Skin thickness measurement by pulsed ultrasound; its reproducibility, validation and variability
Abstract
The reproducibility of the pulsed ultrasound technique for the determination of skin thickness was investigated, using two independent observers. No systematic difference was found and a high correlation was obtained. Studies were also undertaken to validate the pulsed ultrasound technique as a measure of true skin thickness. Skin thickness determined in vitro was found to be greater than when in vivo determinations were made by either the pulsed ultrasound or a xeroradiographic technique, probably due to the release of in vivo tension within the dermis after excision. Skin thickness was found to increase linearly with age up to the age of 20 years and to decrease linearly with age subsequently. Differences in skin thickness between the sexes and in different sites of the body were demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Aging decreases the capacity of human skin to produce vitamin D3.
MacLaughlin, J., & Holick, M. F. (1985) · Journal of Clinical Investigation · doi:10.1172/jci112134 · Cited by 1,436
Is grip strength a useful single marker of frailty?
Syddall, H., Cooper, C., Martin, F., Briggs, R., & Aihie Sayer, A. (2003) · Age and Ageing · doi:10.1093/ageing/afg111 · Cited by 564
Structural and functional changes of normal aging skin
Fenske, N. A., & Lober, C. W. (1986) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(86)70208-9 · Cited by 535
Age-related mechanical properties of human skin: An in vivo study
Escoffier, C., de Rigal, J., Rochefort, A., Vasselet, R., Léveˆque, J.-L., & Agache, P. G. (1989) · Journal of Investigative Dermatology · doi:10.1016/0022-202x(89)90058-4 · Cited by 493
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348
Metadata
- Authors
- TAN, C. Y., STATHAM, B., MARKS, R., & PAYNE, P. A.
- Venue
- British Journal of Dermatology
- Publisher
- Oxford University Press (OUP)
- Published
- 1982-06
- Volume
- 106
- Issue
- 6
- Pages
- 657-667
- ISSN
- 0007-0963 (ISSN-L)
- 1365-2133
- OpenAlex
- W2069949406
- Cited by
- 348
- References
- 0
- FWCI
- 6.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Skin thickness measurement by pulsed ultrasound; its reproducibility, validation and variability. https://app.cochat.ai/papers/10.1111/j.1365-2133.1982.tb11680.x
- The paper
- TAN, C. Y., STATHAM, B., MARKS, R., & PAYNE, P. A. (1982). Skin thickness measurement by pulsed ultrasound; its reproducibility, validation and variability. British Journal of Dermatology. https://doi.org/10.1111/j.1365-2133.1982.tb11680.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.