CoChat

Influence of short‐term exposure to airborne Der p 1 and volatile organic compounds on skin barrier function and dermal blood flow in patients with atopic eczema and healthy individuals

Huss‐Marp, J., Eberlein‐König, B., Breuer, K., Mair, S., Ansel, A., Darsow, U., Krämer, U., Mayer, E., Ring, J., Behrendt, H. · 2006 · Clinical & Experimental Allergy
Cited by 106

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Summary: Background Epidemiological studies indicate environmental pollutants to be involved in the increase in the prevalence of allergic diseases. In human exposure studies, volatile organic compounds (VOCs) have been shown to cause exacerbations of allergic asthma whereas, no data concerning atopic eczema (AE) are available. Objective We investigated the effect of airborne VOCs on the skin of patients with AE and controls in the presence or absence of house dust mite allergen, Der p 1. Methods In a double‐blind crossover study, 12 adults with AE and 12 matched healthy volunteers were exposed on their forearms to Der p 1 and subsequently to a mixture of 22 VOCs (M22, 5 mg/m 3) in a total body exposure chamber for 4 h. Transepidermal water loss (TEWL) and skin blood flow were measured in all subjects before, during and after exposure. Additionally, an atopy patch test (APT) with Der p 1 was applied to the skin after exposure. Results A significant increase in transepidermal water loss was observed 48 h after exposure to VOCs as compared with exposure with filtered air in all individuals (mean difference: +34%; 95% Confidence Interval: 7–69%). Prior Der p 1 exposure resulted in a significant rise of dermal blood flow after 48 h in patients with AE but not in controls. Six out of seven patients showed enhanced atopy patch test (APT) reactions to HDM allergen after previous exposure to VOCs. Conclusion Our results show that exposure to VOCs – at concentrations commonly found in indoor environments – can damage the epidermal barrier and enhance the adverse effect of Der p 1 on sensitized subjects with AE. These findings may contribute to a better understanding of the mechanisms underlying the increase in prevalence and exacerbation of AE.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2222.2006.02448.x

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 37

  1. 10.1038/35037000 · DOI · Paper page
  2. 10.1016/S0952-7915(01)00282-5 · DOI · Paper page
  3. 10.1056/NEJM200101113440206 · DOI · Paper page
  4. Levy JI, 1998, Impact of residential nitrogen dioxide exposure on personal exposure, an international study, 48, 553
  5. Tucker WG., 2000, Indoor air quality handbook, 31.1
  6. 10.1034/j.1600-0668.13.s.6.2.x · DOI · Paper page
  7. 10.1046/j.0905-6947.2003.00226.x · doi:10.1046/j.0905-6947.2003.00226.x
  8. 10.1016/S0003-4878(96)00039-7 · DOI
  9. 10.1078/S1438-4639(04)70004-8 · DOI
  10. 10.1078/1438-4639-00100 · DOI
  11. 10.1046/j.0105-4538.2002.00001.x · doi:10.1046/j.0105-4538.2002.00001.x
  12. Wallace LA., 2000, Indoor air quality handbook, 33.1
  13. Stubner P, 2004, A direct comparison of the efficacy of antihistamines in SAR and PAR, randomised, placebo-controlled studies with levocetirizine and loratadine using an environmental exposure unit – the Vienna Challenge Chamber (VCC), 20, 891
  14. Darsow U, 2004, The prevalence of positive reactions in the atopy patch test with aeroallergens and food allergens in subjects with atopic eczema, a European multicenter study, 59, 1318
  15. Mølhave L., 2000, Indoor air quality handbook, 25.1
  16. Huss‐Marp J, 2001, Aerogenic provocation test of skin (APTOS) – a new method to expose the skin with standardized allergen aerosols, J Euro Acad Dermatol, 15, 104
  17. 10.1034/j.1600-0536.2001.450506.x · DOI
  18. Hutter HP, 2002, Volatile organic compounds and formaldehyde in bedrooms, results of a survey in Vienna, Austria, 12, 239
  19. 10.1007/s001030170011 · doi:10.1007/s001030170011
  20. 10.1034/j.1600-0668.2002.120107.x · DOI · Paper page
  21. 10.1055/s-2007-1024338 · doi:10.1055/s-2007-1024338
  22. 10.1016/S0013-9351(05)80140-9 · DOI
  23. 10.1002/(SICI)1097-0029(19970501)37:3<214::AID-JEMT6>3.0.CO;2-N · doi:10.1002/(sici)1097-0029(19970501)37:3<214::aid-jemt6>3.0.co;2-n
  24. 10.1002/jbt.21 · doi:10.1002/jbt.21
  25. 10.1016/S0378-4274(03)00020-1 · DOI
  26. 10.1002/jbt.10065 · DOI
  27. Gordon SM, 1999, Residential environmental measurements in the National Human Exposure Assessment Survey (NHEXAS) pilot study in Arizona, preliminary results for pesticides and VOCs, 9, 456
  28. 2005, Deutsche Forschungsgemeinschaft. List of MAK and BAT values. Maximum concentrations and biological tolerance values at the workplace
  29. 10.1179/oeh.2000.6.1.1 · DOI
  30. Seifert B., 1999, Richtwerte für die Innenraumluft, Die Beurteilung der Innenraumluftqualität mit Hilfe der Summe flüchtiger organischer Verbindungen, 42, 270
  31. 10.1034/j.1600-0668.13.s.6.1.x · DOI
  32. 10.1016/S0091-6749(95)70034-X · DOI
  33. Arbes SJ, 2003, House dust mite allergen in US beds, results from the first National Survey of Lead and Allergens in Housings, 111, 408
  34. Robinson C, 2001, Peptidase allergens, occludins and claudin, do their interactions facilitate the development of hypersensitivity reactions at mucosal surfaces?, 31, 186
  35. Huss‐Marp J, 2005, Handbook of atopic eczema, 371
  36. 10.1016/S0738-081X(02)00370-X · DOI
  37. 10.1016/S1081-1206(10)62332-0 · DOI

Cited by

See all 106

Metadata

Authors
Huss‐Marp, J., Eberlein‐König, B., Breuer, K., Mair, S., Ansel, A., Darsow, U., Krämer, U., Mayer, E., Ring, J., & Behrendt, H.
Venue
Clinical & Experimental Allergy
Publisher
Wiley
Published
2006-02-24
Volume
36
Issue
3
Pages
338-345
ISSN
  • 0954-7894 (ISSN-L)
  • 1365-2222
OpenAlex
W2119516268
Cited by
106
References
7
FWCI
5.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.