Anaesthesia · doi:10.1093/bja/61.2.211 · Cited by 875
The Efficacy of the "BURP" Maneuver During a Difficult Laryngoscopy
Takahata, O., Kubota, M., Mamiya, K., Akama, Y., Nozaka, T., Matsumoto, H., & Ogawa, H. (1997) · Anesthesia & Analgesia · doi:10.1213/00000539-199702000-00033 · Cited by 131
Cited by
Videolaryngoscopy versus direct laryngoscopy for adult patients requiring tracheal intubation
Lewis, S. R., Butler, A. R., Parker, J., Cook, T. M., & Smith, A. F. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011136.pub2 · Cited by 374
Lewis, S. R., Butler, A. R., Parker, J., Cook, T. M., Schofield-Robinson, O. J., & Smith, A. F. (2017) · British Journal of Anaesthesia · doi:10.1093/bja/aex228 · Cited by 359
Predicting difficult intubation–worthwhile exercise or pointless ritual?
(2002) · Anaesthesia · doi:10.1046/j.0003-2409.2001.02515.x · Cited by 280
Kleine-Brueggeney, M., Greif, R., Schoettker, P., Savoldelli, G. L., Nabecker, S., & Theiler, L. G. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aew058 · Cited by 216
Gu, Y., Robert, J., Kovacs, G., Milne, A. D., Morris, I., Hung, O., MacQuarrie, K., Mackinnon, S., & Adam Law, J. (2016) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-016-0654-6 · Cited by 57
Metadata
- Authors
- Levitan, R. M., Ochroch, E. A., Rush, S., Shofer, F. S., & Hollander, J. E.
- Venue
- Academic Emergency Medicine
- Publisher
- Wiley
- Published
- 1998-09
- Volume
- 5
- Issue
- 9
- Pages
- 919-923
- ISSN
- 1069-6563 (ISSN-L)
- 1553-2712
- OpenAlex
- W2054999643
- Cited by
- 279
- References
- 4
- FWCI
- 3.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of Airway Visualization: Validation of the Percentage of Glottic Opening (POGO) Scale. https://app.cochat.ai/papers/10.1111/j.1553-2712.1998.tb02823.x
- The paper
- Levitan, R. M., Ochroch, E. A., Rush, S., Shofer, F. S., & Hollander, J. E. (1998). Assessment of Airway Visualization: Validation of the Percentage of Glottic Opening (POGO) Scale. Academic Emergency Medicine. https://doi.org/10.1111/j.1553-2712.1998.tb02823.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.