Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 188

The DOI matches its Crossref record.

Blood transfusion and the anaesthetist: management of massive haemorrhage

Open access
Thomas, D, Wee, M, Clyburn, P, Walker, I, Brohi, K, Collins, P, Doughty, H, Isaac, J, Mahoney, PF, Shewry, L·2010·Anaesthesia

Abstract

Summary: 1. Hospitals must have a major haemorrhage protocol in place and this should include clinical, laboratory and logistic responses. 2. Immediate control of obvious bleeding is of paramount importance (pressure, tourniquet, haemostatic dressings). 3. The major haemorrhage protocol must be mobilised immediately when a massive haemorrhage situation is declared. 4. A fibrinogen < 1 g.l −1 or a prothrombin time (PT) and activated partial thromboplastin time (aPTT) of > 1.5 times normal represents established haemostatic failure and is predictive of microvascular bleeding. Early infusion of fresh frozen plasma (FFP; 15 ml.kg −1 ) should be used to prevent this occurring if a senior clinician anticipates a massive haemorrhage. 5. Established coagulopathy will require more than 15 ml.kg −1 of FFP to correct. The most effective way to achieve fibrinogen replacement rapidly is by giving fibrinogen concentrate or cryoprecipitate if fibrinogen is unavailable. 6. 1:1:1 red cell:FFP:platelet regimens, as used by the military, are reserved for the most severely traumatised patients. 7. A minimum target platelet count of 75 × 10 9 .l −1 is appropriate in this clinical situation. 8. Group‐specific blood can be issued without performing an antibody screen because patients will have minimal circulating antibodies. O negative blood should only be used if blood is needed immediately. 9. In hospitals where the need to treat massive haemorrhage is frequent, the use of locally developed shock packs may be helpful. 10. Standard venous thromboprophylaxis should be commenced as soon as possible after haemostasis has been secured as patients develop a prothrombotic state following massive haemorrhage.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2044.2010.06538.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 188

Metadata

Authors
Thomas, D., Wee, M., Clyburn, P., Walker, I., Brohi, K., Collins, P., Doughty, H., Isaac, J., Mahoney, P., & Shewry, L.
Venue
Anaesthesia
Publisher
Wiley
Published
2010-10-12
Volume
65
Issue
11
Pages
1153-1161
ISSN
  • 0003-2409 (ISSN-L)
  • 1365-2044
OpenAlex
W1505916620
Cited by
188
References
0
FWCI
9.90
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Blood transfusion and the anaesthetist: management of massive haemorrhage. https://app.cochat.ai/papers/10.1111/j.1365-2044.2010.06538.x
The paper
Thomas, D., Wee, M., Clyburn, P., Walker, I., Brohi, K., Collins, P., Doughty, H., Isaac, J., Mahoney, P., & Shewry, L. (2010). Blood transfusion and the anaesthetist: management of massive haemorrhage. Anaesthesia. https://doi.org/10.1111/j.1365-2044.2010.06538.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.