Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 381

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Efficacy of standard dose and 30 ml/kg fresh frozen plasma in correcting laboratory parameters of haemostasis in critically ill patients

Open access
Chowdhury, Pratima, Saayman, Anton G., Paulus, Ulrike, Findlay, George P., Collins, Peter W.·2004·British Journal of Haematology

Abstract

Summary: This study assessed the effect on coagulation tests of fresh frozen plasma (FFP), given according to guidelines compared with higher doses in critically ill patients. Group 1 (10 patients) received 12·2 ml/kg and group 2 (12 patients) 33·5 ml/kg FFP. Prothrombin time, activated partial thromboplastin time and factors I–XII were measured before and after FFP infusion. Factor levels of 30 IU/dl (1 g/l for fibrinogen) were considered haemostatic. A retrospective review showed 10 of 22 (five in group 1 and five in group 2) patients had not required FFP. Of those that needed FFP, one of five in group 1 and seven of seven in group 2 had coagulation factor levels above the target post‐FFP. Increments for group 1 versus 2 were: fibrinogen 0·4 vs. 1·0 g/l, FII 16 vs. 41*, FV 10 vs. 28*, FVII 11 vs. 38*, FVIII 10 vs. 17, FIX 8 vs. 28*, FX 15 vs. 37*, FXI 9 vs. 23 and FXII 30 vs. 44 IU/dl* (*P < 0·01). In vivo recovery of coagulation factors was the same for both groups and the observed increments correlated with the dose of FFP. In conclusion, coagulation screens were poor predictors of coagulation factor levels and current guidelines on the use of FFP result in predictably small increments in coagulation factors in critically ill patients and should be reviewed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2141.2004.04868.x

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 381

Metadata

Authors
Chowdhury, P., Saayman, A. G., Paulus, U., Findlay, G. P., & Collins, P. W.
Venue
British Journal of Haematology
Publisher
Wiley
Published
2004-02-27
Volume
125
Issue
1
Pages
69-73
ISSN
  • 0007-1048 (ISSN-L)
  • 1365-2141
OpenAlex
W2042603596
Cited by
381
References
10
FWCI
14.84
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Efficacy of standard dose and 30 ml/kg fresh frozen plasma in correcting laboratory parameters of haemostasis in critically ill patients. https://app.cochat.ai/papers/10.1111/j.1365-2141.2004.04868.x
The paper
Chowdhury, P., Saayman, A. G., Paulus, U., Findlay, G. P., & Collins, P. W. (2004). Efficacy of standard dose and 30 ml/kg fresh frozen plasma in correcting laboratory parameters of haemostasis in critically ill patients. British Journal of Haematology. https://doi.org/10.1111/j.1365-2141.2004.04868.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.