The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
A Simple Method for the Detection of Unstable Haemoglobins
Abstract
S ummary. A simple test is described for the detection of unstable haemoglobins by the addition of haemolysate to an isopropanol/buffer solution at 37°C. Over 200 normal haemolysates have been tested giving no precipitation up to 30 min incubation whilst six samples containing an unstable haemoglobin gave a precipitate within 5 min, which was flocculent by 20 min. As well as being a simple and effective screening test, the procedure is suitable for the purification of unstable haemoglobins for further studies but suffers from limitations, probably in common with the heat precipitation method, in the quantitation of the abnormal haemoglobin. Its use as a research tool is illustrated by comparative measurements of the stabilities of various forms of haemoglobin. These show deoxyhaemoglobin to be considerably more stable than oxyhaemoglobin thus supporting suggested interchain bondings in deoxyhaemoglobin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PERUTZ, M. F. (1970) · Nature · doi:10.1038/228726a0 · Cited by 2,926
Haemoglobin Hammersmith (β 42 (CD1) Phe→Ser)
Dacie, J. V., Shinton, N. K., Gaffney, P. J., Carrell, R. W., & Lehmann, H. (1967) · Nature · doi:10.1038/216663a0 · Cited by 150
Self-citationVARIATIONS IN THE STRUCTURE OF HUMAN HAEMOGLOBIN
Lehmann, H., & Carrell, R. W. (1969) · British Medical Bulletin · doi:10.1093/oxfordjournals.bmb.a070664 · Cited by 139
Self-citation
Cited by
Hemoglobin Variants: Biochemical Properties and Clinical Correlates
Thom, C. S., Dickson, C. F., Gell, D. A., & Weiss, M. J. (2013) · Cold Spring Harbor Perspectives in Medicine · doi:10.1101/cshperspect.a011858 · Cited by 336
“Hemoglobin stability tests measure the propensity for Hb to denature on exposure to various stresses including heat (Carrell and Kay 1972), isopropanol (Bender et al.”
BackgroundCharache, S., Jacobson, R., Brimhall, B., Murphy, E., Hathaway, P., Winslow, R., Jones, R., Rath, C., & Simkovich, J. (1978) · Blood · doi:10.1182/blood.v51.2.331.331 · Cited by 49
Metadata
- Authors
- Carrell, R. W., & Kay, R.
- Venue
- British Journal of Haematology
- Publisher
- Wiley
- Published
- 1972-11
- Volume
- 23
- Issue
- 5
- Pages
- 615-619
- ISSN
- 0007-1048 (ISSN-L)
- 1365-2141
- OpenAlex
- W2116907040
- Cited by
- 489
- References
- 3
- FWCI
- 13.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Simple Method for the Detection of Unstable Haemoglobins. https://app.cochat.ai/papers/10.1111/j.1365-2141.1972.tb07096.x
- The paper
- Carrell, R. W., & Kay, R. (1972). A Simple Method for the Detection of Unstable Haemoglobins. British Journal of Haematology. https://doi.org/10.1111/j.1365-2141.1972.tb07096.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.